ANSI AGMA 2116-A05-2005 Evaluation of Double Flank Testers for Radial Composite Measurement of Gears.pdf
《ANSI AGMA 2116-A05-2005 Evaluation of Double Flank Testers for Radial Composite Measurement of Gears.pdf》由会员分享,可在线阅读,更多相关《ANSI AGMA 2116-A05-2005 Evaluation of Double Flank Testers for Radial Composite Measurement of Gears.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/AGMA 2116-A05Reaffirmed April 2011American National StandardEvaluation of Double FlankTesters for Radial CompositeMeasurement of GearsANSI/AGMA2116-A05iiEvaluation of Double Flank Testers for Radial Composite Measurement ofGearsANSI/AGMA 2116-A05ApprovalofanAmericanNationalStandardrequiresverif
2、icationbyANSIthattherequire-ments for due process, consensus, and other criteria for approval have been met by thestandards developer.Consensusisestablishedwhen,inthejudgmentoftheANSIBoardofStandardsReview,substantial agreement has been reached by directly and materially affected interests.Substanti
3、alagreementmeansmuchmorethanasimplemajority,butnotnecessarilyuna-nimity. Consensus requires that all views and objections be considered, and that aconcerted effort be made toward their resolution.TheuseofAmericanNationalStandardsiscompletelyvoluntary;theirexistencedoesnotin any respect preclude anyo
4、ne, whether he has approved the standards or not, frommanufacturing, marketing, purchasing, or using products, processes, or procedures notconforming to the standards.The American National Standards Institute does not develop standards and will in nocircumstances give an interpretation of any Americ
5、an National Standard. Moreover, noperson shall have the right or authority to issue an interpretation of an American NationalStandardinthenameoftheAmericanNationalStandardsInstitute. Requestsforinterpre-tation of this standard should be addressed to the American Gear ManufacturersAssociation.CAUTION
6、 NOTICE: AGMA technical publications are subject to constant improvement,revision, or withdrawal as dictated by experience. Any person who refers to any AGMAtechnical publication should be sure that the publication is the latest available from theAssociation on the subject matter.Tablesorotherself-s
7、upportingsectionsmaybereferenced. Citationsshouldread: SeeANSI/AGMA 2116-A05, Evaluation of Double Flank Testers for Radial Composite Mea-surement of Gears, published by the American Gear Manufacturers Association, 500Montgomery Street, Suite 350, Alexandria, Virginia 22314, http:/www.agma.org.Appro
8、ved December 29, 2005ABSTRACTThisstandardprovidestheevaluationcriteriafordoubleflanktesters. Recommendedartifactsizesandgeom-etryareprovidedalongwithmeasurementsystemconditions. Annexesareprovidedformethodsofestimatingcalibration uncertainty and artifact calibration certificates.Published byAmerican
9、 Gear Manufacturers Association500 Montgomery Street, Suite 350, Alexandria, Virginia 22314Copyright 2005 by American Gear Manufacturers AssociationAll rights reserved.No part of this publication may be reproduced in any form, in an electronicretrieval system or otherwise, without prior written perm
10、ission of the publisher.Printed in the United States of AmericaISBN: 1-55589-871-8AmericanNationalStandardANSI/AGMA 2116-A05AMERICAN NATIONAL STANDARDiii AGMA 2005 - All rights reservedContentsForeword iv.1 Scope 1.2 Normative references 1.3 Definition of terms 14 Application 1.5 Condition of the me
11、asurement system 2.6 Environment 3.7Artifacts 3.8 Measurement uncertainty 5AnnexesA Method for estimating uncertainty 6.B Calibration certificate requirements 9Figures1 Hierarchy of calibration 2ANSI/AGMA 2116-A05 AMERICAN NATIONAL STANDARDiv AGMA 2005 - All rights reservedForewordThe foreword, foot
12、notes and annexes, if any, in this document are provided forinformational purposes only and are not to be construed as a part of ANSI/AGMA2116-A05, Evaluation of Double Flank Testers for Radial Composite Measurement ofGears.Between 1994 and 1998, AGMA published three standards on calibration of gear
13、measuringinstruments:ANSI/AGMA2010-A94,MeasuringInstrumentCalibrationPartI,Involute Measurement, ANSI/AGMA 2113-A97, Measuring Instrument Calibration, GearTooth Alignment Measurement, and ANSI/AGMA 2114-A98, Measuring InstrumentCalibration, Gear Pitch and Runout Measurements. These standards covered
14、 elementalmeasurements specified in the accuracy requirements of ANSI/AGMA 2015-1-A01,Accuracy Classification System - Tangential Measurements for Cylindrical Gears.TheCalibration Committee decided that supplemental information, on measurement systemconditions for calibration, accuracy requirements
15、and uncertainty determination, wasdesirabletohaveinanInformationSheet,AGMA931-A02,CalibrationofGearMeasuringInstrumentsandTheirApplicationtotheInspectionofProductGears,thatwaspublishedin2002.The material in these AGMA documents was combined and submitted to ISO for thedevelopment of ISO 18653:2003,
16、Gears - Evaluation of instruments for the measurementofgears,andISO/TR10064-5:2005,Cylindricalgears - Codeofinspectionpractice -Part5: Recommendations relative to evaluation of gear measuring instruments.The Calibration Committee decided that similar standardization and information wasneeded for the
17、 evaluation methods of double flank testers used for radial compositemeasurement of gears. After a study of existing practices, standards, and literature theinformation contained herein is a consolidation of the most common methods currently inexistence.ThefirstdraftofANSI/AGMA2116-A05wasmadeinAugus
18、t,2003. ItwasapprovedbytheAGMA membership in October, 2005. It was approved as an American National Standardon December 29, 2005.Suggestionsfor improvementofthisstandardwillbewelcome. TheyshouldbesenttotheAmericanGearManufacturersAssociation,500MontgomeryStreet,Suite350,Alexandria,Virginia 22314.ANS
19、I/AGMA 2116-A05AMERICAN NATIONAL STANDARDv AGMA 2005 - All rights reservedPERSONNEL of the AGMA Calibration CommitteeChairman: Robert E. Smith R.E. Smith at a minimum to include axis alignment_1)presently at the stage of developmentANSI/AGMA 2116-A05 AMERICAN NATIONAL STANDARD2 AGMA 2005 - All right
20、s reservedand linear measuring system accuracy. Thesemeasurements should include provision for testingthe machine with table loads that represent theweight of product gears being tested.4.2 TraceabilityThetermtraceabilityimpliesanunbrokencalibrationchain from measurements taken on a shop floordouble
21、 flank tester to the primary artifacts at anational laboratory, see figure 1. Traceability istransferred by calibrated artifacts. The primarylaboratoryhasthelowestuncertainty,anduncertain-ty increases at each level as the traceability chain istransferred to shop floor measuring instruments.Minimizin
22、gthestepsfromtheprimarylaboratorytoashop floor double flank tester will reduce themeasurement uncertainty.NationalinstituteCalibrationlaboratoryMeasuring roomGear measuring instrumentProduction, shop floorPrimary artifactReference artifactsWorking artifactsGearsFigure 1 - Hierarchy of calibration4.3
23、 ArtifactsThe artifacts used for these tests shall be of similarsize to product gears inspected on the double flankcompositetester. Artifactsshallbeusedtoevaluatetheaccuracyofeachparameterinspected. Specificartifact requirements are given in clause 7.4.4 Measurement uncertaintyConventional practice
24、recommends the uncertaintyof a measurement process be less than 10% of theparameter tolerance measured, to ensure that thereliable interpretation of the measurement results ispossible. However,thisisnottechnicallyachievablewhen inspecting high accuracy gears.For example, when gears have tolerances b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAGMA2116A052005EVALUATIONOFDOUBLEFLANKTESTERSFORRADIALCOMPOSITEMEASUREMENTOFGEARSPDF

链接地址:http://www.mydoc123.com/p-430537.html