AIR FORCE MIL-PRF-83766 B-1997 FILLER AND PRESSURIZATION UNIT HYDRAULIC SYSTEM《液压系统填料和加压机组》.pdf
《AIR FORCE MIL-PRF-83766 B-1997 FILLER AND PRESSURIZATION UNIT HYDRAULIC SYSTEM《液压系统填料和加压机组》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-PRF-83766 B-1997 FILLER AND PRESSURIZATION UNIT HYDRAULIC SYSTEM《液压系统填料和加压机组》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-PRF-837666 m 9999906 2046004 T26 m (INCH-POUNDI MIL-PR.F-83766B 1 August 97 SUPERSEDING 27 December 1984 MIGF-83766A(USAF) PERFORMANCE SPECIFICATION FILLER AND PRESSURIZATION UNIT, HYDRAULIC SYSTEM This specification is approved for use by all Departments and Agencies of the Department of Defens
2、e. 1. SCOPE 1.1 ScoDe. The filler and pressurization unit covered by this document will be operated in hangars, fightlines, and flight decks for servicing aircraft hydraulic systems with pressures from 0- 3,000 psi. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specif
3、ied in sections 3 and 4 of this specification. This section does not include documents in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they mu
4、st meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addresse
5、d to: SA-ALC/TILDD, 485 Quentin Roosevelt Rd., Bldg 171, Kelly AFB, TX 78241-6524 by using the self addressed Standardization Document Improvement Proposal D Form 1426) appearing at the end of this document or by I letter. I AMSC NIA FSC 4910 DISTRIBUTION STATEMENT A. Approved for public release; di
6、stribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-Pm-83766B 2.2.1 SDecifications and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specif
7、ied, the issues of these documents are those listed in the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL ZZ-T-410 Tire, Pneumatic, Industrial MILITARY “H-5606 Hydraulic Fluid, Petroleum Base, A
8、ircraft, Missile, and Ordinance. “P-5515 Pump, Hydraulic, Ram, Hand Driven. STANDARDS FEDERAL FED-STD-595 Colors MLlTARY MS24322 Wheel and Hub Assemblies. AIR FORCE - NAVY AERONAUTICAL AN6248 Pump-Hydraulic Hand, Type 3,000 (Unless otherwise indicated, copies of the above specifications and standard
9、s are available from the Defense Automated Printing Service, Bldg 4D ODSSP), 700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.2.2 Other Government documents, drawinps. and publications. The following other Government documents, drawings, and publications form a part of this document to the exten
10、t specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWINGS AIR FORCE 65534010 Reservoir Assembly, Fluid 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83766B 7545352 Requirements for Finishes,
11、Protective, and Codes for SA-ALC Ground and Ground Support Equipment. 8520434 Handle, Hydraulic Filler-Pressurization Unit (Copies of these drawings are available from SA-ALC/TILDB, Data Repository, Bldg 171,485 Quentin Roosevelt Rd., Kelly AFB, TX 78241-6524.) 2.4 Order of precedence. In the event
12、of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. First article,
13、this document makes provisions for first article testing (see 4.2). 3.2 Material. The unit shall be constructed of components that are corrosion resistant or treated to resist corrosion due to fuels, salt spray, or atmospheric conditions likely to be met in storage or in normal service. All material
14、s of the unit shall be compatible and not affected by hydraulic fluid conforming to MIL-H-4505. 3.3 Finish. Finish shall be to the best commercial practice as supplemented by AF drawing 7545352, use finish codes as required per Table I, color number 24052 per FED-STD-595. 3.4 ComDonents. The filler
15、and pressurization unit shall consist,of the unit being mounted on pneumatic tires, a reservoir (Air Force drawing 65J34010), hand operated high pressure pump, hand operated low pressure pump, line filter, O-5,OOO pounds per square inch (psi) pressure gage, check valve, bleed valves, servicing hose
16、and all accessories thereto necessary for proper and efficient operation. 3.5 Design and construction. The filler and pressurization unit shall be built to withstand the strain, jars, vibrations, and other conditions incident to shipping, storage, and service. The mer and pressurization unit shall b
17、e capable of servicing the hydraulic systems of aircraft which utilize hydraulic fluid conforming to MIL-H-5606. 3.6 Performance. 3.6.1 Operation position. The fier and pressurization unit shall operate satisfactorily while in its normal plane of operation to as much as 10 degrees from horizontal pl
18、ane in any direction. 3.7 Details of ComDonents. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.7.1 Reservoir. A hydraulic fluid reservoir, in accordance with Air Force Drawing 65534010, shall be furnished as an integral part of the fier and pre
19、ssurization unit. The reservoir material shall be fabricated from stainless steel. 3.7.2 High pressure DDD. A high pressure, hand operated, double acting pump shall be installed in the system to pump hydraulic fluid from reservoir to service line. This pump shall be in accordance with Class 3000 of
20、MLP-5515 and AN6248, maximum pressure 3,000 psi. 3.7.3 Low pressure pm. A low pressure, hand operated double acting pump shall be installed in the system to pump hydraulic fluid from the reservoir to service line. The pump shall be capable of delivering a minimum capacity of 2 gallons per 30-35 stro
21、kes (complete cycles). The mechanical advantage of this pump shall be such that a maximum force of 30 pounds on the pump handle (17-20 inches in length measured from the center of the pump shaft to end of the handle) shall produce the rated flow, maximum pressure 100 psi. 3.7.4 Relief valves. Pressu
22、re relief valves shall be incorporated in the unit to protect the hydraulic system of the aircraft being serviced and the filler unit. When open, the relief valves shall pass the hydraulic fluid back to the reservoir. The pressure in the low pressure system shall not exceed 100 psi and the pressure
23、in the high pressure system shall not exceed 3300 psi. The low pressure relief valve shall be adjustable in a range of from 50 psi, or less, to 100 psi. The high pressure relief valve shall be adjustable in a range of from 100 to 3,000 psi. Each relief valve shall have a minimum proof pressure ratin
24、g of 1.5 times the maximum pressure setting. 3.7.5 Check valves. A check valve or equivalent assembly shall be used to protect the low pressure system while high pressure system is in use. 3.7.6 Filter assembly. A minimum three micron filter shall be installed between pumps and service hose. 3.7.7 P
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF83766B1997FILLERANDPRESSURIZATIONUNITHYDRAULICSYSTEM 液压 系统 填料 加压 机组 PDF

链接地址:http://www.mydoc123.com/p-428282.html