《ANSI American Society of Sanitary Engineering 1050-2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems.pdf》由会员分享,可在线阅读,更多相关《ANSI American Society of Sanitary Engineering 1050-2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Stack Air Admittance Valves for Sanitary Drainage Systems 1ASSE Standard 1050 - 2009Performance Requirements forStack Air Admittance Valves for Sanitary Drainage SystemsAmerican Society of Sanitary EngineeringASSE Standard #1050-2009ASSE Board Approved: May, 2009 ANSI Approved: January, 2010An Ameri
2、can National StandardStack Air Admittance Valves for Sanitary Drainage Systems iASSE Standard 1050 - 2009American Society of Sanitary EngineeringWestlake, OhioCopyright 2009, 2002, 1990All rights reserved.Neither this standard, nor any portion thereof, may be reproduced without the written consent o
3、f the American Society of Sanitary Engineering.No product may be said to be ASSE approved unless the manufacturer has applied to the ASSE, has had his product tested according to the applicable ASSE standards, and when the product has passed the test, displays the ASSE Seal on the product.Instructio
4、ns for receiving the authorization to display the ASSE Seal are available from ASSEs International Office. Organizations wishing to adopt or list any ASSE standard should print the ASSE standard number on the cover page first and in equal or larger type to that of the adopting or listing organizatio
5、n.General Informationii Stack Air Admittance Valves for Sanitary Drainage SystemsASSE Standard 1050 - 2009Stack Air Admittance Valves for Sanitary Drainage Systems iiiASSE Standard 1050 - 2009This foreword shall not be considered a part of the standard, however, it is offered to provide background i
6、nformation.ASSE standards are developed in the interest of consumer safety.ASSE considers product performance standards to be of great value in the development of improved plumbing systems.AAVs open to the atmosphere when a negative pressure is created within the stack by flow of waste water, and ar
7、e installed at the top of stacks to relieve the negative pressures in the DWV system. An AAV is a one-way valve designed to allow air to enter the plumbing drain-age system when a negative pressure develops in the piping. The device shall be closed at zero differential pressure and under conditions
8、of positive internal pressure.See ASSE Standard #1051-year for the performance requirements for Fixture and Branch Type Air Admittance Valves for Sanitary Drainage Systems.The working group which developed this standard revision, was set up within the framework of the Product Standards Committee of
9、the American Society of Sanitary Engineering.Recognition is made of the time volunteered by members of this working group and of the support of the manufacturers who also participated in the meetings for this standard.This standard does not imply ASSEs endorsement of a product which conforms to thes
10、e requirements.Compliance with this standard does not imply acceptance by any code body.It is recommended that these devices be installed consistent with local codes by qualified and trained professionals.This standard was promulgated in accordance with procedures developed by the American National
11、Standards Institute (ANSI).Forewordiv Stack Air Admittance Valves for Sanitary Drainage SystemsASSE Standard 1050 - 2009Stack Air Admittance Valves for Sanitary Drainage Systems vASSE Standard 1050 - 2009Edward J. LyczkoProduct Standards Committee ChairmanCleveland ClinicCleveland, OhioRand H. Ackro
12、ydRand Technical Consulting, LLCNewburyport, MassachusettsWilliam Briggs, Jr.MGJ Associates New York, New YorkJudson W. CollinsJULYCO ProfessionalsMannford, OklahomaA. Richard EmmersonGeneral InterestBuffalo Grove, IllinoisRon GeorgeRon George Design they only allow air to enter the system. These de
13、vices are designed to be installed on stacks where branches on multiple floors are connected. When these devices are installed in a building, there shall be at least one (1) open vent terminal to relieve positive pressure which extends to the atmosphere outside of the building serving the building d
14、rain on which these devices are installed. 1.2 Scope1.2.1 DescriptionThese devices consist of a one-way valve designed to allow air to enter the plumbing drainage system when a pressure less than atmospheric develops. The device closes and seals by gravity under zero (0) differential pressure (stati
15、c condition) and under positive pressure. These devices prevent sewer gases from entering a building. The device consists of a hooded or shielded body which contains a movable sealing assembly which seats and seals air flow when closed and allows air to enter when open. 1.2.2 Temperature RangeThese
16、devices shall function at temperatures from -40.0F to 150.0F (-40.0C to 65.6C).1.2.3 RatingThese devices shall, at a minimum, pass the required volume of air according to Table 1 at -1.0 inch (-25.4 mm) water column.Table 1Stack AAV Capacity Requirements at 1.0 Inch (25.4 mm) of WaterDrainage Stack
17、Pipe SizeMinimum Airflow Requirement Maximum DFUsIPS inchesDN mm CFM L/s Total for stack of 3 branch intervals or lessTotal for stack greater than 3 branch intervals1 40 4.0 1.9 4 82 50 8.0 3.8 10 242 65 12.0 5.7 20 423.0 75 23.0 10.9 48 724.0 100 47.0 22.2 240 5002 Stack Air Admittance Valves for S
18、anitary Drainage SystemsASSE Standard 1050 - 20091.3 Construction 1.3.1 Air Inlet ShieldsAir inlets of the device shall be shielded to prevent inlet fouling. Air inlet shields shall extend down the body of the device, over the sealing membrane, to the lowest portion of the sealing membrane, and shal
19、l maintain a minimum of 1/16 inch (1.6 mm) clearance between the inner lower edge of the shield and the lowest surface of the air opening of the sealing membrane.1.3.2 LeakageThe device and joining methods shall not permit air leakage when pressurized up to 30.0 inches (762.0 mm) water column.1.3.3
20、InterferenceThe end connection of the device shall be designed so that when installed, the joint shall not interfere with any moving parts of the device or restrict air passageways.1.3.4 Connections1.3.4.1 Threads for Air Admittance ValvesFor all plastic devices having taper pipe threads for connect
21、ion to the drainage system, threads shall conform to the requirement of ASTM Specification F 1498. Metallic threads shall conform to the requirements of ASME B1.20.1.1.3.4.2 Hubless Connectors Hubless connectors shall comply with ASTM C-564, CSA B602, or FM 1680.1.3.4.3 Dimensions and Tolerances for
22、 AAV SocketsSockets on the device shall conform to applicable material requirements. Devices having sock-ets made from ABS material shall conform to the requirements of ASTM Specification D 2661, with the exception of wall thickness. Devices having sockets and made from PVC material shall conform to
23、 the requirements of ASTM Specification D 2665, with the exception of wall thickness. 1.3.4.4 Other ConnectionsWhere types of connections other than connections specified in Sections 1.3.4.1, 1.3.4.2, and 1.3.4.3 are provided with the device, the connection shall conform to the applicable material r
24、equirements and the total assembly shall comply with the performance tests in this standard.1.4 Reference StandardsReferences to industry standards shall mean the latest edition.Stack Air Admittance Valves for Sanitary Drainage Systems 3ASSE Standard 1050 - 2009Section II 2.0 Test Specimens2.1 Sampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAMERICANSOCIETYOFSANITARYENGINEERING10502009PERFORMANCEREQUIREMENTSFORSTACKAIRADMITTANCEVALVESFORSANITARYDRAINAGESYSTEMSPDF

链接地址:http://www.mydoc123.com/p-430861.html