ANSI ASTM D4325-2013 Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes《非金属半导体和电绝缘胶带用试验方法》.pdf
《ANSI ASTM D4325-2013 Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes《非金属半导体和电绝缘胶带用试验方法》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D4325-2013 Standard Test Methods for Nonmetallic Semi-Conducting and Electrically Insulating Rubber Tapes《非金属半导体和电绝缘胶带用试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4325 13Standard Test Methods forNonmetallic Semi-Conducting and Electrically InsulatingRubber Tapes1This standard is issued under the fixed designation D4325; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 These test methods cover the
3、methods and proceduresfor testing electrically insulating and semi-nonmetallic con-ducting rubber tapes designed for splicing, terminating, andsheath repair of electrical wire and cable.1.2 The test methods appear in the following sections:SectionReferenced Documents 2Conditioning 5-6Dielectric Stre
4、ngth 3540Dimensions 1116Dissipation Factor 2226Elongation 1721Heat Exposure 4649Fusion 710Ozone Resistance 4145Permittivity 2226Sample Requirements 4Tensile Strength 1721Volume Resistivity 2734Ultraviolet and Weather Resistance 50541.3 The values stated in SI units are to be regarded asstandard. The
5、 values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.NOTE 1There is no IEC equivalent to these methods.1.4 Unless otherwise stated, measurements are made ontapes from which the removable separator has bee
6、n removed.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For
7、specificprecaution statements see 43.1.1.6 This is a fire-test response standard.2. Referenced Documents2.1 ASTM Standards:2D149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD150 Test Methods for AC Loss Ch
8、aracteristics and Permit-tivity (Dielectric Constant) of Solid Electrical InsulationD257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD374 Test Methods for Thickness of Solid Electrical Insu-lation (Withdrawn 2013)3D412 Test Methods for Vulcanized Rubber and Thermoplas-tic Ela
9、stomersTensionD470 Test Methods for Crosslinked Insulations and Jacketsfor Wire and CableD750 Practice for Rubber Deterioration Using ArtificialWeathering ApparatusD4388 Specification for Nonmetallic Semi-Conducting andElectrically Insulating Rubber TapesD4496 Test Method for D-C Resistance or Condu
10、ctance ofModerately Conductive MaterialsE591 Practice for Safety and Health Requirements Relatingto Occupational Exposure to Ozone43. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 fusion, nthat property of rubber tape which causesadjacent layers of tape to become bonded (amalga
11、mated) oradhered together when the tape is stretched and wound uponitself in layers.1These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.07 on Flexible and Rigid Insulating Materials
12、.Current edition approved Nov. 1, 2013. Published December 2013. Originallyapproved in 1997. Last previous edition approved in 2008 as D4325 08. DOI:10.1520/D4325-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual B
13、ook of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.*A Summary of Ch
14、anges section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1SAMPLING4. Sample and Specimen Requirements4.1 Unless otherwise required by the detailed productspecifications, take the rubber tapes at
15、random from eachshipment as follows:Number of Rollsin ShipmentNumber of SampleRolls50 to 200 2201 to 500 3501 to 1000 41001 to 5000 54.2 For shipments in excess of 5000 rolls, take one addi-tional roll for each additional 1000 rolls or fraction thereof.4.3 A shipment consists of material shipped or
16、intended forshipment to a customer and covered by one bill of lading.4.4 Test each sample roll in conformance to all requirementsof the specification.4.5 All test methods in this standard are intended to producea single value for a single roll. Any reference to averaging ofmeasurements refers to tes
17、t averaging on a single roll and notto the average of all sample rolls.4.6 Remove and discard at least 610 mm (24 in.) of the outerlayer of each roll before taking test specimens.4.7 Remove the test specimen from the roll at a slow,uniform rate without jerking.CONDITIONING5. Significance and Use5.1
18、The physical and electrical properties, including breakstrength, elongation, dielectric strength, dissipation factor,permittivity, fusion, etc., will vary with temperature andmoisture content. Control the temperature and moisture contentof the sample for these test methods to yield consistent andrep
19、roducible results.6. Procedure6.1 For referee purposes, subject the rolls to standardatmospheric conditions of 23 6 2 C (73.4 6 3.6 F) and 50 62 % relative humidity for a minimum period of 16 h beforespecimens are removed for test.6.2 Unless otherwise specified, condition all test specimensfor a per
20、iod of 1 h and conduct the tests in a standard laboratoryatmosphere at 23 6 2 C (73.4 6 3.6 F) and 50 6 2 % relativehumidity.FUSION7. Significance and Use7.1 Fusion is responsible for holding the tape in place toform a permanent compressive force about a conductor orinsulator in actual application.8
21、. Apparatus8.1 Winding FixtureThe winding fixture is designed tohold a metal rod at each end and is fitted with a crank or otherdevice to rotate the rod to allow the specimen to be woundthereon. Attach the fixture to a rigid support with the rod heldin a horizontal position.8.2 RodsAny suitable meta
22、l of 3-mm (0.125-in.) diameterand a minimum of 229 mm (9.0 in.) in length.8.3 Rule, graduated in inches, 762-mm (30-in.) minimumlength.8.4 Rule, graduated in 0.4 mm (164 in.).8.5 Razor Blades.8.6 Board, with 3-mm (0.125-in.) diameter holes spacedabout 50 mm (2 in.) apart on its surface to provide a
23、base forsupporting the rods in a near-vertical position.9. Procedure9.1 Prepare three specimens by cutting three strips of tape280 mm (11 in.) in length from the sample roll selected andconditioned in accordance with Sections 46. Prepare andwind specimens in a manner that prevents oils or otherconta
24、minants from getting on the bonding surface of the tape.9.2 Mount the rod horizontally in the winding fixture.9.3 Attach the strip of tape near one end of the rod bywinding the strip upon itself using 25 mm (1 in.) of the tape.Place the 762-mm (30-in.) rule next to the 254-mm (10-in.)tape strip. Str
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD43252013STANDARDTESTMETHODSFORNONMETALLICSEMICONDUCTINGANDELECTRICALLYINSULATINGRUBBERTAPES

链接地址:http://www.mydoc123.com/p-432384.html