AIR FORCE MIL-PRF-25962 F-2013 VALVE LIQUID OXYGEN DRAIN.pdf
《AIR FORCE MIL-PRF-25962 F-2013 VALVE LIQUID OXYGEN DRAIN.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-PRF-25962 F-2013 VALVE LIQUID OXYGEN DRAIN.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 4820 MIL-PRF-25962F 19 December 2013 SUPERSEDING MIL-PRF-25962E 15 January 2008 PERFORMANCE SPECIFICATION VALVE, LIQUID OXYGEN DRAIN This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one typ
2、e of valve for draining 70 and 300 pounds per square inch gage (psig) liquid oxygen converters. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of thi
3、s specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of these lists, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether o
4、r not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicit
5、ation or contract. INCH-POUND Comments, suggestions, or questions on this document should be addressed to Oklahoma City Air Logistics Center/ENSDAA, 3001 Staff Drive, Suite 1AB81A, Tinker AFB, OK 73145 or emailed to tinker.dsptinker.af.mil. Since contact information can change, you may want to verif
6、y the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25962F 2 FEDERAL SPECIFICATIONS BB-A-1034 - Compressed Air, Breathing (For guidance only) CO
7、MMERCIAL ITEM DESCRIPTIONS A-A-59503 - Nitrogen, Technical (Copies of these documents are available online at http:/quicksearch.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following docu
8、ments form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASME INTERNATIONAL ASME B1.20.1 - Pipe Threads, (Inch) General Purpose (ASME documents may be obtained online at http:/www.asm
9、e.org/ or from ASME International, Three Park Avenue, New York, New York 10016-5990, USA.) SAE INTERNATIONAL SAE-ARP1176 - Oxygen System and Component Cleaning and Packaging SAE-AS4396 - Tube Connection, Bulkhead Flared, Fitting End, Design Standard SAE-AS8010 - Aviators Breathing Oxygen Purity Stan
10、dard (SAE documents may be obtained online at http:/www.sae.org/ or from SAE World Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001 USA.) 2.4 Order of Precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the ref
11、erences cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. The valves furnished under this specification shall be products that are a
12、uthorized by the qualifying activity for listing on the applicable qualified products list before contract award (see 4.2 and 6.3). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25962F 3 3.2 Recycled, recovered, or environmentally preferabl
13、e materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.3 Materials. All materials sha
14、ll be suitably treated to resist corrosion due to electrolytic decomposition, salt air, and any other atmospheric condition that may be encountered during operational use or storage (see 6.4). Materials that come into contact with liquid oxygen (LOX) shall not contain hydrocarbons, shall be non-impa
15、ct sensitive and non-degradable, and shall have a brittle point below -297F. 3.4 Interface. 3.4.1 Dimensions. The valve shall conform to the dimensions in FIGURE 1 (see 4.5.1). 3.4.2 Threads. All pipe threads shall conform to ASME B1.20.1 (see 4.5.1). 3.4.3 Markings. The word “OUTLET“ and an arrow p
16、ointing in the direction of the outlet shall be stamped on the valve body. In addition, the words “OPEN“ and “CLOSED“ with an arrow pointing to these directions shall conform to FIGURE 1 (see 4.5.1). 3.4.4 Weight. The weight of the valve shall be not greater than 0.25 pounds (see 4.5.1). 3.5 Perform
17、ance. 3.5.1 General. The valve shall operate only when the handle is placed in the “OPEN“ or “CLOSED“ position, and shall not change operating conditions without handle actuation. In addition, the valve shall operate in any mounting position (see 4.5.10). 3.5.2 Flow rate. The valve flow shall be not
18、 less than 150 liters per minute (L/min) when subjected to a pressure not greater than 5 psig (see 4.5.2). 3.5.3 Outlet port leakage. The outlet port leakage shall be not greater than 0.02 L/min when pressurized to 70 psig, 300 psig, and 10 inches of water (see 4.5.3). 3.5.4 High temperature operati
19、on. The valve shall withstand a temperature not less than 260F for not less than 4 hours (see 4.5.4). 3.5.5 Low temperature operation. The valve shall withstand a temperature not greater than -65F for not less than 4 hours (see 4.5.5). 3.5.6 Vibration. The valve shall be subjected to a vibration at
20、double amplitude of 0.02 inches and a frequency changing from 10 to 50 to 10 Hz (see 4.5.6). 3.5.7 Overall leakage. The valve body shall not leak with an internal pressure of not less than 500 psig (see 4.5.7). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
21、 IHS-,-,-MIL-PRF-25962F 4 3.5.8 Reliability. The mean cycles between failures (MCBF) of the valve shall be not less than 1,000 cycles (see 4.5.8 and 6.2). 3.6 Cleanliness. All surfaces shall be free of visible particulates (50 microns and larger), free of visible fluorinated lubricants, and free of
22、hydrocarbon contamination to a level not greater than 3 milligrams per square foot (mg/ft2) (see 4.5.9 and 6.5). 3.7 Interchangeability. All parts having the same manufacturers part number shall be functionally and dimensionally interchangeable. 4. VERIFICATION 4.1 Classification of inspections. The
23、 inspection requirements specified herein are classified as follows: a. Qualification inspection (see 4.2). b. Conformance inspection (see 4.3). 4.2 Qualification inspection. If required (see 3.1 and 6.3), qualification shall be performed on four valves. The four valves shall be subjected to all the
24、 tests in 4.5. 4.3 Conformance inspection. Conformance inspection shall include the individual tests (see 4.3.1) and the sampling tests (see 4.3.2). 4.3.1 Individual tests. Each valve shall be subjected to the following tests: a. Examination (see 4.5.1). b. Cleanliness (see 4.5.9). c. Outlet port le
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF25962F2013VALVELIQUIDOXYGENDRAINPDF

链接地址:http://www.mydoc123.com/p-428181.html