ANSI ASHRAE 180-2012 Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems.pdf
《ANSI ASHRAE 180-2012 Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems.pdf》由会员分享,可在线阅读,更多相关《ANSI ASHRAE 180-2012 Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Practice forInspection andMaintenance ofCommercial BuildingHVAC SystemsANSI/ASHRAE/ACCA Standard 180-2012(Supersedes ANSI/ASHRAE/ACCA Standard 180-2008)See Informative Appendix D for approval dates by the ASHRAE Standards Committee, the ASHRAE Board of Directors, Air Con-ditioning Contracto
2、rs of America, and American National Standards Institute.ASHRAE Standards are scheduled to be updated on a five-year cycle; the date following the standard number is the year ofASHRAE Board of Directors approval. The latest edition of an ASHRAE Standard may be purchased on the ASHRAE Web site(www.as
3、hrae.org) or from ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mail:ordersashrae.org. Fax: 404-321-5478. Telephone: 404-636-8400 (worldwide) or toll free 1-800-527-4723 (for orders in US andCanada). For reprint permission, go to www.ashrae.org/permissions. 2012 ASHRAE a
4、nd ACCA ISSN 1041-2336SPECIAL NOTEThis American National Standard (ANS) is a national voluntary consensus standard developed under the auspices of ASHRAE.Consensus is defined by the American National Standards Institute (ANSI), of which ASHRAE is a member and which has approved thisstandard as an AN
5、S, as “substantial agreement reached by directly and materially affected interest categories. This signifies the concurrenceof more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that aneffort be made toward their resolution
6、.” Compliance with this standard is voluntary until and unless a legal jurisdiction makes compliancemandatory through legislation.ASHRAE obtains consensus through participation of its national and international members, associated societies, and public review.ASHRAE Standards are prepared by a Proje
7、ct Committee appointed specifically for the purpose of writing the Standard. The ProjectCommittee Chair and Vice-Chair must be members of ASHRAE; while other committee members may or may not be ASHRAE members, allmust be technically qualified in the subject area of the Standard. Every effort is made
8、 to balance the concerned interests on all ProjectCommittees.The Manager of Standards of ASHRAE should be contacted for:a. interpretation of the contents of this Standard,b. participation in the next review of the Standard,c. offering constructive criticism for improving the Standard, ord. permissio
9、n to reprint portions of the Standard.DISCLAIMERASHRAE uses its best efforts to promulgate Standards and Guidelines for the benefit of the public in light of available information andaccepted industry practices. However, ASHRAE does not guarantee, certify, or assure the safety or performance of any
10、products, components,or systems tested, installed, or operated in accordance with ASHRAEs Standards or Guidelines or that any tests conducted under itsStandards or Guidelines will be nonhazardous or free from risk.ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDSASHRAE Standards and Guidelines are e
11、stablished to assist industry and the public by offering a uniform method of testing for ratingpurposes,bysuggestingsafepracticesindesigningandinstallingequipment,byprovidingproperdefinitionsofthisequipment,andbyprovidingother information that may serve to guide the industry.The creation of ASHRAE S
12、tandards and Guidelines is determined by the need for them,and conformance to them is completely voluntary.In referring to this Standard or Guideline and in marking of equipment and in advertising, no claim shall be made, either stated or implied,that the product has been approved by ASHRAE.ASHRAE S
13、TANDARDS COMMITTEE 20112012Carol E. Marriott, Chair Krishnan Gowri Janice C. PetersonKenneth W. Cooper, Vice-Chair Maureen Grasso Douglas T. ReindlDouglass S. Abramson Cecily M. Grzywacz Boggarm S. SettyKarim Amrane Richard L. Hall James R. TaubyCharles S. Barnaby Rita M. Harrold James K. VallortHoy
14、 R. Bohanon, Jr. Adam W. Hinge William F. WalterSteven F. Bruning Debra H. Kennoy Michael W. WoodfordDavid R. Conover Jay A. Kohler Craig P. WraySteven J. Emmerich Eckhard A. Groll, BOD ExOAllan B. Fraser Ross D. Montgomery, COStephanie C. Reiniche, Manager of StandardsASHRAE Standing Standard Proje
15、ct Committee 180CognizantTCs: Lead CognizantTC 7.3, Operation and Maintenance Management;Co-CognizantTC 2.4, Particulate Air Contaminants and Particulate Contamination Removal Equipment;and Co-CognizantTC 9.8, Large Buildings Air-Conditioning ApplicationsASHRAE Staff Liaison: Mark J. WeberSPLS Liais
16、on (20082011): Allan B. FraserSPLS Liaison (20112012): Rita M. HarroldCharles Eugene Dale-Derks, Chair Jennifer A. Isenbeck Marc NewmanRichard Alan Danks, Chair (20102011) S. Louis Kelter Stephen W. NicholasRobert G. Baker, Chair (20082010) Carl N. Lawson Thomas L. PaxsonMark M. Anderson Angela M. L
17、ewis Robert J. RothRobert E. Axelrod David W. Linville Boggarm S. SettyWilliam Michael Dillard Michael F. Mamayek Charles J. SeyfferCecily M. Grzywacz Phil Maybee Elia M. SterlingEllis G. Guiles, Jr. Siroos Mostaghimi Kong Sang TsoGlenn C. Hourahan Thomas J. Yacobellis ASHRAE and ACCA (www.ashrae.or
18、g, www.acca.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.CONTENTSANSI/ASHRAE/ACCA Standard 180-2012,Standard Practice for Inspection and Maintenanceof Commercial Building
19、HVAC SystemsSECTION PAGEForeword. 21 Purpose 22 Scope . 33 Definitions. 34 Implementation. 35 Required Inspection and Maintenance Tasks 5Table 5-1 Air Distribution Systems. 6Table 5-2 Air Handlers . 7Table 5-3 Boilers 8Table 5-4 ChillersAbsorption 9Table 5-5 ChillersAir-Cooled. 10Table 5-6 ChillersW
20、ater-Cooled .11Table 5-7 Coils and Radiators 12Table 5-8 Condensing Units. 13Table 5-9 Control Systems. 13Table 5-10 Cooling Towers and Evaporative-Cooled Devices. 14Table 5-11 Dehumidification and Humidification Devices 14Table 5-12 EconomizersAir-Side 15Table 5-13 Engines, Microturbines. 15Table 5
21、-14 Fans (e.g., Exhaust, Supply, Transfer, Return) 16Table 5-15 Fan-Coils, Hot Water, and Steam Unit Heaters . 17Table 5-16 Furnaces, Combustion Unit Heaters 18Table 5-17 HVAC Water Distribution Systems. 19Table 5-18 Indoor Section Duct-Free Splits . 20Table 5-19 Outdoor Air Heat Exchanging Systems
22、21Table 5-20 PTACs/PTHPs (Package Terminal Air Conditioners or Heat Pumps) . 22Table 5-21 Pumps 22Table 5-22 Rooftop Units . 23Table 5-23 Steam Distribution Systems. 24Table 5-24 Terminal and Control Boxes (e.g., VAV, Fan-Powered, Bypass). 24Table 5-25 Water-Source Heat Pumps 25Informative Appendix
23、ASources of Performance Objectives 26Informative Appendix BIdentifying Indicators of Unacceptable Conditions.26Informative Appendix CBibliography.26Informative Appendix DAddenda Description Information 29NOTEApproved addenda, errata, or interpretations for this standard can be downloaded free of cha
24、rge from the ASHRAEWeb site at www.ashrae.org/technology. 2012 ASHRAE and ACCAASHRAE1791 Tullie Circle NEAtlanta, GA 30329www.ashrae.orgACCA2800 Shirlington Road, Ste. 300Arlington, VA 22206www.acca.orgAll rights reserved. ASHRAE and ACCA (www.ashrae.org, www.acca.org). For personal use only. Additi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASHRAE1802012STANDARDPRACTICEFORINSPECTIONANDMAINTENANCEOFCOMMERCIALBUILDINGHVACSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-431474.html