API TR 756-1-2014 Process Plant Tent Responses to Vapor Cloud Explosions-Results of the American Petroleum Institute Tent Testing Program.pdf
《API TR 756-1-2014 Process Plant Tent Responses to Vapor Cloud Explosions-Results of the American Petroleum Institute Tent Testing Program.pdf》由会员分享,可在线阅读,更多相关《API TR 756-1-2014 Process Plant Tent Responses to Vapor Cloud Explosions-Results of the American Petroleum Institute Tent Testing Program.pdf(616页珍藏版)》请在麦多课文档分享上搜索。
1、Process Plant Tent Responses to Vapor Cloud ExplosionsResults of the American Petroleum Institute Tent Testing ProgramAPI TECHNICAL REPORT 756-1SEPTEMBER 2014Process Plant Tent Responses to Vapor Cloud ExplosionsResults of the American Petroleum Institute Tent Testing ProgramDownstream SegmentAPI TE
2、CHNICAL REPORT 756-1SEPTEMBER 2014Prepared for API by:Raymond H. Bennett, P.E., Ph.D.Martin Goodrich, P.E.Brad HornBaker Engineering and Risk Consultants, Inc.3330 Oakwell Court, Suite 100San Antonio, TX 78218Special NotesAPI publications necessarily address problems of a general nature. With respec
3、t to particular circumstances, local,state, and federal laws and regulations should be reviewed.Neither API nor any of APIs employees, subcontractors, consultants, committees, or other assignees make anywarranty or representation, either express or implied, with respect to the accuracy, completeness
4、, or usefulness of theinformation contained herein, or assume any liability or responsibility for any use, or the results of such use, of anyinformation or process disclosed in this publication. Neither API nor any of APIs employees, subcontractors,consultants, or other assignees represent that use
5、of this publication would not infringe upon privately owned rights.API publications may be used by anyone desiring to do so. Every effort has been made by the Institute to assure theaccuracy and reliability of the data contained in them; however, the Institute makes no representation, warranty, orgu
6、arantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss ordamage resulting from its use or for the violation of any authorities having jurisdiction with which this publication mayconflict.API publications are published to facilitate the bro
7、ad availability of proven, sound engineering and operatingpractices. These publications are not intended to obviate the need for applying sound engineering judgmentregarding when and where these publications should be utilized. The formulation and publication of API publicationsis not intended in an
8、y way to inhibit anyone from using any other practices.Any manufacturer marking equipment or materials in conformance with the marking requirements of an API standardis solely responsible for complying with all the applicable requirements of that standard. API does not represent,warrant, or guarante
9、e that such products do in fact conform to the applicable API standard.All rights reserved. No part of this work may be reproduced, translated, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission f
10、rom the publisher. Contact the Publisher, API Publishing Services, 1220 L Street, NW, Washington, DC 20005.Copyright 2014 American Petroleum InstituteForewordNothing contained in any API publication is to be construed as granting any right, by implication or otherwise, for themanufacture, sale, or u
11、se of any method, apparatus, or product covered by letters patent. Neither should anythingcontained in the publication be construed as insuring anyone against liability for infringement of letters patent.Suggested revisions are invited and should be submitted to the Director of Regulatory and Scient
12、ific Affairs, API,1220 L Street, NW, Washington, DC 20005.iiiNOTICE Baker Engineering and Risk Consultants, Inc. (BakerRisk) made every reasonable effort to perform the work contained herein in a manner consistent with high professional standards. The work was conducted on the basis of information m
13、ade available by the client or others to BakerRisk. Neither BakerRisk nor any person acting on its behalf makes any warranty or representation, expressed or implied, with respect to the accuracy, completeness, or usefulness of the information provided. All observations, conclusions and recommendatio
14、ns contained herein are relevant only to the project, and should not be applied to any other facility or operation. Any third party use of this Report or any information or conclusions contained therein shall be at the users sole risk. Such use shall constitute an agreement by the user to release, d
15、efend and indemnify BakerRisk from and against any and all liability in connection therewith (including any liability for special, indirect, incidental or consequential damages), regardless of how such liability may arise. BakerRisk regards the work that it has done as being advisory in nature. The
16、responsibility for use and implementation of the conclusions and recommendations contained herein rests entirely with the client. i EXECUTIVE SUMMARY The American Petroleum Institute (API) contracted with Baker Engineering and Risk Consultants, Inc. (BakerRisk) to perform vapor cloud explosion (VCE)
17、 tests to determine the response of tents to the potential explosion hazards that may be present at refineries, petrochemical and chemical operations, and natural gas and other onshore process facilities covered by OSHA 29 CFR 1910.119. The testing was conducted to provide data for use by the API co
18、mmittee developing API Recommended Practice (RP) 756, “Management of Hazards Associated with Location of Process Plant Tents”. The tests were originally designed to serve multiple purposes: provide data on response of tents to a variety of blast loads ranging from 0.6 psi to 1.5 psi, identify the fa
19、ilure modes for different types of tents, and obtain data on tent response to support estimates on the vulnerability of tent occupants. As the testing was performed, it became apparent that the tents being tested could withstand higher pressures than originally envisioned. The test program was there
20、fore modified to accommodate the observed behavior. The development and modifications to the scope of the test program are discussed in the report. The following three series of tests were conducted. A Series Three types of non-wind rated tents were tested with the long side of the tents facing the
21、blast source. B Series The same types of tents were rotated 90 degrees and retested at higher loads. C Series Three types of engineered tents (designed for 90 mph 3 second wind gusts) were tested at two different pressures. Subsequent to the completion of the API-funded tests, BakerRisk performed tw
22、o additional tests to evaluate the DLG performance, as internal research. The response of the tents in these internal research tests, including the response of contents added to the tents, is discussed in this report. The Explosion Research Cooperative (ERC) participants voted to release the data fr
23、om a series of shock tube tests performed under their sponsorship that addressed the potential for the contents of a tent to become airborne. The data, in term of object mass and velocity, are provided in this report. This report presents data only and does not provide any summary or conclusions on
24、the acceptability of a tent siting approach. ii Table of Contents EXECUTIVE SUMMARY . I 1 INTRODUCTION AND BACKGROUND 1 2 OVERVIEW AND DEVELOPMENT OF THE API TEST PROGRAM . 2 2.1 Originally Planned Test Matrix . 2 2.2 Final Test Matrix 4 2.3 Instrumentation and Camera Coverage . 6 2.3.1 Instrumentat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- APITR75612014PROCESSPLANTTENTRESPONSESTOVAPORCLOUDEXPLOSIONSRESULTSOFTHEAMERICANPETROLEUMINSTITUTETENTTESTINGPROGRAMPDF

链接地址:http://www.mydoc123.com/p-430199.html