ANSI AHRI 420-2008 Performance Rating of Forced-Circulation Free-Delivery Unit Coolers for Refrigeration.pdf
《ANSI AHRI 420-2008 Performance Rating of Forced-Circulation Free-Delivery Unit Coolers for Refrigeration.pdf》由会员分享,可在线阅读,更多相关《ANSI AHRI 420-2008 Performance Rating of Forced-Circulation Free-Delivery Unit Coolers for Refrigeration.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/AHRI Standard 420 (Formerly ARI Standard 420) 2008 Standard for Performance Rating of Forced-Circulation Free-Delivery Unit Coolers for Refrigeration Price $10.00 (M) $20.00 (NM) Copyright 2008, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United State
2、s Patent and Trademark Office IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that
3、products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and
4、accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 420-2000. TABLE OF CONTENTS Section 1 Purpose 1 Section 2 Scope .1 Section 3 Definitions.1 Sect
5、ion 4 Test Requirements 3 Section 5 Rating Requirements .4 Section 6 Minimum Data Requirements for Published Ratings .5 Section 7 Marking and Nameplate Data .5 Section 8 Conformance Conditions 5 TABLES Table 1 Standard Rating Conditions 3 Table 2 Instrumentation Accuracy .4 APPENDICES Appendix A Ref
6、erences Normative 6 Appendix B References Informative 6 Appendix C Methods of Testing Forced-Circulation Free-Delivery Unit Coolers for Refrigeration Normative 7 TABLES FOR APPENDICES Table C1 Test Readings 9 Table C2 Additional Test Conditions .11 Table C3 Test Condition Tolerances 11 Table C4 Refr
7、igerant Temperature Tolerances . 12 FIGURES FOR APPENDICES Figure C1 Method 1: DX Dual Instrumentation .24 Figure C2 Method 2: DX Calibrated Box. 25 Figure C3 Method 3: Liquid Overfeed 26 ANSI/AHRI STANDARD 420-2008 1 PERFORMANCE RATING OF FORCED-CIRCULATION FREE-DELIVERY UNIT COOLERS FOR REFRIGERAT
8、ION Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Forced-Circulation Free-Delivery Unit Coolers for Refrigeration: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance cond
9、itions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard app
10、lies to factory-made, Forced-Circulation, Free-Delivery Unit Coolers, as defined in Section 3, operating with a Volatile Refrigerant fed by either direct expansion or liquid overfeed at wet and/or dry conditions. 2.1.1 Exclusions. This standard does not apply to: 2.1.1.1 Air-conditioning units used
11、primarily for comfort cooling for which testing methods are given in other standards. 2.1.1.2 Unit Coolers operating at latent load conditions with Refrigerant Saturation Temperature 32 F 0.0 C to prevent frost. 2.1.1.3 Unit Coolers installed in or connected to ductwork. 2.1.1.4 Unit Coolers using z
12、eotropic refrigerants with Glides greater than 2.0 F 1.1 C. 2.1.1.5 Field testing of Unit Coolers. Section 3. Definitions All terms in this document follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unles
13、s otherwise defined in this section. 3.1 Dew Point. Refrigerant vapor saturation temperature at a specified pressure. 3.2 Enthalpy Difference (HD). The difference between the enthalpy of the air entering the Unit Cooler and the calculated enthalpy of saturated air at the Refrigerant Saturation Tempe
14、rature at the Unit Cooler outlet, Btu/lb J/kg. 3.3 Forced-Circulation Free-Delivery Unit Coolers (Unit Coolers). A factory-made assembly, including means for forced air circulation and elements by which heat is transferred from air to refrigerant without any element external to the cooler imposing a
15、ir resistance. These may also be referred to as Air Coolers, Cooling Units, Air Units or Evaporators. 3.3.1 Direct Expansion Unit Cooler. A Unit Cooler in which the leaving refrigerant vapor is superheated. 3.3.2 Liquid Overfeed Unit Cooler. A Unit Cooler in which the refrigerant liquid is supplied
16、at a Recirculation Rate greater than 1. 3.4 Glide. The absolute value of the difference between the starting and ending temperatures of a phase-change process (condensation or evaporation) for a zeotropic refrigerant exclusive of any liquid subcooling or vapor superheating. ANSI/AHRI STANDARD 420-20
17、08 2 3.5 Gross Total Cooling Effect (Cooling Capacity). The heat absorbed by the refrigerant, Btu/h W. This is the sum of the Net Total Cooling Effect and the heat equivalent of the energy required to operate the Unit Cooler. This includes both sensible and latent cooling. 3.6 Net Total Cooling Effe
18、ct. The refrigeration capacity available for space and product cooling, Btu/h W. It is equal to the Gross Total Cooling Effect less the heat equivalent of energy required to operate the Unit Cooler. This includes both sensible and latent cooling. 3.7 Overfeed Ratio. The mass ratio of liquid to vapor
19、 at the outlet of the Liquid Overfeed Unit Cooler. This may also be referred to as overfeed rate. 3.8 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to
20、 all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature, controlled by the manufacturer, at stated R
21、ating Conditions. 3.8.1 Application Rating. A rating at conditions other than Standard Rating Conditions. 3.8.2 Standard Rating. A rating at one of the Standard Rating Conditions shown in Table 1 that is an accurate representation of test data. 3.9 Rated Power. 3.9.1 For single phase motors, total f
22、an motor input power, W or kW. 3.9.2 For polyphase motors, individual fan motor output power, hp kW. 3.10 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.10.1 Standard Rating Conditions.
23、Rating Conditions listed in Table 1 that can be used as a basis of comparison for performance characteristics. 3.10.1.1 Dry Rating Condition. Rating Condition where latent cooling is not present. 3.10.1.2 Wet Rating Condition. Rating Condition where both sensible and latent cooling are present and t
24、he coil surface temperature is above freezing. 3.11 Recirculation Ratio. (Recirculation Rate) The mass ratio of liquid circulated to the amount of liquid vaporized. 3.12 Refrigerant Saturation Temperature. Refrigerant temperature at the Unit Cooler inlet or outlet determined either by measuring the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAHRI4202008PERFORMANCERATINGOFFORCEDCIRCULATIONFREEDELIVERYUNITCOOLERSFORREFRIGERATIONPDF

链接地址:http://www.mydoc123.com/p-430606.html