《ANSI American Society of Sanitary Engineering 1044-2015 Performance Requirements for Trap Seal Primer - Drainage Types and Electric Design Types.pdf》由会员分享,可在线阅读,更多相关《ANSI American Society of Sanitary Engineering 1044-2015 Performance Requirements for Trap Seal Primer - Drainage Types and Electric Design Types.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Performance Requirements for Trap Seal Primer Drainage Types and Electric Design TypesASSE InternationalASSE Standard #1044-2015ASSE Board Approved: March 2015ANSI Approved: March 2015An American National StandardTrap Seal Primer Drainage Types and Electric Design Types iASSE Standard #1044-2015ASSE
2、 InternationalMokena, ILCopyright 2015, 2001, 1986All rights reserved.Neither this standard, nor any portion thereof, may be reproduced without the written consent of ASSE International.No product may be said to be listed by ASSE unless the manufacturer has applied to ASSE International, has had the
3、 product tested according to the applicable standards, and when the product has passed the test, displays the ASSE Seal on the product.Instructions for receiving the authorization to display the seal are available from the ASSE International office. Organizations wishing to adopt or list any ASSE st
4、andard should print the ASSE standard number on the cover page first in equal or larger type to that of the adopting or listing organization.General Informationii Trap Seal Primer Drainage Types and Electric Design Types ASSE Standard #1044-2015This foreword shall not be considered a part of the sta
5、ndard. However, it is offered to provide background information.ASSE standards are developed in the interest of consumer safety. The ASSE Product Standards Committee encourages manufacturers to develop performance requirement standards and testing procedures for their products. These standards have
6、the consensus of manufacturers and others who have pertinent interests in plumbing systems and are acceptable to this organization.For many years, the method of priming traps has been with the use of a water supply trap primer, which is activated by flow in the water supply piping. This method of pr
7、iming utilizes primers that comply with ASSE 1018, Performance Requirements for Trap Seal Primer Valves Potable Water Supplied. This standard addresses alternate methods to ASSE 1018 and addresses trap primers utilizing electric design and drainage-type trap seal primers.Although many of the materia
8、l specifications are detailed within Section 4.1 of this standard, it is the responsibility of the manufacturer and the installer to comply with the relevant jurisdictional requirements.The ASSE 1044 working group, which developed this standard revision, was set up within the framework of the ASSE I
9、nternational Product Standards Committee.Recognition is made of the time volunteered by members of the working group and of the support of manufacturers, who also participated in the meetings for this standard.This standard does not imply ASSE Internationals endorsement of a product that conforms to
10、 these requirements. Compliance with this standard does not imply acceptance by any code body.It is recommended that these trap seal primers be installed, consistent with local codes, by qualified and trained professionals.This standard was promulgated in accordance with procedures developed by the
11、American National Standards Institute (ANSI).This edition of the standard was approved by the ASSE International Product Standards Committee on Nov. 13, 2014 and approved by the Board of Directors on March 4, 2015 as an ASSE standard. ForewordTrap Seal Primer Drainage Types and Electric Design Types
12、 iiiASSE Standard #1044-2015iv Trap Seal Primer Drainage Types and Electric Design Types ASSE Standard #1044-2015Edward J. Lyczko, ChairpersonCleveland Clinic Retiree Cleveland, OHWilliam Briggs Jr.MGJ AssociatesNew York, NYTerry BurgerCSA GroupIndependence, OHMaribel CamposICC Evaluation ServicesWh
13、ittier, CAWilliam ChapinProfessional Code Consulting, LLCCullman, ALRon GeorgePlumb-Tech Design b) Those that are used in conjunction with ballcock assemblies;c) Those that receive flow from flushometer valves; andd) Those electric trap seal primers that discharge water automatically and are upstrea
14、m of the air gap or vacuum breaker.1.2.2 Fixture Connected TypeTubing size shall be not less than 1 NPS (32 DN) nominal size. Makeup water supply connection shall be a minimum of NPS (10 DN) nominal size.1.2.3 Ballcock Connected TypeMakeup water supply connections to the refill tube shall not be les
15、s than NPS (8 DN) nominal size.1.2.4 Flushometer Connected TypeMakeup type water supply connections shall be a minimum of NPS (10 DN) nominal size of chrome-plated copper, brass or stainless steel.1.2.5 Electric TypeThe minimum inlet size shall be NPS (15 DN). The minimum outlet size shall be NPS (1
16、0 DN)1.2.6 Working PressurePressurized trap seal primers shall be designed for a working water pressure range of 25.0 to 125.0 psi (172 to 861.8 kPa). 2 Trap Seal Primer Drainage Types and Electric Design Types ASSE Standard #1044-20151.2.7 Connections1.2.7.1 Tapered pipe threads shall comply with A
17、SME B1.20.1.1.2.7.2 Dry seal pipe threads shall comply with ASME B1.20.3.1.2.7.3 Compression assemblies shall comply with SAE J 512.1.2.7.4 Solder connection fittings shall comply with ASME B16.18, ASME B16.22, ASME B16.23 or ASME B16.29. 1.2.8 Fixture Tailpiece Trap Seal PrimersFixture trap or tail
18、piece trap seal primers shall consist of a 1 inch (32 mm) or larger tailpiece or trap assembly that is designed to connect to a supply tube that drains to the floor drain trap inlet.1.2.9 Ballcock Trap Seal PrimersBallcock trap seal primers shall consist of a refill tube diversion mechanism, a close
19、 coupled tank bolt/drain assembly, and related fittings for connection to the closet tank and ballcock. The diversion refill tube assembly shall be fitted with clear vinyl tubing, not less than inch (6.4 mm) inside diameter from the point of connection to the check member, a inch (6.4 mm) tee fittin
20、g, a check valve and a flow restrictor. Connections from the outlet of the close coupled tank connector tube shall not be less than inch (9.5 mm) outside diameter.1.2.9.1 Ballcock trap seal primer shall be used in conjunction with anti-siphon fill valves complying with ASSE 1002.1.2.10 Flushometer T
21、ailpiece/Trap Seal PrimersFlushometer tailpiece/trap seal primers shall be chrome-plated with minimum tailpiece wall thickness of 0.040 inch (1.0 mm) with a minimum inch (9.5 mm) outside diameter compression type chrome-plated brass fitting. Compression fittings shall comply with SAE J512.1.2.10.1 F
22、lushometer Tailpiece/Trap Seal Primer UseFlushometer tailpiece/trap seal primers shall only be used in conjunction with a flushometer complying with ASSE 1037 and shall be installed below the critical level of the vacuum breaker.1.2.11 Electric Trap Seal Primers1.2.11.1 Electric Trap Priming Assembl
23、yElectric trap priming assemblies shall comply with one or more of the following standards:a) UL 1951, Standard for Electric Plumbing Accessoriesb) CSA-C22.2 No. 68, Motor-Operated Appliances (Household and Commercial)1.2.11.2 Backflow ProtectionBackflow protection shall be installed at the discharg
24、e point and comply with ASSE 1001 or ASME A112.1.2.1.3 Reference Standards ASME A112.1.2-2012, Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water-Connected Receptors ASME B1.20.1-2013, Pipe Threads, General Purpose (Inch) ASME B1.20.3-1976 (R2013), Dryseal Pipe Threads (Inch) ASME B16.18-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAMERICANSOCIETYOFSANITARYENGINEERING10442015PERFORMANCEREQUIREMENTSFORTRAPSEALPRIMERDRAINAGETYPESANDELECTRICDESIGNTYPESPDF

链接地址:http://www.mydoc123.com/p-430857.html