《AIR FORCE A-A-58050 A-2000 FLUORESCENT PENETRANT INSPECTION UNITS INTEGRALLY ASSEMBLED SINGLE UNIT AND SEPARATE MODULAR STATION TYPES《单一部件和个别标准化装置类型部件完整装配荧光渗透剂检验》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-58050 A-2000 FLUORESCENT PENETRANT INSPECTION UNITS INTEGRALLY ASSEMBLED SINGLE UNIT AND SEPARATE MODULAR STATION TYPES《单一部件和个别标准化装置类型部件完整装配荧光渗透剂检验》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUND - UA O8 November 2000 SUPERSEDING 20 October 1995 A-A-5 8050 COMMERCIAL ITEM DESCRIPTION FLUORESCENT PENETRANT INSPECTION UNITS INTEGRALLY ASSEMBLED SINGLE UNi AND SEPARATE MODULAR STATION TYPES The General Services Administration has authonzed the use of this commercial item description
2、as a replacement for MIL-F-38762 (USAF) for all federal agencies. 1. SCOPE. This commercial item description covers fluorescent penetrant inspection units using the post-emulsification penetrant method. 2. CLASSIFICATION. This commercial item description covers three different types and six sizes of
3、 Fluorescent Penetrant Inspection Units, hereafter referred to as “unit or units.“ Note: The length dimension is left to right. while the width dimension is front to rear. 2.1 Types. The units shall conform to the following types: Type I - Integrally assembled single unit (Applicable only to Size i)
4、 Type II - Separate modular stations (Applicable to Size 2 - 6) 2.2 Sizes. The units shall conform to the following sizes: Size Designation Frame Sizes Tank Sizes 1 PT-18 2 PT-24 3 PT-36 4 PT48S (Short) 5 PT-48 6 PT-72 102“ long x 34“ wide x 36“ tall 24“ long x 34“ wide x 36“ tall 36“ long x 34“ wid
5、e x 36“ tall 48“ long x 34“ wide x 36“ tall 48“ long x 34“ wide x 36“ tall 72“ long x 50“ wide x 36“ tall 17“ long x 29“ wide x 14“ deep 22“ long x 29“ wide x 20“ deep 33“ long x 29“ wide x 26“ deep 43“ long x 29“ wide x 26“ deep 43“ long x 29“ wide x 26 deep 67“ long x 44“ wide x 26 deep Beneficial
6、 comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Oklahoma City Air Logistics Center, 300 1 Staff Drive, Tinker AFB, OK 73 145-5990. I I AMSC N/A FSC 6635 Provided by IHSNot for ResaleNo reproduction or networking pe
7、rmitted without license from IHS-,-,-A-A-58050A 3. SALIENT CHARACTERISTICS. 3.1 First Article Testing. When specified a sample shall be subjected to first article inspection (see 5.2 and 7.5g.) 3.2 Design and Construction. The units shall be designed and constructed to facilitate efficient inspectio
8、n of parts and assemblies capable of being penetrant inspected. They shall be constructed to hold aircraft parts and inspection materials without deformation of the components. The units shall be designed and constructed so that dunng the normal inspection process there will be no leakage of penetra
9、nt, remover, developer, and/or water within the area bounded by the outermost extremities of the inspection unit; nor shall they leak from station to station, except for drain stations back to their respective reservoirs. 3.3 Tolerances. All tolerances for dimensional specifications for tank and fra
10、me sizes listed in this comercial item description are f 0.5 inch unless otherwise noted. 3.4 Stations. These inspection units, except Type I, shall consist of the following stations: penetrant tank, penetrant drain, pre-rinse, remover, remover-rinse, developer, developer drain, dryer, rest, and ins
11、pection stations. All stations shall be a modular design to enable customization of installation with end-user procured accessories, such as 90 degree roller stations. Type I shall consist of a penctrant tank, remover tank, rinse tank, developer tank, dryer, and inspection station, integrally assemb
12、led in one unit. 3.4.1 Penetrant, Remover, and Developer Stations. These stations shall consist of a kame, tank, cover, and for Type II a slatted grille made from open (Le. I, C, or hat section) aluminum extnisions. A drain connection and cutoff valve shall be provided at the bottom of the tanks usi
13、ng standard pipe sizes ( .5 inch for Size 1 increasing to 1.25 inch for Size 6) 3.4.1.1 Station Dimensions. The usable area inside the tank shall conform to the tank sizes listed in paragraph 2.2. The frame shall have overall outside dimensions not to exceed the frame dimensions listed in paragraph
14、2.2; height will exclude cover and cover handle. All tanks and covers shall be made of 16 gauge stainless steel. Type 304 stainless steel shall be used unless otherwise specified. 3.4.1.2 Type II Penetrant Station. The Type II station shall be equipped with an air-driven pump, with flow-on swivel no
15、zzle i.e. there shali be no canopy support post(s) in front of the station. A standard drain pipe connection and cutoff valve shall be provided at the bottom of the tanks. The length of station shall be 48“ for Sizes 2 - 5, and 72“ for Size 6. 3.4.3.1 Canopy. The remover-rinse station requires a fll
16、 canopy with side curtains, split to allow ingress and egrexugh the station. The curtain material shall be weather resistant, waterproof cloth meeting the intent of MIL-PW-20696, Type II, Class 2. The canopy shall provide a split top to allow access fi-om an overhead conveyor. The curtain material s
17、hall be attached to the canopy with snaps, or hook & pile fasteners, for easy removal and replacement. The canopy shall not allow more than 20 lux of light from the outside. 3.4.4 Penetrant and Developer Drain Stations. All drain stations shall consist of a frame, drain pan, and a full roller top gr
18、ille. The drain stations shall be structurally supported from below. Each station will conform to the requirements of paragraph 4.3.6. Design shall be such to insure that the penetrant or developer is completely directed back into its tank. The drain pan shall prevent fluids from running off inspect
19、ed materials and dripping on the floor. The total length and width of the rollcr top grille shall conform to the length and width of the station and conform to the height of adjacent stations, However, the roller top grill shall be made in sections of 24 inches or less to facilitate easy removal for
20、 cleaning of the drip pan. The length of the Type II Size 4 drain stations shall be 24 inches to reduce total system length. 3.4.5 Dryer Station. The dryer station shall incorporate a full roller grille to facilitate the movement of parts from the developer drain station to thc rest station. The dry
21、er cabinet shall be designed with a split roof to allow access from an overhead conveyor with both ends opened. (Not applicable to Type I units.) Insulation of the dryer to conserve energy is highly desirable. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
22、m IHS-,-,-A-A-58050A Type - Size - I II - 3 - - - 3.4.5.1 Split curtains shall be provided for each end. The curtain material shall be attached to the dryer ends with snaps, or hook & pile fasteners, for easy removal and replacement. A curtain shall be provided for the split roof when the overhead c
23、onveyer is not used. The curtain shall be attached to the dryer roof with sewn-in magnets. The curtain material shall be weather resistant, waterproof cloth meeting the intent of MIL-PRF-20696, Type II, Class 2. However, an insulating or reflective coating on the inside of the curtains to conserve e
24、nergy is highly desirable. Exterior Dimension interior Dimension Curtain Uimension Wattage (minimum) 18“ L x 34“ w x 18“T 1“L x 30“ w x 16“T 24“ L x 34“ w x 24“T 22“L x 30“W x 22“ 1 36“ L- 34“ L x 30“ W x 30“ T 48“ L x 34“ w x36“T 46“L x 30“ w x 30“ T 12 L x 34“ . w x 36“ 1 10“ L x 30“ w x 30“ 1 96“
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA58050A2000FLUORESCENTPENETRANTINSPECTIONUNITSINTEGRALLYASSEMBLEDSINGLEUNITANDSEPARATEMODULARSTATIONTYPES

链接地址:http://www.mydoc123.com/p-426961.html