ANSI ASTM D4803-2010 Standard Test Method for Predicting Heat Buildup in PVC Building Products《预测PVC建筑产品中热积累效应的试验方法》.pdf
《ANSI ASTM D4803-2010 Standard Test Method for Predicting Heat Buildup in PVC Building Products《预测PVC建筑产品中热积累效应的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D4803-2010 Standard Test Method for Predicting Heat Buildup in PVC Building Products《预测PVC建筑产品中热积累效应的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4803 10 An American National StandardStandard Test Method forPredicting Heat Buildup in PVC Building Products1This standard is issued under the fixed designation D4803; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers prediction of the heat buildup inrigid and flexible PVC building products above a
3、mbient airtemperature, relative to black, which occurs due to absorptionof the suns energy.NOTE 1This test method is expected to be applicable to all types ofcolored plastics. The responsible subcommittee intends to broaden thescope beyond PVC when data on other materials is submitted for review.NOT
4、E 2There are no ISO standards covering the primary subjectmatter of this test method.1.2 Rigid PVC exterior profile extrusions for assembledwindows and doors are covered in Specification D4726.1.3 Rigid PVC exterior profiles for fencing are covered inSpecification F964.1.4 Rigid PVC siding profiles
5、are covered in SpecificationD3679.1.5 Rigid PVC soffit profiles are covered in SpecificationD4477.1.6 Rigid PVC and Rigid CPVC plastic building productscompounds are covered in Specification D4216.1.7 The text of this test method references notes andfootnotes which provide explanatory material. Thes
6、e notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of this test method.1.8 The values stated in inch-pound units are to be regardedas the standard.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use
7、. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific safetyhazard statements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Re
8、lating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD4703 Practice for Compression Molding ThermoplasticMaterials into Test Specimens, Plaques, or SheetsD3679 Specification for Rigid Poly(Vinyl Chloride) (PVC)SidingD4216 Specification for Rigid Poly(Vinyl Chloride) (PVC)and
9、 Related PVC and Chlorinated Poly(Vinyl Chloride)(CPVC) Building Products CompoundsD4477 Specification for Rigid (Unplasticized) Poly(VinylChloride) (PVC) SoffitD4726 Specification for Rigid Poly(Vinyl Chloride) (PVC)Exterior-Profile Extrusions Used for Assembled Windowsand DoorsE631 Terminology of
10、Building ConstructionsF964 Specification for Rigid Poly (Vinyl Chloride) (PVC)Exterior Profiles Used for Fencing and Railing3. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nologies D883 or E631 and abbreviations with TerminologyD1600 unless otherwise indicated.3.2 Definitions o
11、f Terms Specific to This Standard:3.2.1 heat buildupthe increase in temperature above thatof ambient air due to the amount of energy absorbed by aspecimen from the sun.3.2.2 temperature risethe increase in temperature abovethat of ambient (laboratory) air due to absorption of energyfrom a heating la
12、mp (source).4. Summary of Test Method4.1 The PVC product (extruded product, injection moldedpart, or compression molded) is cut apart to obtain a flat testspecimen at least 3 by 3 by 0.060 6 0.020 in. (76 by 76 by 1.56 0.5 mm).1This test method is under the jurisdiction of ASTM Committee D20 on Plas
13、ticsand is the direct responsibility of Subcommittee D20.24 on Plastic BuildingProducts.Current edition approved Nov. 1, 2010. Published January 2011. Originallyapproved in 1989. Last previous edition approved in 2002 as D4803 - 97 (2002)1.DOI: 10.1520/D4803-10.2For referenced ASTM standards, visit
14、the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100
15、Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 The test specimen is heated under the infrared reflectiveheat lamp to determine the temperature rise above ambient(laboratory) temperature relative to a black control sample.4.3 The temperature rise data, obtained in
16、 the laboratory fora given test specimen, is then used to predict the heat buildup,which may occur outdoors due to the sun.5. Significance and Use5.1 Heat buildup in PVC exterior building products due toabsorption of the energy from the sun may lead to distortionproblems. Heat buildup is affected by
17、 the color, emittance,absorptance, and reflectance of a product. Generally, the darkerthe color of the product, the more energy is absorbed and thegreater is the heat buildup. However, even with the sameapparent color, the heat buildup may vary due to the specificpigment system involved. The greates
18、t heat buildup generallyoccurs in the color black containing carbon black pigment. Theblack control sample used in this test method contains 2.5 partsof furnace black per 100 parts of PVC suspension resin. Themaximum temperature rise above ambient temperature for thisblack is 90F (50C) for a 45 or h
19、orizontal surface when thesun is perpendicular to the surface and 74F (41C) for avertical surface assuming that the measurements were done ona cloudless day with no wind and heavy insulation on the backof the specimen.3See Appendix X1.5.2 This test method allows the measurement of the tem-perature r
20、ise under a specific type heat lamp, relative to that ofa black reference surface, thus predicting the heat buildup dueto the suns energy.5.3 The test method allows prediction of heat buildup ofvarious colors or pigment systems, or both.5.4 This test method gives a relative heat buildup comparedto b
21、lack under certain defined severe conditions but does notpredict actual application temperatures of the product. Thesewill also depend on air temperature, incident angle of the sun,clouds, wind velocity, insulation, installation behind glass, etc.6. Apparatus6.1 Testing ApparatusThe apparatus shall
22、be constructedessentially as shown in Fig. 1 and shall consist of thefollowing:6.1.1 Wooden Box, opened from the top and the front andlined with 1-in. (25.4-mm) thick white rigid hydrous calciumsilicate heat insulation.6.1.2 White Infrared Heat Lamp, 250-W.46.1.3 Thermocouple, 40-gage Type J (iron-c
23、onstantan); orequivalent.6.1.4 Digital Read-Out Temperature Meter, Type J; orequivalent.NOTE 3The type of insulation may affect absolute temperature rise.However, the calculated values of predicted maximum heat buildup,relative to a black does not appear to be affected, based on a laboratorystudy co
24、mparing white rigid hydrous calcium silicate heat insulation withaluminum foil insulation having equivalent thermal resistance.NOTE 4The intensity of the heat lamp has an effect on absolutetemperature rise, however, it does not appear to influence the calculatedvalues of predicted maximum heat build
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD48032010STANDARDTESTMETHODFORPREDICTINGHEATBUILDUPINPVCBUILDINGPRODUCTS 预测 PVC 建筑 产品 积累 效应 试验

链接地址:http://www.mydoc123.com/p-432404.html