《ANSI ASA S1.40-2006 AMERICAN NATIONAL STANDARD Specifications and Verification Procedures for Sound Calibrators《声音校准器的规格和核查程序》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASA S1.40-2006 AMERICAN NATIONAL STANDARD Specifications and Verification Procedures for Sound Calibrators《声音校准器的规格和核查程序》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI S1.40-2006 (Revision of ANSI S1.40-1984) AMERICAN NATIONAL STANDARD Specifications and Verification Procedures for Sound CalibratorsAccredited Standards Committee S1, Acoustics Standards Secretariat Acoustical Society of America 35 Pinelawn Road, Suite 114 E Melville, NY 11747-3177ANSI S1.40-2
2、006 Reaffirmed by ANSI on October 27, 2011 5HDIILUPHGE$16,6HSWHPEHUThe American National Standards Institute, Inc. (ANSI) is the national coordinator of voluntary standards development and the clearinghouse in the U.S.A. for information on national and international standards. The Acoustical Society
3、 of America (ASA) is an organization of scientists and engineers formed in 1929 to increase and diffuse the knowledge of acoustics and to promote its practical applications. ANSI S1.40-2006 (Revision of ANSI S1.40-1984) AMERICAN NATIONAL STANDARD Specifications and Verification Procedures for Sound
4、Calibrators Secretariat Acoustical Society of America Approved 20 September 2006: American National Standards Institute, Inc. Abstract This Standard specifies performance requirements for coupler-type sound calibrators. It replaces ANSI S1.40-1984 American National Standard Specifications for Acoust
5、ical Calibrators, and is technically equivalent (except for the absence of requirements for radio-frequency emissions) to International Standard IEC 60942:2003, ElectroacousticsSound calibrators. The standard specifies performance requirements for the sound pressure level, frequency, and total disto
6、rtion generated by a sound calibrator. It also provides requirements for the influence of environmental conditions, for electromagnetic compatibility, and for instrument marking and documentation. The standard gives details of the tests necessary to verify that a model of sound calibrator conforms t
7、o all the requirements, as well as details of the method for periodic testing of a sound calibrator. The tests require the determination of the actual uncertainties of measurement which are to not exceed the maximum uncertainties allowed for laboratory measurements. AMERICAN NATIONAL STANDARDS ON AC
8、OUSTICS The Acoustical Society of America (ASA) provides the Secretariat for Accredited Standards Committees S1 on Acoustics, S2 on Mechanical Vibration and Shock, S3 on Bioacoustics, and S12 on Noise. These committees have wide representation from the technical community (manufacturers, consumers,
9、trade associations, organizations with a general interest, and government representatives). The standards are published by the Acoustical Society of America as American National Standards after approval by their respective Standards Committees and the American National Standards Institute. These sta
10、ndards are developed and published as a public service to provide standards useful to the public, industry, and consumers, and to Federal, State, and local governments. Each of the accredited Standards Committees operating in accordance with procedures approved by American National Standards Institu
11、te (ANSI) is responsible for developing, voting upon, and maintaining or revising its own Standards. The ASA Standards Secretariat administers Committee organization and activity and provides liaison between the Accredited Standards Committees and ANSI. After the Standards have been produced and ado
12、pted by the Accredited Standards Committees, and approved as American National Standards by ANSI, the ASA Standards Secretariat arranges for their publication and distribution. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus
13、 is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and object
14、ions be considered and that a concerted effort be made towards their resolution. The use of an American National Standard is completely voluntary. Their existence does not in any respect preclude anyone, whether he or she has approved the Standards or not, from manufacturing, marketing, purchasing,
15、or using products, processes, or procedures not conforming to the Standards. NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this St
16、andard. Acoustical Society of America ASA Secretariat 35 Pinelawn Road, Suite 114E Melville, New York 11747-3177 Telephone: 1 (631) 390-0215 Fax: 1 (631) 390-0217 E-mail: asastdsaip.org 2006 by Acoustical Society of America. This Standard may not be reproduced in whole or in part in any form for sal
17、e, promotion, or any commercial purpose, or any purpose not falling within the provisions of the U.S. Copyright Act of 1976, without prior written permission of the publisher. For permission, address a request to the Standards Secretariat of the Acoustical Society of America. Acoustical Society of A
18、merica 2006 All rights reserved iContents 1 Scope . 1 2 Normative references. 2 3 Terms and definitions. 2 4 Reference environmental conditions 4 5 Requirements . 4 5.1 General . 4 5.2 Sound pressure level 6 5.3 Frequency. 8 5.4 Influence of static pressure, air temperature, and humidity 9 5.5 Total
19、 distortion 10 5.6 Power supply 11 5.7 Specification and calibration of microphones . 11 5.8 Electromagnetic compatibility . 12 6 Instrument marking and documentation. 13 6.1 Marking . 13 6.2 Individual calibration chart for a class LS sound calibrator 13 6.3 Instruction Manual 13 Annex A (normative
20、) Verification. 16 A.1 Introduction. 16 A.2 Verification sample size 16 A.3 Principal values. 17 A.4 Marking of the sound calibrator and supplied documentation 17 A.5 Performance tests at and around reference environmental conditions 17 A.6 Environmental tests 23 A.7 Electromagnetic compatibility .
21、32 Annex B (normative) Periodic tests . 35 B.1 Introduction. 35 B.2 Submission for test . 35 B.3 Preliminary inspection. 35 B.4 Performance tests. 36 B.5 Calibration of the sound calibrator with other models of microphone 38 B.6 Documentation 39 B.7 Bibliography for Annex B 40 Acoustical Society of
22、America 2006 All rights reserved ii Tables Table 1 Tolerance limits for sound pressure level and short-term level fluctuation, at and around reference environmental conditions . 7 Table 2 Tolerance limits for the influence of supply voltage on sound pressure level, at and around reference environmen
23、tal conditions . 7 Table 3 Tolerance limits for frequency, at and around reference environmental conditions. 8 Table 4 Tolerance limits for sound pressure level, over the specified range of environmental conditions . 9 Table 5 Tolerance limits for frequency, over the specified range of environmental
24、 conditions. 10 Table 6 Maximum total distortion 11 Table A.1 Maximum permitted expanded uncertainty of measurement for sound pressure level and short-term level fluctuation, at and around reference environmental conditions . 20 Table A.2 Maximum permitted expanded uncertainty of measurement for fre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASAS1402006AMERICANNATIONALSTANDARDSPECIFICATIONSANDVERIFICATIONPROCEDURESFORSOUNDCALIBRATORS 声音

链接地址:http://www.mydoc123.com/p-431107.html