AIR FORCE MIL-STD-1289 D CHG NOTICE 1-2004 AIRBORNE STORES GROUND FIT AND COMPATIBILITY REQUIREMENTS《机载外挂物 接地设置及兼容性要求》.pdf
《AIR FORCE MIL-STD-1289 D CHG NOTICE 1-2004 AIRBORNE STORES GROUND FIT AND COMPATIBILITY REQUIREMENTS《机载外挂物 接地设置及兼容性要求》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-STD-1289 D CHG NOTICE 1-2004 AIRBORNE STORES GROUND FIT AND COMPATIBILITY REQUIREMENTS《机载外挂物 接地设置及兼容性要求》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-STD-1289D w/CHANGE 1 23 April 2004 SUPERSEDING MIL-STD-1289D 24 September 2003 DEPARTMENT OF DEFENSE STANDARD PRACTICE AIRBORNE STORES, GROUND FIT AND COMPATIBILITY REQUIREMENTS AMSC N/A AREA SESS DISTRIBUTION STATEMENT A: Approved for public release, distribution is unlimited. METRIC Provided
2、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1289D ii FOREWORD 1. This standard is approved for use by all Departments and Agencies of the Department of Defense. 2. The information contained herein constitutes a standardization of procedures and cr
3、iteria for testing ground fit and compatibility of munitions and stores with aircraft and armament weapons support equipment. This document is applicable to all persons in the Aircraft/Stores Compatibility area. It is intended to serve as a means of informing, guiding, and providing instructions in
4、the fundamentals and principles involved in the determination of physical, electrical, and operational compatibility of an airborne store with its associated suspension equipment, support equipment, and with the carriage aircraft. The physical clearances included herein are recommended to prevent an
5、y major interference or damage from developing. If deviations are noted and waivers are necessary they must be justified, documented, and approved by the cognizant authority responsible for the aircraft. 3. Technical questions may be addressed to the following offices: U.S. Army Aviation Missile Com
6、mand Redstone Arsenal AMSAM-RD-AE-S-W Building 4488, Room C-316 Huntsville AL 35898-5000 Telephone: Commercial (256) 705-9765 Air Armament Center 102 West D Ave, Suite 300 Eglin AFB FL 32542-6865 Telephone: Commercial (850) 882-3310 DSN 872-3310/8941 Naval Air Warfare Center Aircraft Division 21960
7、Nickles Rd Patuxent River MD 20670 Telephone: Commercial (301) 342-4340/4382 4. Comments, suggestions, or questions on this document shall be addressed to the Air Force SEEK EAGLE Office, ATTN: SKA, 205 West D Avenue, Eglin AFB FL 32542-6865 or E-mail to brooksjoeglin.af.mil. Since contact informati
8、on can change, you may want to verify the currency of this address information using the ASSIST Online database at www.dodssp.daps.mil Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1289D iii CONTENTS PARAGRAPH PAGE NO. 1. SCOPE1 1.1 Scope.
9、1 1.2 Application. .1 1.3 Exclusions. .1 2. APPLICABLE DOCUMENTS .1 2.1 General.1 2.2 Government documents1 2.2.1 Specifications, standards, and handbooks.1 2.2.2 Other Government documents, drawings, and publications.2 2.3 Order of precedence.2 3. DEFINITIONS2 3.1 Aircraft. .2 3.2 Store.3 4. GENERA
10、L REQUIREMENTS 3 4.1 Store fit and compatibility test configurations. .3 4.2 Store installation requirements3 4.2.1 Loading procedures.3 4.2.2 Alignment of stores3 4.3 Clearances. 4 4.3.1 Loading clearance.4 4.3.2 External store clearances4 4.3.2.1 Store to aircraft clearance. .4 4.3.2.2 Store to st
11、ore clearance. 4 4.3.2.3 Store to pylon clearance.4 4.3.2.4 Rail launched stores clearance.4 4.3.2.5 Store ejection clearance.5 4.3.2.6 Intake duct clearance. 5 4.3.2.7 Store arming control system clearance.5 4.3.2.8 Propeller and rotor disk clearance5 4.3.2.9 Clearance for missile tubes. .5 4.3.3 I
12、nternal store clearances. 5 4.3.3.1 Store to aircraft clearance. .5 4.3.3.2 Store to store clearance. 6 4.3.3.2.1 U.S. Navy requirement6 4.3.3.3 Store to suspension clearance. 6 4.3.3.4 Trapeze and rotary suspension to aircraft clearance. .6 4.3.3.5 Intake duct clearance. 6 4.3.3.6 Store arming cont
13、rol system clearance.6 4.3.3.7 Ejection store clearance. 6 4.3.4 Fuze clearance10 4.3.5 Minimum ground clearance. 10 4.3.6 Landing gear clearance.10 4.3.7 Engine heat, jet, and munitions blast clearance.10 4.3.8 RAM air turbine clearance. 10 4.4 Accessibility. .11 4.4.1 Maintenance access11 Provided
14、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1289D iv CONTENTS PARAGRAPH PAGE NO. 4.4.2 Access for store adjustment. .11 4.5 Sway bracing. .11 4.6 Ejection mechanism11 4.7 Release system electrical devices and wiring. 11 4.8 Armament weapons suppo
15、rt equipment (AWSE) compatibility11 4.8.1 Special tools11 4.8.2 Store cradling or handling area12 4.9 Safety. 12 4.9.1 Ground safety device. .12 4.9.2 Erroneous switch selection and single component failure12 4.9.3 Safetying. 12 5. DETAILED REQUIREMENTS12 5.1 General.12 5.2 Test stores12 5.3 Install
16、ation test methods. 13 5.3.1 Store loading.13 5.3.2 Loading procedure test13 5.3.3 Clearance tests. 13 5.3.4 Accessibility tests. .14 5.3.5 Store reinforced area test14 5.3.6 Electrical function test14 5.3.6.1 Electrical interface14 5.3.6.2 Store functional check. .14 5.3.6.3 Armament control system
17、 check.14 5.3.7 Armament Weapons Support Equipment (AWSE) compatibility test15 5.3.7.1 Test conditions.15 5.4 Documentation of observations.15 5.5 Safety standards.15 6. NOTES 16 6.1 Intended use.16 6.2 Acquisition requirements.16 6.3 Types of tests. 16 6.4 Subject term (keyword list) listing16 6.5
18、International standardization agreements. 17 6.6 Changes from previous issue17 APPENDIX A 18 Test Item Descriptions 18 FIGURES 1. Definition of a five-degree half angle cone (see 4.3.2.8b).10 2. Internal carriage clearance (see 4.3.3.7a).11 3. Internal carriage clearance (see 4.3.3.7b).12 Provided b
19、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-1289D 1 1. SCOPE 1.1 Scope. This standard establishes the requirements and testing procedures for installations of all munitions and stores carried on an aircraft. It includes testing of all stores define
20、d in 3.2. 1.2 Application. The compatibility qualities of every airborne store undergoing test will be demonstrated in accordance with the provisions of this standard, unless specific deviations are noted and waivers are authorized by appropriate service authority or unless special requirements are
21、specified by the development agency. 1.3 Exclusions. The requirements for aircraft electrical circuits, which are a part of the arming, de-arming, and monitoring systems for nuclear bombs, or missiles with nuclear warheads, are excluded from this document. To assure electrical compatibility of nucle
22、ar weapons in those areas, coordination with appropriate nuclear design agencies must be accomplished. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other sections of t
23、his standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they
24、 are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILSTD1289DCHGNOTICE12004AIRBORNESTORESGROUNDFITANDCOMPATIBILITYREQUIREMENTS 机载 外挂 接地 设置 兼容性

链接地址:http://www.mydoc123.com/p-428462.html