ANSI ASME MFC-26-2011 Measurement of Gas Flow by Bellmouth Inlet Flowmeters《喇叭进水口流量计对气流量的计量》.pdf
《ANSI ASME MFC-26-2011 Measurement of Gas Flow by Bellmouth Inlet Flowmeters《喇叭进水口流量计对气流量的计量》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASME MFC-26-2011 Measurement of Gas Flow by Bellmouth Inlet Flowmeters《喇叭进水口流量计对气流量的计量》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、AN AMERICAN NATIONAL STANDARDASME MFC-262011Measurement of Gas Flow by Bellmouth Inlet FlowmetersASME MFC-262011Measurement of Gas Flow by Bellmouth Inlet FlowmetersAN AMERICAN NATIONAL STANDARDThree Park Avenue New York, NY 10016 USADate of Issuance: August 10, 2011This Standard will be revised whe
2、n the Society approves the issuance of a new edition. There will be no addenda issued to this edition.ASME issues written replies to inquiries concerning interpretations of technical aspects of this Standard. Periodically certain actions of the ASME MFC Committee may be published as Cases. Cases and
3、 interpretations are published on the ASME Web site under the Committee Pages at http:/cstools.asme.org as they are issued.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for Amer
4、ican National Standards. The Standards Committee that approved the code or standard was balanced to assure that individuals from competent and concerned interests have had an opportunity to participate. The proposed code or standard was made available for public review and comment that providesan op
5、portunity for additional public input from industry, academia, regulatory agencies, and the public-at-large.ASME does not approve, rate, or endorse any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in co
6、nnection with any items mentioned in this document, and does not undertake to insure anyone utilizing a standard against liability for infringement of any applicable letters patent, nor assumes any such liability. Users of a code or standard are expressly advised that determination of the validity o
7、f any such patent rights, and the risk of infringement of such rights, is entirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted as government or industry endorsement of this code or standard.ASME accepts res
8、ponsibility for only those interpretations of this document issued in accordance with the established ASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,wit
9、hout the prior written permission of the publisher.The American Society of Mechanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2011 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.iiiCONTENTSForeword ivCommittee Roster vCorrespondence With the MF
10、C Committee vi1 General . 12 References . 13 Definitions and Symbols 24 Principle of Measurement and Method of Computation . 35 Flow Conditioning . 116 General Requirements 127 Discharge Coefficient Development 148 Uncertainties in the Measurement of Flow Rate 16Figures4.1-1 Bellmouth Inlet Flow Noz
11、zle General Description (Side View) 64.1-2 Bellmouth Inlet Flow Nozzle General Description (Front View) 64.3-1 Clean Inlet Method 84.3-2 Combo Probe: Ptand PsMethod . 94.3-3 Combo Probe: Ptand TtMethod . 105.2-1 Typical Boundary Layer Growth, Flat Plate Model 127.3-1 Inlet Instrumentation (Technique
12、 From Para. 4.3.1) . 15Table3.3-1 Symbols . 4Nonmandatory AppendicesA Sample Calculation Equation Set 19B Example of Empirically Derived Sensitivity . 20C Derivation of Sample Equation . 21D References for Additional Reading . 25ivFOREWORDThe bellmouth is a common device for flow conditioning and fl
13、ow measurement in the aerospace industry. Specifically, the bellmouth is attached to the front end of a turbofan gas turbine engine. Turboshaft engine applications also use the bellmouth but typically for flow conditioning and less frequently for flow measurement. The automotive industry also uses t
14、he bellmouth in some test applications. This Standard was prepared by Subcommittee 26, Bellmouth Inlet Flowmeters, of the ASME Standards Committee on Measurement of Fluids in Closed Conduits (MFC).This is the initial release of this Standard.This Standard provides information in both SI (metric) uni
15、ts and U.S. Customary units. Suggestions for improvement of this Standard are welcome. They should be sent to The American Society of Mechanical Engineers; Secretary, MFC Standards Committee; Three Park Avenue; New York, NY 10016-5990. This Standard was approved by the American National Standards In
16、stitute on March 30, 2011.vASME MFC COMMITTEEMEASUREMENT OF FLUID FLOW IN CLOSED CONDUITS(The following is the roster of the Committee at the time of approval of this Standard.)STANDARDS COMMITTEE OFFICERSR. J. DeBoom, ChairZ. D. Husain, Vice ChairD. C. Wyatt, Vice ChairC. J. Gomez, SecretarySTANDAR
17、DS COMMITTEE PERSONNELC. J. Blechinger, Honorary Member, ConsultantR. M. Bough, Rolls-Royce Corp.M. S. Carter, Flow Systems, Inc.G. P. Corpron, Honorary Member, ConsultantR. J. DeBoom, ConsultantD. Faber, Contributing Member, Badger Meter, Inc.C. J. Gomez, The American Society of Mechanical Engineer
18、sF. D. Goodson, Emerson Process Management, Daniel DivisionZ. D. Husain, Chevron Corp.C. G. Langford, Honorary Member, ConsultantT. O. Maginnis, ConsultantW. M. Mattar, Invensys/Foxboro Co.G. E. Mattingly, The Catholic University of AmericaR. W. Miller, Honorary Member, R. W. Miller however, they sh
19、ould not contain proprietary names or information.Requests that are not in this format will be rewritten in this format by the Committee prior to being answered, which may inadvertently change the intent of the original request.ASME procedures provide for reconsideration of any interpretation when o
20、r if additional information that might affect an interpretation is available. Further, persons aggrieved by an interpretation may appeal to the cognizant ASME Committee or Subcommittee. ASME does not “approve,” “certify,” “rate,” or “endorse” any item, construc-tion, proprietary device, or activity.
21、Attending Committee Meetings. The MFC Committee regularly holds meetings, which are open to the public. Persons wishing to attend any meeting should contact the Secretary of the MFC Standards Committee.ASME MFC-262011MEASUREMENT OF GAS FLOW BY BELLMOUTH INLET FLOWMETERS11 GENERAL1.1 ScopeThis Standa
22、rd applies only to the steady flow of single-phase gases and gas mixtures and applies only to bellmouth inlet flowmeters in which the flow remains subsonic throughout the measuring section and the flow is steady or varies only slowly with time. It also addresses procedures by which calibration of th
23、e device can be made to allow for application with consistent conclusions and within known limits of uncertainty. Bellmouth inlet flowmeters should be used only within the limits for which a given unit is tested, or if additional uncertainty can be tolerated, over a range within which extrapolation
24、is reliable.This Standard outlines the general geometry and method of use of bellmouth inlet flowmeters to deter-mine the mass or volumetric flow rate of the gas or gas mixture flowing through the device. It also gives nec-essary information for calculating the flow rate and its associated uncertain
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASMEMFC262011MEASUREMENTOFGASFLOWBYBELLMOUTHINLETFLOWMETERS 喇叭 进水 流量计 流量 计量 PDF

链接地址:http://www.mydoc123.com/p-432000.html