ANSI ASTM D3755-1997 Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials under Direct-Voltage Stress《直流电压应力下电气绝缘材.pdf
《ANSI ASTM D3755-1997 Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials under Direct-Voltage Stress《直流电压应力下电气绝缘材.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D3755-1997 Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials under Direct-Voltage Stress《直流电压应力下电气绝缘材.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3755 14Standard Test Method forDielectric Breakdown Voltage and Dielectric Strength ofSolid Electrical Insulating Materials Under Direct-VoltageStress1This standard is issued under the fixed designation D3755; the number immediately following the designation indicates the year oforigin
2、al adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of dielectricbreakdown
3、voltage and dielectric strength of solid electricalinsulating materials under direct-voltage stress.1.2 Since some materials require special treatment, refer-ence shall also be made to ASTM specifications or to the testmethod directly applicable to the material to be tested. See TestMethod D149 for
4、the determination of dielectric strength ofelectrical insulating materials at commercial power frequen-cies.1.3 This test method is similar to IEC Publication 243-2.Allprocedures in this test method are included in IEC 243-2.Differences between this test method and IEC 243-2 are largelyeditorial.1.4
5、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precauti
6、onstatements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2D149 Test Method for Dielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD176 Test Methods for Solid Filling and Treating Com-pounds Used for Electric
7、al Insulation (Withdrawn 2013)3D877 Test Method for Dielectric Breakdown Voltage ofInsulating Liquids Using Disk ElectrodesD1711 Terminology Relating to Electrical InsulationD2436 Specification for Forced-Convection Laboratory Ov-ens for Electrical Insulation (Withdrawn 1994)3D3487 Specification for
8、 Mineral Insulating Oil Used inElectrical Apparatus2.2 ANSI Standard:4ANSI C68.1 Techniques for Dielectric Tests, IEEE StandardNo. 4.2.3 IEC Standard:IEC 243-2 Methods of test for electric strength of solidinsulating materialsPart 2: Additional requirements fortests using direct voltage43. Terminolo
9、gy3.1 Definitions:3.1.1 creepage distance, nshortest distance between twoconductive parts (typically metal), measured along the surfaceof the dielectric insulator.3.1.2 dielectric breakdown voltage, nRefer to Terminol-ogy D1711.3.1.3 dielectric strength, nRefer to Terminology D1711.3.1.4 flashover,
10、nRefer to Terminology D1711.4. Summary of Test Method4.1 The specimen, held in a properly designed electrodesystem, is electrically stressed by the application of an increas-ing direct voltage until internal breakdown occurs. The testvoltage is applied at a uniform rate of increase. The directvoltag
11、e is obtained from a high-voltage supply of adequatecurrent capacity and regulation, reasonably ripple-free, withfacilities for measuring and controlling the output voltage.5. Significance and Use5.1 This test method is intended for use as a control andacceptance test for direct-voltage applications
12、. It can also be1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.12 on Electrical Tests.Current edition approved May 15, 2014. Published June 2014. Originallyapproved in 1979. Last p
13、revious edition approved in 2004 as D3755 97 (2004),which was withdrawn in January 2013 and reinstated in June 2014. DOI:10.1520/D3755-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
14、information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.Copyright ASTM International, 10
15、0 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1used in the partial evaluation of material for specific end usesand as a means for detecting changes in material due to specificdeteriorating causes.5.2 Experience indicates that the breakdown value obtainedwith direct
16、 voltage usually will be approximately 2 to 4 timesthe rms value of the 60-Hz alternating-voltage breakdown.5.3 For a nonhomogeneous test specimen, the distributionof voltage stress within the specimen is determined by imped-ance (largely capacitive) with alternating voltage. With anincreasing direc
17、t voltage, the voltage distribution will still belargely capacitive, although this depends partly on the rate ofvoltage increase. After steady application of direct voltage thevoltage division across the test specimen is determined byresistance. The choice of direct or alternating voltage dependsupo
18、n the purpose for which the breakdown test is to be used,and to some extent, on the intended application of the material.5.4 A more complete discussion of the significance ofdielectric breakdown tests is given in Appendix X1 of thismethod and in Appendix X1 of Test Method D149. Thoseappendix section
19、s of Test Method D149 that refer to alternatingvoltage are not applicable to the direct-voltage method.6. Apparatus6.1 Basic Direct-Voltage Power Supplies, or dielectric testsets of various voltage ratings, which can operate with one ofthe two output terminals grounded, are commonly availablecommerc
20、ially. Such apparatus customarily includes the neces-sary voltage-control, voltage-measuring, and circuit-interrupting equipment. A provision for retaining the break-down voltage reading after breakdown is desirable.6.1.1 For a direct voltage derived from a rectified andfiltered power frequency sour
21、ce, ripple on the output voltageshall be less than 1 %. The criterion is met if the time constantof the circuit is at least 0.4 s. The time constant is product ofthe filter capacitance plus the specimen capacitance inmicrofarads, and the specimen insulation resistance (in mega-ohms) corresponding to
22、 the parallel combination of the volt-meter circuit resistance and the specimen resistance.6.2 Voltage Control, that will enable the test voltage to beincreased at a linear rate. Preference shall be given to avariable-speed motor-driven voltage control over a manualcontrol. The rate-of-rise of test
23、voltage shall not vary more than620 % from the specified rate at any point.6.3 Voltmeter, to measure the voltage directly applied to theelectrode system. The response of the voltmeter shall be suchthat its time lag shall not introduce an error greater than 1 % offull scale at any rate-of-rise used.
24、The overall accuracy of thevoltmeter and the voltage-measuring device used shall be suchthat the measurement error will not exceed 62 % of full scaleand be in accordance with ANSI C68.1.6.4 Electrodes:6.4.1 For those cases when the insulating material is in theform of flat sheet or tape, or is of th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD37551997STANDARDTESTMETHODFORDIELECTRICBREAKDOWNVOLTAGEANDDIELECTRICSTRENGTHOFSOLIDELECTRICALINSULATINGMATERIALSUNDERDIRECTVOLTAGESTRESS

链接地址:http://www.mydoc123.com/p-432363.html