《ANSI ASTM D3150-2011 Standard Specification for Crosslinked and Noncrosslinked Poly(Vinyl Chloride) Heat- Shrinkable Tubing for Electrical Insulation《电绝缘用交联和非交联聚乙烯热缩管型材料规范》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D3150-2011 Standard Specification for Crosslinked and Noncrosslinked Poly(Vinyl Chloride) Heat- Shrinkable Tubing for Electrical Insulation《电绝缘用交联和非交联聚乙烯热缩管型材料规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3150 11Standard Specification forCrosslinked and Noncrosslinked Poly(Vinyl Chloride) Heat-Shrinkable Tubing for Electrical Insulation1This standard is issued under the fixed designation D3150; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification applies to flexible, crosslinked andnoncrosslinked poly(vinyl
3、chloride) heat-shrinkable tubing forelectrical insulating purposes. It is supplied in an expandedform and will shrink to its extruded diameter when heated.NOTE 1This standard is similar but not identical to IEC 606843201.1.2 The values stated in inch-pound units are to be regardedas standard. The va
4、lues given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.2.1 In some cases (including the title), temperatures aredescribed in degrees Celsius only.2. Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating t
5、o Electrical InsulationD2671 Test Methods for Heat-Shrinkable Tubing for Elec-trical UseD3636 Practice for Sampling and Judging Quality of SolidElectrical Insulating MaterialsE176 Terminology of Fire Standards2.2 Military Standards:3MIL-STD-104 Limits for Electrical Insulation ColorMIL-H-5606 Hydrau
6、lic Fluid, Petroleum Base, Aircraft,Missile, and OrdnanceMIL-T-5624 Turbine Fuel, Aviation, Grades JP-4 and JP-5MIL-L-7808 Lubricating Oil, Aircraft, Turbine Engine, Syn-thetic BaseMIL-L-23699 Lubricating Oil, Aircraft, Turbine Engines,Synthetic BaseMIL-A-8243 Anti-Icing and De-Icing Defrosting Flui
7、d2.3 Federal Standards:SS-S-550 Sodium Chloride, Technical, for Water-SofteningUnits42.4 IEC Standards:606843201 Flexible insulating sleeving, Part 3, Sheet 201:Heat shrinkable sleeving, general purpose, flexible, cross-linked PVC, shrink ratio 2:153. Terminology3.1 Definitions:3.1.1 For definitions
8、 pertaining to electrical insulation, referto Terminology D1711.3.1.2 For definitions pertaining to fire standards, refer toTerminology E176.4. Classification4.1 Type IFlexible, noncrosslinked poly(vinyl chloride)tubing capable of being shrunk at 135C (275F) in 15 min.4.2 Type IIFlexible, crosslinke
9、d poly(vinyl chloride) tub-ing capable of being shrunk at 175C (347F) in 15 min.5. Ordering Information5.1 When tubing is ordered to this specification, the pur-chaser shall define the size, color, and type of the requiredtubing.6. Materials and Manufacture6.1 The polymers used in the manufacture of
10、 heat-shrinkable tubing shall be modified poly(vinyl chloride) andthe finished compound shall be free of all foreign matter otherthan intended formulation additives as appropriate.6.2 The tubing shall be extruded, crosslinked (Type II only),and then expanded to the required dimensions.7. Chemical an
11、d Physical Property Requirements7.1 The material shall conform to the chemical and physicalproperty requirements specified in Table 1.1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D
12、09.07 on Flexible and Rigid Insulating Materials.Current edition approved Aug. 1, 2011. Published August 2011. Originallyapproved in 1973. Last previous edition approved in 2006 as D3150 00 (2006).DOI: 10.1520/D3150-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact A
13、STM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.4Available
14、from Superintendent of Documents, U.S. Government PrintingOffice, Washington, DC 20402.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM Intern
15、ational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, G
16、uides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.17.2 Every lot of material shall be tested for dimensionalrequirements, restricted shrinkage, tensile strength, elongation,longitudinal change, and dielectric breakdown. Other require-ments s
17、hall be tested at a frequency agreed upon between thesupplier and the purchaser.8. Dimensional Requirements8.1 Type I material shall conform to the applicable require-ments listed in Table 2 or Table 3.8.2 Type II material shall conform to the requirements listedin Table 3.8.3 Tubing with non-standa
18、rd dimensions shall be suppliedonly when agreed upon between purchaser and seller. Tubingwith non-standard dimensions shall be considered to complywith this specification if the requirements of Table 1 and Table2 are satisfied and the minimum recovered wall thicknessequals or exceeds that of the ide
19、ntical or next largest assupplied size. The wall for sizes greater than the largestspecified size shall be at least as thick as that of the largestspecified size.TABLE 1 Chemical and Physical Property RequirementsPropertyRequirementsType I Type IIRestricted shrinkage, Procedure A:Type I30 min, 135 2
20、C (275 4F) no cracksType II30 min, 175 2C (374 4F) no cracks2000-V proof voltage no failures no failuresLongitudinal change, max, % 0, 25 + 1, 10Dielectric strength, V/mil (kV/mm) 400 (15.75) 400 (15.75)Color MIL-STD-104 MIL-STD-104Color stability, 24 h at 130 2C (266 4F) MIL-STD-104 MIL-STD-104Wate
21、r absorption, 24 h at 25 2C (77 4F), max, % 1.0 1.0Specific gravity, max 1.40 1.40Volume resistivity, min, ohmcm 10111011Flammability, max, s, Procedure A 15 15Heat shock:Type I4 h at 180 2C (236 4F) no dripping, flowing, or crackingType II4 h at 200 2C (392 4F) no dripping, flowing, or crackingLow-
22、temperature flexibility, Procedure B, all sizes1hat 10C (14F) on as-received specimensno cracking no crackingTensile strength, min, psi (MPa) 2000 (13.8) 2000 (13.8)Elongation, min, % 200 200Heat resistance, 168 h at 136 2C (277 4F), followedby tests for:Elongation, min, % 150 130Elongation, % of or
23、iginal, min 65 65Fluid resistance, 24 h at 25 2C (77 4F):Hydraulic Fluid, MIL-H-5606JP-4 Fuel, MIL-T-5624Lubricating Oil, MIL-L-7808Lubricating Oil, MIL-L-23699De-icing Fluid, MIL-A-82435 % NaCl, SS-S-550Followed by tests for:Dielectric strength, V/mil (kV/mm) 280 (11.0) 280 (11.0)Tensile strength,
24、min, psi (MPa) 1800 (12.4) 2000 (13.8)Copper corrosion, Procedure B:168 h at 136C (277F) no blackening or pitting of copper no blackening or pitting of copperCopper dust humidity test, Procedure C no corrosion or discoloration of copper dust no corrosion or discoloration of copper dustShelf lifeThe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD31502011STANDARDSPECIFICATIONFORCROSSLINKEDANDNONCROSSLINKEDPOLYVINYLCHLORIDEHEATSHRINKABLETUBINGFORELECTRICALINSULATION

链接地址:http://www.mydoc123.com/p-432328.html