1、A-A-58037 M 9999974 0365530 174 I INCH-POUND 1 I I A-A-58037 October 28, 1994 COMMERCUL ITEM DESCRIPTION GENERA TOR, PULSE The General Services Administration has authorized the use of this Commercial Item Description ( CID ) for all agencies. 1. SCOPE This CID, describes a pulse generator with a de
2、lay range fiom O to 99.99 milliseconds. This CID is meant as a minimum requirement for the pulse generator in which only those manufacturers that meet or surpass the following requirements are qualified per this CID. 2. CLASSIFICATION Equipment covered by this CID may be commercially available equip
3、ment modified to the extent necessary to meet the following description. The equipment shall be Type III, Class 5, Style E and Color R in accordance with MIL-T-28800. 3. SALIENT CHARACTERISTICS 3.1 Design and construction. The equipment shall be UL (Underwriters Laboratories) listed and approved and
4、or shall comply with the Type III safety requirements of MIL-T-28800. 3.2 Electrical power sources . The equipment shall operate from nominal commercial, military and shipboard power sources of 115/230 volts AC (*lo%) at line frequencies of 50 to 60 Hz. Transient state conditions shall meet MIL-T-28
5、800 Class 5 requirements. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: The Resources and Logistics Services Division, SA-ALCITILDD, Bldg. 171, Post C-12,485 Quentin Roosevelt Rd., Kelly AFB, TX 78241
6、 -6524. AMSC N/A FSC 6625 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58037 W 9999974 0365533 O00 W A-A-58037 3.3 Temperature requirements. (a) Operating temper
7、ature. The equipment shall meet its performance and accuracy requirements in an operating environment of +5“c to +55“c. (b) Non-operating temperature. The equipment shall meet its performance and accuracy requirements in a non-operating environment of 0C to +60C. 3.4 Mean time between failures (MTBF
8、). The equipment MTBF shall be 2,000 hours. The lower test MTBF shall be 2,000 hours and the upper test MTBF shall be 4,000 hours. 3.5 Pre-conditioning requirement. Each deliverable equipment shall be capable of being subjected to the environmental screening effects of burn-in and thermal cycling, w
9、ith thermal cycling being accomplished in the sample testing phase. 3.6 Calibration and maintenance adjustments. The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustments. These adjustments shall be provided by variable value components which a
10、re adjustable by the use of simple means. The calibration by substitution of selected components or parts is unacceptable unless specifically approved. The calibration adjustments, wherever possible, shall be accessible without removal of the instrument case or modules. The calibration interval shal
11、l be a period of one year or greater based on an operating time of 2,000 hours. 3.7 Performance characteristics. (a)Pulse delay (1)Delav range. The delay range of the generator shall be from O to 99.99 milliseconds (ms), selectable in 1 nanoseconds (ns) increments. (2)Delay accuracy. The minimum del
12、ay accuracy shall be k (1 ns + time setting x time base stability). (b)Pulse width (1)Pulse width rance. The pulse width range of the generator shall be from 5 to 9.99 ms, selectable in 1 nanoseconds increments. (2)Pulse width accu racy. The minimum pulse width accuracy shall be I1 ns plus time base
13、 stability). (c)Time base stability (1)Long term. The long term stability shall be better than 3xiO-/day 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58037 (2)Temperature. The temperature stability shall be better than 1x1 O-*OC. (d)Inserion
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA580371994GENERATORPULSE 发电机 脉冲 PDF

链接地址:http://www.mydoc123.com/p-426941.html