1、MIL-DTL-25666/5 (USAF) 15 September 1995 SUPERSEDING 20 September 1978 MIL-C-27336B (USAF) DETAIL SPECIFICATION CONVERTER, LIQUID OXYGEN TYPE GCU- 17/A This specification is approved for use by the Department of the Air Force and is available for use by all Departments and Agencies of the Department
2、 of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of liquid oxygen converter with a capacitance gauging element. It provides storage and pressurization of 25 liters of liquid oxygen to 300 pounds per square inch gauge Sig), nominal pressure and does not include warming coils. The c
3、onverter is designated type GCU-l7/A. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are needed to meet the requirements specified in sections 3, 4, and 5 of this specification. This section does not include documents cited in other sections of this specification or recomm
4、ended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3,4, and 5 of this specification, whether or not they are listed. 2.2 Gov
5、ernment documents. 2.2.1 SDecifications. and standar ds. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these docunients are those listed in the issue Of the Department of Defense Index for Specificati
6、ons and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-V-9050 MIL-(2-255 16 MIL-DTL-25666 Valve, Oxygen, Pressure Relief, Aircraft Connectors, Electrical , Miniature, Coaxial, Environment Resistant Type, Converter, Liquid Oxyg
7、en, Capacitance Type Gauging, General Specification General Specification for For Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use improving this document should be addressed to: OC-ALCRICLA, 300 1 Staff Drive, Tinker AFB, OK 73 145- 5990 by usin
8、g the Standardization Document Improvement Proposal D Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 1660 PISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without licens
9、e from IHS-,-,- - HIL-DTL-25686/5 m 9999906 2005832 658 m MIL-DTL-25666/5 STANDARD DEPARTMENT OF DEFENSE MIL-STD-129 Marking for Shipment and Storage (Unless otherwise indicated, copies of federal and military specifications, and standards are available fiom the Standardization Documents Order Desk,
10、 Building 4D, 700 Robbins Ave, Philadelphia, PA 191 11-5094) 2.3 Orde r of Precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this documents takes precedence. Nothing in this document, however, supersedes applicable laws and regulati
11、ons unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Oualification. Converters furnished under this specification shall be products which are qualified for listing on the applicable qualified products list at the time set for opening of bids (see 4.2 and 6.3). 3.2 Desi-. The conver
12、ter shall conform to the dimensions and general design as shown on figures I and 2. The converter shall have a minimum capacity of 25 liters of liquid oxygen measured at 1 atmosphere plus at least 3 percent of this volume to allow for the change in liquid density at the operating pressure. The conve
13、rter shall be designed for an operating pressure of 300 psig. The converter shall be integrally shock mounted so that the entire converter assembly, including ports, is isolated fiom the mounting base. The natural resonant frequency of the vibration isolators shall fall between 8 and 30 cycles per s
14、econd (cps). No resonance of the converter shall occur at a frequency less than 40 cps. The bosses for all pipe thread ports shall be fabricated fiom corrosion-resistant steel. 3.2.1 Schematic diamam. The converter shall be designed in accordance with the schematic diagram as shown on figure 3. 3.2.
15、2 Desim strenh. The converter shall be designed to satis the dynamic force requirements specified in MIL-DTL-25666. When subjected to the acceleration test, the following exceptions to the values for G levels shall apply. Vertical (down) 9G Vertical (up) 3G Lateral 4G 3.2.3 Relief valves. The relief
16、 valves shall conform to the performance requirements of types III and IV of MIL-V-9050 and shall be of such size and shape to fit the overall dimensions specified for the converter. 3.2.4 Weight. The weight of the complete converter shall not exceed 40 pounds. 3.2.5 Markine of orts. Ports shall be
17、marked as shown on figure 2. 3.2.6 Overpressure safety device. Safely discs or other secondary overpressure devices, as specified in 3.6.6 of MIL-DTL-25666 shall not be required for this converter. The design of this converter incorporates two pressure relief valves, in accordance with MIL-DTL-25666
18、. 3.3 Performance. 3.3.1 -. The pressure used for the Final Assembly Pressure test shall be 320 psig. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 il IL- D T L- 25 b b b ! 5 999990b 2005833 594 MIL-DTL-25666/5 b 3.3.2 Fillin? time. Filling tim
19、e shall not exceed 10 minutes when the converter is tested as specified in MIL- DTL-25666. 3.3.3 Evaporation los. 3.3.3.1 Vent condition. The evaporation loss of the essentially full converter in the vent condition shall not exceed 4 pounds of oxygen when tested as specified in MIL-DTL-25666. 3.3.3.
20、2 Buildup condition. The evaporation loss of the essentially full converter in the buildup condition shall not exceed 4 pounds of oxygen when tested as specified in MIL-DTL-25666. 3.3.4 BuilduD time. Buildup time shall not exceed 10 minutes when the converter is tested as specified in MIL-DTL-25666.
21、 3.3.5 Cayacitance. The capacitance of the sensing element of the empty converter shall be 303.5 k2.5 picofarads (pf). 3.3.6 Inner vessel pressure. 3.3.6.1 Innervessel. The inner vessel shall meet the performance requirements for the inner vessel pressure test specified in MIL-DTL-25666 when subject
22、ed to a pressure of 500 psig. 3.3.6.2 Permanent volumetric expansion. The converter shall meet the performance requirements for permanent volumetric expansion as specified in MIL-DTL-25666 when subjected to a pneumatic or hydrostatic pressure of 500 psig. 3 3.7 Delivery rate. 3.3.7.1 Constant flow.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILDTL2566651995CONVERTERLIQUIDOXYGENGCU17AGCU17A 液氧 转换器 PDF

链接地址:http://www.mydoc123.com/p-427714.html