AIR FORCE MIL-F-27656 C-1987 FILTER UNIT FLUID PRESSURE MXU-408 M ABSOLUTE 5 MICRON HYDRAULIC《压力MXU - 408 米 绝对过滤额定为五微米 液压式流体过滤器组》.pdf
《AIR FORCE MIL-F-27656 C-1987 FILTER UNIT FLUID PRESSURE MXU-408 M ABSOLUTE 5 MICRON HYDRAULIC《压力MXU - 408 米 绝对过滤额定为五微米 液压式流体过滤器组》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE MIL-F-27656 C-1987 FILTER UNIT FLUID PRESSURE MXU-408 M ABSOLUTE 5 MICRON HYDRAULIC《压力MXU - 408 米 绝对过滤额定为五微米 液压式流体过滤器组》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-F-27656C 43 m 7977706 0276061 1 MIL-F-Z7656C(USAF) 20 Nov 87 Superseding MIL-F-27656B(USAF) 29 November 1968 MILITARY SPECIFICATION FILTER UNIT. FLUID, PRESSURE MXU-408/M. ABSOLUTE 5 MICRON, HYDRAULIC This specification is approved for use within the Department of the Air Force and is available
2、for use by all Departments and Agencies of the Department of Defense 1. SCOPE 1.1 This specification covers a hydraulic fluid filter unit with a replaceable element for retaining particles larger than 5 microns and 96.6 percent by weight of 5 micron and smaller particles. I .2 Classification. Type I
3、: 3000 psi operating pressure, 30 gpm flow. Type II: 5000 psi operating pressure, 35 gpm flow. 1.2.1 Reference Number. Specification reference number for items described in this specification will be formulated as shown in.parzgaph 6.4. l. -. APPLICABLE DOCUMENTS 2.1 Government Document 2. l. 1 Spec
4、ifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specificat
5、ions and Standards (DODISS) and supplement thereto, cited in the solicitation. 7 SPECIFICATIONS Federal PPP-B-60 1 Box, Wood, Cleated-Plywood PPP-B-62 1 Box. Wood. Nailed and LockCorner PPP-B-63 6 Box Shipping, Fiberboard Beneficial comments (recommendations, additions. deletions) and any pertinent
6、data which may be of iuse in improving this document should be addre-ssed to:WR-ALC/MMVRG. Robins AFB. GA 31098by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NiA FSC DISTRIBUTION STATEMENT A: Approved
7、for public release; distribution is unlimited. I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-27b5bC 43 m 777770b 027bOb2 3 W Military MIL-A-8625 MIL-P-1 16 MIL-B-1 2 1 MIL-H-5606 Anodic coatings, for aluminum and aluminum alloys Preservatio
8、n, Methods of Barrier Material, Greaseproofed, Waterproofed, Flexible Hydraulic Fluid, Petroleum Base, Aircraft, Missile and Ordnance STANDARDS Military DOD-STD-1 O0 MIL-STD-129 MIL-STD-130 MIL-STD-143 Engineering Drawing Practices Marking for Shipment and Storage Identification Marking of U.S. Mili
9、tary Property Specifications and Standards, Order of Precedence for the Selection of MIL-STD-83 1 MIL-STD-889 MS3 102 MS16142 MS2439 1 MS33649 MS33656 Test Reports, Preparation of Dissimilar Metals Connector, Receptacle, Electric, Box Mounting Boss, Gasket Seal Straight Thread Tube Fitting, Standard
10、 Dimensions for (Supersedes AN8 14) Bosses, Fluid Connection - Internal Straight Thread Fitting End, Standard Dimensions for Flared Tube Connection and Gasket Seal 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form
11、a part of this specification to the extent specified herein. Unless otherwise specified, the issues shall be those in effect on the date of the solicitation. Air Force-Navy Aeronautical AN8 14 Plug and Bleeder - Screw Thread AND 10050 Bosses, Standard Dimensions for Gasket Seal Straight Thread (Copi
12、es of specifications, standards, handbooks, drawings, publications, and other Government documents required by contractors in connection with specific acquisition functions should be obtained from the Contracting activity or as directed by the contracting activity. 2.3 Order of precedence. In the ev
13、ent of a conflict between the text of this specification and the references cited herein (except for associated detail specifications, specification sheets or MS standards), the text of this specification shall take precedence. Nothing in this specification, however, shall supersede applicable laws
14、and regulations unless a specific exemption has been obtained; 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-2765bC 93 M 9999906 0276063 5 W 3. REOUIREMENTS 3.1 GENERAL 3.1.2 Components. The filter unit shall consist of the following majorc
15、components: Description See Requirement Housing 3.5.1 Element 3.5.2 Differential pressure indicator 3.5.3 3.1.3 Selection of specifications and standards. Specifications and standards for necessary commodities and services not specified herein shall be selected in accordance with MIL-STD-143. 3.2 Ma
16、terials. 3.2.1 Protective treatment. Except for filter elements, aluminum alloy parts shall be anodized in accordance with MIL-A-8625. The use of plating to meet corrosion resistance of metals referred to in paragraph 3.2.2 is prohibited. 3.2.2 Metals. Metals shall be of the non-ferrous type in orde
17、r to resist corrosion due to water, hydraulic fluids, salt spray, or atmospheric conditions likely to be met in storage or normal service. 3.2.3 Dissimilar metals. Unless protected against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other. Dissimilar met
18、als are defined in MIL-STD-33586. 3.2.4 Recovered materials. For the purpose of this requirement, recovered materials are those materials which have been collected from solid waste and reprocessed to become a source of raw materials, as distinguished from virgin raw materials. The components, pieces
19、 and parts incorporated in the filter unit may be newly fabricated from recovered materials to the maximum extent practicable, provided the filter unit produced meets all other requirements of thisspecification. Used, rebuilt or remanufactured com- ponents, pieces and parts shall not be incorporated
20、 in the filter unit, 3.3 Design and construction. The filter unit shall be designed and constructed so that no parts will work loose in service. The filter mit shall withstand the stresses, jars, vibrations, and other conditions incident to shipping, storage, installation, and flight line service. 3
21、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. MIL-F-27bSbC 43 m 7777706 0276064 7 m MIL-F-:!7656C(USAF) 3.3.1 Functional design. The filter unit shall be designed as a light weight filter for use with hydraulic fluids conforming to MIL-H-5606 wi
22、th flow rates and operating pressures per paragraph 1.2. 3.3. Reliability. The filter unit shall be designed and constructed as specified herein and to successfully complete the tests in paragraph 4.4.3 with no failures preventing satisfactory performance. 3.3.3 Maintainability. The filter unit shal
23、l be designed and constructed as specified herein and to pro- vide the following: a. Minimum number of parts consistent with the reliability and performance specified herein. b. Minimum amount of training and time necessary for assembly, disassembly, location of trouble sources, and maintenance incl
24、uding servicing. c. Permit maintenance with general-purpose tools and equipment normally available com- mercially. Use of special-purpose tools and equipment shall be subject to procuring activity approval. d. Permit adjustments, servicing, replacement of parts and components, and other maintenance
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILF27656C1987FILTERUNITFLUIDPRESSUREMXU408MABSOLUTE5MICRONHYDRAULIC 压力 MXU408 绝对 过滤 额定 微米 液压式

链接地址:http://www.mydoc123.com/p-427788.html