《ANSI ASTM D1785-2015 Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Schedules 40 80 and 120《聚氯乙烯(氯乙烯)(PVC)塑料管规格 表40、80、120》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM D1785-2015 Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Schedules 40 80 and 120《聚氯乙烯(氯乙烯)(PVC)塑料管规格 表40、80、120》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1785 15 An American National StandardStandard Specification forPoly(Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80,and 1201This standard is issued under the fixed designation D1785; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1
3、This specification covers poly(vinyl chloride) (PVC)pipe made in Schedule 40, 80, and 120 sizes and pressure-ratedfor water (see Appendix X1). Included are criteria for classi-fying PVC plastic pipe materials and PVC plastic pipe, asystem of nomenclature for PVC plastic pipe, and requirementsand tes
4、t methods for materials, workmanship, dimensions,sustained pressure, burst pressure, flattening, and extrusionquality. Methods of marking are also given.1.2 The products covered by this specification are intendedfor use with the distribution of pressurized liquids only, whichare chemically compatibl
5、e with the piping materials. Due toinherent hazards associated with testing components and sys-tems with compressed air or other compressed gases somemanufacturers do not allow pneumatic testing of their products.Consult with specific product/component manufacturers fortheir specific testing procedu
6、res prior to pneumatic testing.NOTE 1Pressurized (compressed) air or other compressed gasescontain large amounts of stored energy which present serious safteyhazards should a system fail for any reason.NOTE 2This standard specifies dimensional, performance and testrequirements for plumbing and fluid
7、 handling applications only. It doesnot include provisions for the use of these products for venting ofcombustion gases. UL 1738 is a standard that does include specific testingand marking requirements for flue gas venting products, including PVC.1.3 The text of this specification references notes,
8、footnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specification.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathe
9、maticalconversions to SI units that are provided for information onlyand are not considered standard.1.5 The following safety hazards caveat pertains only to thetest methods portion, Section 8, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associa
10、ted with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use. A specific precautionary statement is givenin Note 9.NOTE 3CPVC plastic pipes, Schedules 40 and 80, whic
11、h wereformerly included in this specification, are now covered by SpecificationF441/F441M.NOTE 4The sustained and burst pressure test requirements, and thepressure ratings in the Appendix X1, are calculated from stress valuesobtained from tests made on pipe 4 in. (100 mm) and smaller. However,tests
12、conducted on pipe as large as 24-in. (600-mm) diameter have shownthese stress values to be valid for larger diameter PVC pipe.NOTE 5PVC pipe made to this specification is often belled for use asline pipe. For details of the solvent cement bell, see Specification D2672and for details of belled elasto
13、meric joints, see Specifications D3139 andD3212.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD1598 Test Method for Time-to-Failure of Plastic PipeUnder Constant Internal PressureD1599 Test Method for Resistance to Short-Time HydraulicPressure of Plast
14、ic Pipe, Tubing, and FittingsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Me
15、thod for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone ImmersionD2672 Specification for Joints for IPS PVC Pipe UsingSolvent Cement1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibili
16、ty of Subcommittee F17.25 on VinylBased Pipe.Current edition approved Aug. 1, 2015. Published August 2015. Originallyapproved in 1960. Last previous edition approved in 2012 as D1785 12. DOI:10.1520/D1785-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
17、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
18、19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Te
19、chnical Barriers to Trade (TBT) Committee.1D2837 Test Method for Obtaining Hydrostatic Design Basisfor Thermoplastic Pipe Materials or Pressure Design Basisfor Thermoplastic Pipe ProductsD3139 Specification for Joints for Plastic Pressure PipesUsing Flexible Elastomeric SealsD3212 Specification for
20、Joints for Drain and Sewer PlasticPipes Using Flexible Elastomeric SealsF412 Terminology Relating to Plastic Piping SystemsF441/F441M Specification for Chlorinated Poly(Vinyl Chlo-ride) (CPVC) Plastic Pipe, Schedules 40 and 802.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencie
21、s)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage32.4 NSF/ANSI Standards:4Standard No. 14 for Plastic Piping System Components andRelated MaterialsStandard No. 61 for Drinking Water System ComponentsHealth Effects2.5 UL Standard:5UL 1738 Standard for Venting Systems for Gas-Burni
22、ngAppliances, Categories II, III, and IV3. Terminology3.1 Definitions:Definitions are in accordance with Termi-nology F412 and abbreviations are in accordance with Termi-nology D1600, unless otherwise specified. The abbreviation forpoly(vinyl chloride) plastic is PVC.3.2 Definitions of Terms Specifi
23、c to This Standard:3.2.1 hydrostatic design stressthe estimated maximumtensile stress the material is capable of withstanding continu-ously with a high degree of certainty that failure of the pipewill not occur. This stress is circumferential when internalhydrostatic water pressure is applied.3.2.2
24、pressure rating (PR)the estimated maximum waterpressure the pipe is capable of withstanding continuously witha high degree of certainty that failure of the pipe will not occur.3.2.3 relation between dimensions, design stress, and pres-sure ratingthe following expression, commonly known asthe ISO equ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD17852015STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEPVCPLASTICPIPESCHEDULES4080AND120 聚氯乙烯 氯乙烯

链接地址:http://www.mydoc123.com/p-432255.html