ANSI ASA S1.14-1998 American National Standard Recommendations for Specifying and Testing the Susceptibility of Acoustical Instruments to Radiated Radio-Frequency Electromagnetic F.pdf
《ANSI ASA S1.14-1998 American National Standard Recommendations for Specifying and Testing the Susceptibility of Acoustical Instruments to Radiated Radio-Frequency Electromagnetic F.pdf》由会员分享,可在线阅读,更多相关《ANSI ASA S1.14-1998 American National Standard Recommendations for Specifying and Testing the Susceptibility of Acoustical Instruments to Radiated Radio-Frequency Electromagnetic F.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、AMERICAN NATIONAL STANDARDRECOMMENDATIONS FORSPECIFYING AND TESTING THESUSCEPTIBILITY OF ACOUSTICALINSTRUMENTS TO RADIATED RADIO-FREQUENCY ELECTROMAGNETICFIELDS, 25 MHZ TO1GHZAccredited Standards Committee S1, AcousticsStandards SecretariatAcoustical Society of America120 Wall Street, 32nd FloorNew
2、York, New York 10005-3993ANSI / ASA S1.14-1998ANSI/ASAS1.14-1998Reaffirmed by ANSIon 28 February 2003Reaffirmed by ANSI April 25, 2008Reaffirmed by ANSI June 26, 2013 The American National Standards Institute, Inc. (ANSI) is the na-tional coordinator of voluntary standards development and the clear-
3、inghouse in the U.S. for information on national and internationalstandards.The Acoustical Society of America (ASA) is an organization of sci-entists and engineers formed in 1929 to increase and diffuse theknowledge of acoustics and to promote its practical applications.American National StandardRec
4、ommendations for Specifyingand Testing the Susceptibilityof Acoustical Instruments to RadiatedRadio-frequency Electromagnetic Fields,25 MHz to 1 GHzSecretariatAcoustical Society of AmericaApproved 7 July 1998American National Standards Institute, Inc.AbstractThis Standard provides recommendations fo
5、r specifying and testing the susceptibility of acousticalinstruments to radiated radio-frequency electromagnetic fields. This Standard does not containrecommendations regarding the susceptibility of an instrument to conducted electromagnetic fields, orrecommendations to limit the emission of electro
6、magnetic fields from instruments. The Standard coverstwo ranges of radio frequencies for the carrier signal: 25 MHz to 500 MHz, and an extended range from 25MHz to 1 GHz. Recommended maximum electric field strengths for the radio-frequency field are 3 V/m,10 V/m, and 61.4 V/m. An electric field stre
7、ngth greater than 61.4 V/m may be selected for specificapplications. The Standard recommends limits, relative to the overall performance category of anacoustical instrument, of allowable deviation from nominal performance in the absence of aradio-frequency field.ANSI S1.14-1998AMERICAN NATIONAL STAN
8、DARDS ON ACOUSTICSThe Acoustical Society of America (ASA) provides the Secretariat for AccreditedStandards Committees S1 on Acoustics, S2 on Mechanical Vibration and Shock,S3 on Bioacoustics, and S12 on Noise. These committees have wide represen-tation from the technical community (manufacturers, co
9、nsumers, and general-interest representatives). The standards are published by the Acoustical Society ofAmerica through the American Institute of Physics as American National Stan-dards after approval by their respective standards committees and the AmericanNational Standards Institute.These standar
10、ds are developed and published as a public service to providestandards useful to the public, industry, and consumers, and to Federal, State,and local governments.Each of the Accredited Standards Committees operating in accordance with pro-cedures approved by American National Standards Institute (AN
11、SI) is responsiblefor developing, voting upon, and maintaining or revising its own standards. TheASA Standards Secretariat administers committee organization and activity andprovides liaison between the Accredited Standards Committees and ANSI. Afterthe standards have been produced and adopted by th
12、e Accredited StandardsCommittees, and approved as American National Standards by ANSI, the ASAStandards Secretariat arranges for their publication and distribution.An American National Standard implies a consensus of those substantially con-cerned with its scope and provisions. Consensus is establis
13、hed when, in thejudgment of the ANSI Board of Standards Review, substantial agreement hasbeen reached by directly and materially affected interests. Substantial agreementmeans much more than a simple majority, but not necessarily unanimity. Consen-sus requires that all views and objections be consid
14、ered and that a concertedeffort be made towards their resolution.The use of American National Standards is completely voluntary. Their existencedoes not in any respect preclude anyone, whether he or she has approved thestandards or not, from manufacturing, marketing, purchasing, or using products,pr
15、ocesses, or procedures not conforming to the standards.NOTICE: This American National Standard may be revised or withdrawn at anytime. The procedures of the American National Standards Institute require thataction be taken periodically to reaffirm, revise, or withdraw this Standard.Standards Secreta
16、riatAcoustical Society of America120 Wall Street, 32nd FloorNew York, New York 10005-3993USATelephone: 11 212 248 0373Telefax: 11 212 248 0146E-mail: asastdsaip.orgInternet: http:/asa.aip.org 1998 by the Acoustical Society of America. This Standard may not be reproduced inwhole or in part in any for
17、m for sale, promotion, or any commercial purpose, or any purposenot falling within the provisions of the Copyright Act of 1976, without prior written permissionof the publisher. For permission, address a request to the Standards Secretariat of theAcoustical Society of America.ContentsPageForeword .
18、ii0 Introduction 11 Scope . 12 Definitions . 13 Maximum deviation of acoustical signal indication 24 Electromagnetic field parameters . 45 Instruction Manual 5AnnexesA Recommendations for tests to verify conformance of acousticalinstruments to specifications for immunity to radio-frequencyelectromag
19、netic fields . 6B Bibliography . 11Tables1 Recommended limits for the maximum deviation of the signal levelindicated, or produced, by an acoustical instrument . 32 Recommended maximum field strengths for radio-frequencyfields 4A.1 Recommended maximum step increase in the frequency ofsteady-state rad
20、io-frequency fields 10FiguresA.1 Generalized block diagram of equipment for radio-frequencyelectromagnetic-susceptibility tests of a sound-measuringinstrument in a transverse electromagnetic (TEM) cell 7A.2 Generalized block diagram of equipment for electromagnetic-susceptibility tests of a sound-me
21、asuring instrument in a radio-frequency anechoic chamber 8iForewordThis Foreword is for information only and is not an integral part of American NationalStandard Recommendations for Specifying and Testing the Susceptibility of AcousticalInstruments to Radiated Radio-frequency Electromagnetic Fields,
22、 25 MHz to 1 GHz,ANSIS1.14-1998.This Standard was developed under the jurisdiction of Accredited Standards Com-mittee S1, Acoustics, which has the following scope:Standards, specifications, methods of measurement and test, and terminologyin the fields of physical acoustics including architectural ac
23、oustics, electro-acoustics, sonics and ultrasonics, and underwater sound, but excluding thoseaspects which pertain to biological safety, tolerance, and comfort.At the time this Standard was submitted to Accredited Standards Committee S1,Acoustics, for final approval, the membership was as follows:J.
24、 P. Seiler, ChairG. S. K. Wong, Vice ChairA. Brenig, SecretaryAcoustical Society of America J.P.SeilerG. S. K. Wong (Alt.)Air-conditioning and Refrigeration Institute ARI . S.WangS. Sanders (Alt.)American Industrial Hygiene Association L.H.RoysterJ. F. Meagher (Alt.)AT Fax 11 212 248 0146.iiiAmerica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASAS1141998AMERICANNATIONALSTANDARDRECOMMENDATIONSFORSPECIFYINGANDTESTINGTHESUSCEPTIBILITYOFACOUSTICALINSTRUMENTSTORADIATEDRADIOFREQUENCYELECTROMAGNETICFPDF

链接地址:http://www.mydoc123.com/p-431095.html