AIR FORCE A-A-58035-1994 GENERATOR SIGNAL 2.0 TO 8.4 GHZ《2.0至8.4吉赫信号发生器》.pdf
《AIR FORCE A-A-58035-1994 GENERATOR SIGNAL 2.0 TO 8.4 GHZ《2.0至8.4吉赫信号发生器》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-58035-1994 GENERATOR SIGNAL 2.0 TO 8.4 GHZ《2.0至8.4吉赫信号发生器》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、I INCH POUND I A-A-58035 October 17, 1994 COMMERCIAL ITEM DESCRIPTION GENERA TOR, SZGNM 2.0 TO 8.4 GHZ The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies. This CID describes a synthesized signal generator which operates from
2、2.0 GHz to 8.4 GHz and has AM, FM and pulse modulation capabilities. This is a general purpose signal generator. This CID is meant as a minimum requirement for the synthesized signal generator in which only those manufacturers that meet or surpass the following requirements are qualified per this CI
3、D. 2.1 Desien and Construct io& The equipment shall comply with the type III safety and environmental requirements of MIL-T-28800. The equipment shall also meet the following paragraphs on MIL-T-28800: 3.6.3 Enclosure form, Style C 3.7.4.1 Vibration, sinusoidal 3.8.3 EMI, Type III 3.9.3.1 Accessible
4、 Potentials, Type III 3.9.3.1.2 Leakage Current Protection, Type III Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: The Resources and Logistics Services Division, SA-ALCTILDD, Bldg. 17 1, Post C-12,485
5、 Quentin Roosevelt Rd., Kelly AFB TX 78241-6524. AMSC NIA FSC 6625 DISTRIRUTION STATE MENT A, Approved for public release, distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A- A-58035 2.2 Electrical Power Sources . The equipm
6、ent shall operate from nominal commercial, military and shipboard power sources of 100, 110, 120,200,220,240 volts AC (*lo%) at line frequencies of 50 Hz to 400 Hz. Power consumption shall not exceed 300 watts. Transient state conditions shall meet MIL-T-28800 requirements for the classification spe
7、cified herein. 2.3 man time between failu res (MTB FI, The equipment MTBF shall be 2,000 hours. The lower test MTBF shall be 2,000 hours and the upper test MTBF shall be 4,000 hours. . 2.4 Pre-conditiowp reauiremea Each deliverable equipment shall be capable of being subjected to the environmental s
8、creening effects of burn in and thermal cycling, with thermal cycling being accomplished in the sample testing phase. 2.5 Calibration and -ce adiustments, The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustments. These adjustments shall be pro
9、vided by variable value components which are adjustable by the use of simple means. The calibration by substitution of selected components or parts is unacceptable unless specifically approved. The calibration adjustments, wherever possible, shall be accessible without removal of the instrument case
10、 or modules. The calibration interval shall be a period of one year or greater based on an operating time of 2,000 hours. 2.6 Performance charactenstics, The performance characteristics as described below shall constitute minimum Air Force requirement of this item and shall be adhered to or surpasse
11、d in quality and function. (a) Frequency, The minimum frequency range shall be 2 GHz to 8.4 GHz. (1) Frequency accuracy shall be the same as internal time base. (2) Internal time base stability shall be a minimum of 4 x 10-7 per day. (3) External time base input shall override the internal time base
12、 and accept a 10 MHz frequency with a level or 0.5 V RMS. Stability shall be better than 1 x 10-7. (b) SpecPuntv. The spectral purity of the signal generator shall meet or exceed the specifications as follows: (1) Single-sideband phase noise shall be less than -70 dBc in a 1 Hz bandwidth, 1 KHz offs
13、et from the carrier in the CW mode. (2) Harmonics shall be less than -40 dBc at the +8 dBm output. (3) Sub Harmonics shall be less than -35 dBc at the +8 dBm output. (4) Spurious signals which are non-harmonic or power line related shall be less than -55 dBc for all carrier frequencies and shall be
14、measured 15 KHz away from the carrier. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-58035 D 9999974 O365503 346 = A-A-58035 (5) Power line related signals related to power line frequencies or any other internal mechanical or electrical devic
15、es shall be less than -45 dBc for any signal within +20 KHz from the fundamental frequency. (6) Residual AM shall be less than -50 dBc in a 300 Hz to 3 KHz post detection bandwidth. (7) Residual FM shall be less than 25 Hz RMS in a 300 Hz to 3 KHz post- detection bandwidth. (cl Resolut ion, The reso
16、lution shall be 1 KHz to 6.6 GHz and 2 KHz to 8.4 GHz. (4 Power OUtUt, The power output level shall be adjustable from +8 dBm to -120 dBm over the entire operating temperature range into a 50 ohm load with a standing wave ratio of 2.5 or less. The output shall have a flatness of +2 dB at 3 dBm outpu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA580351994GENERATORSIGNAL20TO84GHZ20 84 信号发生器 PDF

链接地址:http://www.mydoc123.com/p-426937.html