ANSI ASTM D4756-2015 Standard Practice for Installation of Rigid Poly(Vinyl Chloride) (PVC) Siding and Soffit.pdf
《ANSI ASTM D4756-2015 Standard Practice for Installation of Rigid Poly(Vinyl Chloride) (PVC) Siding and Soffit.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D4756-2015 Standard Practice for Installation of Rigid Poly(Vinyl Chloride) (PVC) Siding and Soffit.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4756 15 An American National StandardStandard Practice forInstallation of Rigid Poly(Vinyl Chloride) (PVC) Siding andSoffit1This standard is issued under the fixed designation D4756; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the basic requirements for and themethods of installation of rigid vin
3、yl siding, soffits, andaccessories on the exterior wall and soffit areas of buildings. Inall applications, refer also to the specific manufacturersinstallation instructions and the requirements of applicablebuilding codes.1.2 This practice covers aspects of installation relating toeffectiveness and
4、durability in service.1.3 The various application systems are located in thefollowing sections of this practice:Substrate, Surface Preparation Section 8Application of Horizontal Siding Section 9Application of Vertical Siding Section 10Application of Soffits and Fascia Section 11Special Details Secti
5、on 121.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any,
6、 associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standar
7、ds:2D883 Terminology Relating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD3679 Specification for Rigid Poly(Vinyl Chloride) (PVC)SidingD4477 Specification for Rigid (Unplasticized) Poly(VinylChloride) (PVC) SoffitE631 Terminology of Building ConstructionsE2112 Practice fo
8、r Installation of Exterior Windows, Doorsand Skylights3. Terminology3.1 GeneralDefinitions are in accordance with Terminolo-gies D883 and E631 and abbreviations with TerminologyD1600 unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 backerboarda flat material used o
9、n the face of thehouse, applied between the studs and the siding (or overexisting wall surface) to provide an even surface for theinstallation of the vinyl siding.3.2.2 buttlockthe bottom of a siding or soffit panel, oraccessory piece, opposite the nail hem, which locks onto thepreceding panel.3.2.3
10、 crimpsmall protrusions, typically approximately12in. (12.7 mm) long,18 in. (3.2 mm) wide, and projecting18 in.(3.2 mm) formed by a crimper (snaplock punch). (See Fig. 2.)3.2.4 crimpera special hand tool designed to form crimps(snaplock ears) intended to hold partial panels in place. (SeeFig. 2.)3.2
11、.5 face nailthe action of fastening directly on to the“face,” or exposed surface, of a panel (instead of using the nailslot).3.2.6 fasciathe trim covering the ends of roof rafters. (SeeFig. 1.)3.2.6.1 fascia boarda board attached to the ends of therafters between the roofing material and the soffit
12、overhang.3.2.6.2 fascia cap or coverthe covering around a fasciaboard.3.2.7 flashingspecial membrane pieces or manufacturedtrim pieces used to supplement siding panels in weatherprotection around joints, penetrations, and openings, such aswindows, doors, mechanical penetrations, and roof-wall1This p
13、ractice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.24 on Plastic Building Products.Current edition approved Feb. 1, 2015. Published February 2015. Originallyapproved in 1991. Last previous edition approved in 2013 as D4745 13. DOI:1
14、0.1520/D4756-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the
15、end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1intersections, designed and intended to move incidental waterto the building exterior.3.2.8 furring/furring stripa wooden or steel framingmaterial, usually a nominal
16、1 by 2 in. (25.4 by 50.8 mm) usedto even the surface in preparation for installation of siding. To“fur” a surface means to apply these strips.3.2.9 nailslot puncha special hand tool used to create slotsfor attachment of field-modified siding or accessories. (See Fig.3.)3.2.10 rake (roof)the inclined
17、, usually projecting edge ofa sloping roof.3.2.11 rake (wall)the board or molding placed along thesloping sides of a gable to cover the ends of the siding.3.2.12 snaplock earssee crimp and Fig. 2.3.2.13 snaplock punchsee crimper and Fig. 2.3.2.14 sofftthe underside surface (typically horizontal) ofr
18、oof overhangs.3.2.15 starter stripan accessory applied directly to thesurface of the building and used to secure the first course ofsiding to the home. Starter strips can either be a part manufac-tured for the specific purpose or created by cutting the nailinghem and adjacent lock from a siding pane
19、l.3.2.16 undersill trim (utility trim)an accessory strip usedto receive and hold the crimped edge of horizontal or verticalsiding that has had its normal lock removed.3.2.17 zip tool (unlocking tool)a special hand tool used toseparate interlocked siding panels. (See Fig. 2.)4. Delivery of Materials4
20、.1 All manufactured materials shall be delivered in theoriginal packages, containers, or bundles bearing the size ortype product, or both, brand name, and manufacturer (orsupplier) identification, manufacturers lot number, and theASTM specification to which it conforms.5. Protection of Materials5.1
21、Do not store in any location or in any manner where thetemperature of the siding, soffit or accessories is likely toexceed 130F (54C).FIG. 1 Terminology for Buildings, Siding and AccessoriesFIG. 2 Siding Installation ToolsD4756 1525.2 Store the cartons on a flat surface and support the entirelength
22、of the cartons.5.3 Store the cartons away from areas where falling objectsor other construction activity could impact the cartons. Keepthe cartons dry.5.4 Do not store the cartons in stacks more than 6 boxeshigh.6. Environmental Conditions6.1 Vinyl siding and accessories will expand when heatedand c
23、ontract when cooled. If siding is installed in hot weatherand the siding is very warm it will be partially “expanded.”Provide allowance for more future “contraction” than expan-sion.6.2 Leave14 in. (6.4 mm) clearance between the ends ofpanels and trim and any receiver such as J-channels and cornerpo
24、sts to allow for thermal expansion. If installing duringweather colder than 40F (4.4C), increase the minimumclearance to38 in. (9.5 mm) to allow for additional expansionduring warmer weather.7. Materials7.1 Horizontal Wall SidingSee Specification D3679.7.2 Vertical Wall SidingSee Specification D3679
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD47562015STANDARDPRACTICEFORINSTALLATIONOFRIGIDPOLYVINYLCHLORIDEPVCSIDINGANDSOFFITPDF

链接地址:http://www.mydoc123.com/p-432403.html