1、Designation: D5421 15 An American National StandardStandard Specification forContact Molded “Fiberglass” (Glass-Fiber-ReinforcedThermosetting Resin) Flanges1This standard is issued under the fixed designation D5421; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers circular contact-molded fiber-glass reinforced
3、-thermosetting-resin flanges for use in pipesystems and tank nozzles. Included are requirements formaterials, workmanship, performance, and dimensions.1.2 Flanges (see Fig. 1) may be produced as integral flanges,Type A, or flange-on-pipe, Type B.1.3 This specification is based on flange performance
4、anddoes not cover design.1.4 These flanges are designed for use with pipe and tanksthat are manufactured to Specifications D2996, D2997, D3262,D3299, D3517, D3754, and D4097.1.5 Selection of gaskets is not covered in this specification,refer to the manufacturers recommendation.1.6 The values stated
5、in inch-pound units are to be regardedas the standard. The SI units given in parentheses are forinformation only.1.7 The following precautionary caveat pertains only to thetest methods portion, Section 9, of this specification: Thisstandard does not purport to address the safety problems, ifany, ass
6、ociated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2C5
7、82 Specification for Contact-Molded Reinforced Thermo-setting Plastic (RTP) Laminates for Corrosion-ResistantEquipmentD883 Terminology Relating to PlasticsD1599 Test Method for Resistance to Short-Time HydraulicPressure of Plastic Pipe, Tubing, and FittingsD1600 Terminology forAbbreviated Terms Rela
8、ting to Plas-ticsD2996 Specification for Filament-Wound “Fiberglass”(Glass-Fiber-Reinforced Thermosetting-Resin) PipeD2997 Specification for Centrifugally Cast “Fiberglass”(Glass-Fiber-Reinforced Thermosetting-Resin) PipeD3262 Specification for “Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resi
9、n) Sewer PipeD3299 Specification for Filament-Wound Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant TanksD3517 Specification for “Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resin) Pressure PipeD3754 Specification for “Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resin) Sewer a
10、nd IndustrialPressure PipeD4097 Specification for Contact-Molded Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant Tanks2.2 ASME Standards:3B 16.1 Cast Iron Pipe Flanges and Flanged FittingsB 16.5 Pipe Flanges and Flanged FittingsB 18.21.1 Type “A” Narrow Washers3. Terminology3.1 Definition
11、s:3.1.1 Definitions are in accordance with Terminology D883.Abbreviations are in accordance with Terminology D1600,unless otherwise indicated. The abbreviation for reinforced-thermosetting-resin pipe is RTRP.3.2 Definitions of Terms Specific to This Standard:3.2.1 contact molding (CM)a method of fab
12、ricationwherein the glass fiber reinforcement is applied to the mold inthe form of all chopped-strand mat, or chopped-strand mat andwoven roving, in alternate plies by hand with the resin matrixapplied by brush or roller and the laminate consolidated by aroller.1This specification is under the juris
13、diction of ASTM Committee D20 onPlastics and is the direct responsibility of Subcommittee D20.23 on ReinforcedPlastic Piping Systems and Chemical Equipment.Current edition approved May 1, 2015. Published June 2015. Originallyapproved in 1993. Last previous edition approve in 2010 as D5421 05(2010).D
14、OI: 10.1520/D5421-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mech
15、anical Engineers (ASME), ASMEInternational Headquarters, Two Park Ave., New York, NY 10016-5990, http:/www.asme.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.2
16、 fiberglass pipea tubular product containing glass-fiber reinforcements embedded in or surrounded by curedthermosetting resin; the composite structure may containaggregate, granular or platelet fillers, thixotropic agents, pig-ments or dyes; thermoplastic or thermosetting liners or coat-ings may be
17、included.4. Classification4.1 GeneralThis specification covers reinforced-thermosetting-resin flanges defined by type (method ofmanufacture), grade (generic type of resin), class (pressure endthrust capability), and pressure rating. Flanges complying withthis specification are also given numerical c
18、lassifications relat-ing to rupture pressure and sealing test pressure.4.1.1 Types:4.1.1.1 Type AIntegral flange, contact molded with thestub integral with the flange.4.1.1.2 Type BFlange on pipe, contact molded onto anexisting pipe or fitting.4.1.2 Grades:4.1.2.1 Grade 1Epoxy resin.4.1.2.2 Grade 2P
19、olyester resin.4.1.2.3 Grade 3Phenolic resin.4.1.2.4 Grade 4Vinylester resin.4.1.2.5 Grade 5Furan resin.4.1.3 Classes:4.1.3.1 Class IHoop and axial-pressure.4.1.3.2 Class IIHoop pressure only.NOTE 2All combinations of type, liner, grade, and class may not becommercially available. Additional type, l
20、iner, grade, and class may beadded as they become commercially available. The purchaser shouldsolely determine or consult with the manufacturer for the proper class,type, liner, and grade to be used under the installation and operatingconditions that will exist for the project in which the flange is
21、 to be used.4.1.4 Pressure RatingPressure rating shall be categorizedby single-letter designation. Pressure designations are shown inTable 1.4.1.5 Short-term rupture pressure and sealing-test pressurelimits shall be categorized by single arabic number designa-tions as indicated by the cell classific
22、ation system of Table 2.4.2 Designation CodeThe flange-designation code shallconsist of the abbreviation for contact molded (CM) followedby the type as a capital letter, grade as anArabic numeral, classas a Roman numeral, and the pressure-rating category as acapital letter and two Arabic numbers ide
23、ntifying the cell-classification designations of the short-term rupture pressureand sealing-test pressure, respectively. Thus, a completeflange-designation code shall consist of three letters, oneArabic numeral, one Roman numeral, one letter and twonumerals.4.2.1 ExampleContact molded fiberglass is
24、CM-AlID-46.This designation described a stub flange, made using glass-fiber-reinforced epoxy resin for full-axial pressure thrust. Theflange has a 100-psi (0.69-MPa) pressure rating, a short-termrupture pressure of 400-psi (2.76-MPa), and a sealing-testpressure of 225-psi (1. 55-MPa).4.3 Attachment
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD54212015STANDARDSPECIFICATIONFORCONTACTMOLDEDFIBERGLASSGLASSFIBERREINFORCEDTHERMOSETTINGRESINFLANGESPDF

链接地址:http://www.mydoc123.com/p-432422.html