ANSI ASME MFC-14M-2003 Measurement of Fluid Flow Using Small Bore Precision Orifice Meters《小孔精密孔板仪测量流体的流量》.pdf
《ANSI ASME MFC-14M-2003 Measurement of Fluid Flow Using Small Bore Precision Orifice Meters《小孔精密孔板仪测量流体的流量》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASME MFC-14M-2003 Measurement of Fluid Flow Using Small Bore Precision Orifice Meters《小孔精密孔板仪测量流体的流量》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、AN AMERICAN NATIONAL STANDARDASME MFC-14M2003(Revision of ASME MFC-14M2001)MEASUREMENT 0FFLUID FLOW USINGSMALL BOREPRECISIONORIFICE METERSIntentionally left blank AN AMERICAN NATIONAL STANDARDMEASUREMENT OFFLUID FLOW USINGSMALL BOREPRECISIONORIFICE METERSASME MFC-14M2003(Revision of ASME MFC-14M2001
2、)Date of Issuance: April 17, 2003This Standard will be revised when the Society approves the issuance of a new edition. There willbe no addenda issued to this edition.ASME will issue written replies to inquiries concerning interpretations of technical aspects of thisStandard. Interpretations are pub
3、lished on the ASME Web site under the Committee Pages at http:/www.asme.org/codes/ as they are issued.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for American NationalStandard
4、s. The Standards Committee that approved the code or standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate. The proposed code or standard was madeavailable for public review and comment that provides an opportunity for additiona
5、l public input from industry, academia,regulatory agencies, and the public-at-large.ASME does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in connection with anyi
6、tems mentioned in this document, and does not undertake to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent, nor assume any such liability. Users of a code or standard are expresslyadvised that determination of the validity of any such patent righ
7、ts, and the risk of infringement of such rights, isentirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted asgovernment or industry endorsement of this code or standard.ASME accepts responsibility for only tho
8、se interpretations of this document issued in accordance with the establishedASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior written pe
9、rmission of the publisher.The American Society of Mechanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2003 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll Rights ReservedPrinted in U.S.A.CONTENTSForeword ivCommittee Roster . vCorrespondence With the MFC Committee . vi1 Scope an
10、d Field of Application 12 References and Related Documents 13 Symbols and Definitions 14 Principle of Measurement and Method of Computation 75 General Measurement Requirements . 96 Installation Requirements . 97 Discharge Coefficient and Empirical Equations 148 Uncertainties . 169 Pressure Loss, H90
11、04H9275 (h) 17Figures1 Standard Orifice Plate . 112 Corner Tap Geometry 133 Location for Orifice Flange Pressure Taps . 144 Honed Small Bore Orifice Flow Section With Corner Taps . 15Tables1 Symbols . 22 Minimum Recommended Upstream Straight Length Required to Achieve anUncertainty of 0.75% . 10iiiF
12、OREWORDBefore the publication of this Standard, there was no standard covering the measurementsof fluid flows using small bore precision orifice meters (nominal line sizes of14in. through 112in.) using differential pressure devices. Most people have used ASME fluid meters for guidanceor obtained inf
13、ormation from the manufacturers of proprietary devices.This Standard has been prepared by the ASME Committee on Measurement of Fluid Flows inClosed Conduit (MFC).Suggestions for improvement of this Standard should be sent to: Secretary, MFC, The AmericanSociety of Mechanical Engineers, Three Park Av
14、enue, New York, NY 10016.This Standard was approved as an American National Standard on February 26, 2003.ivASME MFC COMMITTEEMeasurement of Fluid Flow in Closed Conduits(The following is the Roster of the Committee at the time of approval of this Standard.)OFFICERSZ. D. Husain, ChairR. J. DeBoom, V
15、ice ChairR. L. Crane, SecretaryCOMMITTEE PERSONNELC. J. Blechinger, ConsultantR. W. Caron, Visteon Corp.G. P. Corpron, ConsultantR. L. Crane, The American Society of Mechanical EngineersR. J. DeBoom, Daniel Measurement and ControlP. G. Espina, Controlotron Corp.D. Faber, Badger Meter, Inc.R. H. Frit
16、z, Saudi AramcoF. D. Goodson, Daniel Measurement and ControlZ. D. Husain, Chevron TexacoE. H. Jones, Jr., Chevron Petroleum TechnologiesT. M. Kegel, Colorado Engineering Experiment Station, Inc.C. G. Langford, Cullen G. Langford, Inc.W. M. Mattar, Invensys / Foxboro Co.G. E. Mattingly, National Inst
17、itute of Standards and TechnologyD. R. Mesnard, Direct Measurement Corp.R. W. Miller, R. W. Miller and Associates, Inc.A. M. Quraishi, American Gas AssociationB. K. Rao, ConsultantW. F. Seidl, Colorado Engineering Experiment Station, Inc.D. W. Spitzer, Cooperhill and Pointer, Inc.D. H. Strobel, Cons
18、ultantJ. H. Vignos, ConsultantD. E. Wiklund, Rosemount, Inc.D. C. Wyatt, Wyatt Engineering and DesignSUBCOMMITTEE 23 SMALL BORE ORIFICE METERSZ. D. Husain, Chair, Chevron TexacoR. L. Crane, Secretary, The American Society of Mechanical EngineersG. P. Corpron, ConsultantG. E. Mattingly, National Inst
19、itute of Standards and TechnologyR. J. W. Peters, McCrometerD. E. Wiklund, Rosemount, Inc.D. C. Wyatt, Wyatt Engineering and DesignvCORRESPONDENCE WITH THE MFC COMMITTEEGeneral. ASME Standards are developed and maintained with the intent to representthe consensus of concerned interests. As such, use
20、rs of this Standard may interact with theCommittee by requesting interpretations, proposing revisions, and attending committeemeetings. Correspondence should be addressed to:Secretary, MFC Standards CommitteeThe American Society of Mechanical EngineersThree Park AvenueNew York, NY 10016-5990Proposin
21、g Revisions. Revisions are made periodically to the Standard to incorporatechanges that appear necessary or desirable, as demonstrated by the experience gained fromthe application of the Standard. Approved revisions will be published periodically.The Committee welcomes proposals for revisions to thi
22、s Standard. Such proposals shouldbe as specific as possible, citing the paragraph number(s), the proposed wording, and adetailed description of the reasons for the proposal, including any pertinent documentation.Interpretations. Upon request, the MFC Committee will render an interpretation ofany req
23、uirement of the Standard. Interpretations can only be rendered in response to awritten request sent to the Secretary of the MFC Standards Committee.The request for interpretation should be clear and unambiguous. It is further recom-mended that the inquirer submit his request in the following format:
24、Subject: Cite the applicable paragraph number(s) and the topic of the inquiry.Edition: Cite the applicable edition of the Standard for which the interpretationis being requested.Question: Phrase the question as a request for an interpretation of a specificrequirement suitable for genral understandin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASMEMFC14M2003MEASUREMENTOFFLUIDFLOWUSINGSMALLBOREPRECISIONORIFICEMETERS 小孔 精密 孔板仪 测量 流体 流量 PDF

链接地址:http://www.mydoc123.com/p-431993.html