AIR FORCE MIL-PRF-9050 G-2009 VALVES OXYGEN PRESSURE RELIEF AIRCRAFT《飞行器用氧气泄压阀》.pdf
《AIR FORCE MIL-PRF-9050 G-2009 VALVES OXYGEN PRESSURE RELIEF AIRCRAFT《飞行器用氧气泄压阀》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-PRF-9050 G-2009 VALVES OXYGEN PRESSURE RELIEF AIRCRAFT《飞行器用氧气泄压阀》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 4820 MIL-PRF-9050G 25 AUGUST 2009 SUPERSEDING MIL-PRF-9050F 26 NOVEMBER 1997 PERFORMANCE SPECIFICATION VALVES, OXYGEN, PRESSURE RELIEF, AIRCRAFT This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification co
2、vers aircraft pressure relief valves for 70 and 300 psig rated liquid oxygen (LOX) converters. 1.2 Classification. The valves will be of the following types and Government designations, as specified (see 6.2): Type PIN Operating Range I M9050-1 80-100 psig II M9050-2 100-120 psig III M9050-3 330-380
3、 psig IV M9050-4 380-430 psig V M9050-5 120-140 psig 1.3 Part or Identifying Number (PIN). The PIN to be used for valve acquired to this specification is created as follows: M 9050 -X Dash number, see 1.2 Specification number Prefix for military specification INCH-POUND Comments, suggestions, or que
4、stions on this document should be addressed to Oklahoma City Air Logistics Center/ENSDAA, 3001 Staff Drive, Tinker AFB, OK 73145 or e-mailed to af71tinker.af.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at
5、 http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-9050G 2 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not in
6、clude documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of the documents cited in sect
7、ions 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications. The following specifications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitati
8、on or contract. COMMERCIAL ITEM DESCRIPTIONS A-A-59503 - Nitrogen, Technical A-A-59155 - Nitrogen, High Purity, Special Purpose (Copies of these documents are available online at http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia,
9、 PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AMERICAN SOCIETY FOR QUALITY (ASQ) ANSI/ASQ Z1.4 - Samplin
10、g Procedures and Tables for Inspection by Attributes (ASQ documents may be obtained at http:/asq.org or addressed to American Society for Quality P.O. Box 3005, Milwaukee, WI 53201-3005 or 600 North Plankinton Avenue, Milwaukee, Wisconsin, 53203, USA) SOCIETY OF AUTOMOTIVE ENGINEERS (SAE) SAE AS8010
11、 - Aviators Breathing Oxygen Purity Standard (SAE documents may be obtained at http:/www.sae.org or from Society of Automotive Engineers, Inc., 400 Commonwealth Drive, Warrendale PA 15069) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-9050G
12、 3 AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM B117 - Salt Spray (Fog) Apparatus, Operating ASTM D1149 - Rubber Deterioration-Surface Ozone Cracking In A Chamber (ASTM documents may be obtained at www.astm.org or addressed to American Society for Testing and Material, 100 Barr Harbor Driv
13、e, West Conshohocken, PA 19428-2959.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes app
14、licable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. Valves furnished under this specification shall be products that are authorized by the qualifying activity for listing on the applicable qualified products list before contract award (see 6
15、.3). 3.2 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advan
16、tageous life cycle cost. 3.3 Materials. All materials shall be corrosion resistant or suitably treated to resist corrosion due to electrolytic decomposition, salt fog, and any other atmospheric condition that may be encountered during operational use or storage. All material used shall be capable of
17、 operating safely in a pure oxygen and LOX environment. The use of toxic chemicals, hazardous substances, or ozone depleting chemicals shall be avoided, whenever feasible. 3.3.1 Ozone resistance. Elastomer materials shall be ozone resistant. 3.3.2 Age. Elastomers, except silicone, shall be no more t
18、han 12 months old from the cure date upon delivery. 3.4 Interface. 3.4.1 Dimensions. The dimensions of the valve shall conform to figure 1. 3.4.2 Threads. All pipe threads shall be in accordance with SAE-AS71051. 3.5 Performance. 3.5.1 Weight. The weight of the valve shall not exceed 0.25 pound. Pro
19、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-9050G 4 3.5.2 Leakage. The valve shall not leak at a rate greater than 0.01 liter per minute (LPM) when subjected to an internal pressure at the minimum operating pressure of the valve (see 1.2) an
20、d after establishing a 15 LPM flow through the valve. 3.5.3 Flow capacity. The valve shall have a minimum gas flow rate of 100 LPM at the maximum operating pressure (see 1.2). 3.5.4 Sustained flow. The valve shall withstand a gas flow rate of 100 LPM for 1 hour without chatter (see 6.6). 3.5.5 Endur
21、ance. The valve shall withstand 5,000 endurance cycles of operation. For each endurance cycle, the valve shall be pressurized from below the minimum operating pressure to the maximum operating pressure and back to below the minimum operating pressure (see 1.2). The valve shall seat each time at the
22、minimum operating pressure. 3.5.6 Overpressure cycling. The valve shall be pressurized from below the minimum operating pressure to a pressure of 50 psig above the maximum operating pressure and back to below the minimum operating pressure (see 1.2). This shall constitute one overpressure cycle. The
23、 valve shall not leak at a rate greater than 0.01 LPM after the 5th, 15th, and 25th pressurization cycles. 3.5.7 Orientation. The valve shall operate in any orientation. 3.5.8 Tamper-proof relief pressure setting mechanism. The valve shall be equipped with a relief pressure setting mechanism which s
24、hall be tamper-proof. 3.5.9 Inlet filter. The inlet of the valve shall have a 75 micron filter or screen to prevent foreign material from entering the valve. 3.6 Environmental conditions. 3.6.1 Temperature. The valve shall operate between LOX exposure temperatures and 265 5F. 3.6.2 Vibration. The va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF9050G2009VALVESOXYGENPRESSURERELIEFAIRCRAFT 飞行 器用 氧气 泄压阀 PDF

链接地址:http://www.mydoc123.com/p-428308.html