1、 AMSC N/A FSC 6635 DISTRIBUTION STATEMENT A. Approved for public release: distribution is unlimited. Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data that may improve this document should be sent to WR-ALC/403 SCMS, 460 Richard Ray Blvd, Suite 200,
2、Robins AFB, GA 31098-1813. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil . A-A- 59874A 26 June 2012 A-A- 59874 30 JULY 2010 COMMERCIAL ITEM DESCRIPTION HYDROGEN LEAK DETECTOR The General
3、 Services Administration has authorized the use of this commercial item description (CID), for all federal agencies. 1. SCOPE. This CID describes a portable hydrogen leak detector, which is used to determine the location of leaks in fuel tanks as well as other aircraft systems. By filling a fuel tan
4、k or container with hydrogen (the hydrogen acts as a tracer and is in a maximum concentration of 5% with 95% nitrogen), the hydrogen leak detector will enable aircraft maintainers to locate the origination point(s) of the leak(s) as the hydrogen escapes into the atmosphere. 2. SALIENT CHARACTERISTIC
5、S. 2.1 Hydrogen leak detector description. The hydrogen leak detector shall be supplied with a hydrogen leak detector unit, a probe with cable and associated connectors, battery charger, calibrated reference leak, and electrical cable to use 110VAC 50/60 Hz. 2.2 Design and construction. The hydrogen
6、 leak detector shall be designed and constructed so that no parts will work loose in service. They shall be built to withstand the strains, jars, vibrations, and other conditions incident to shipping, storage, installation, and service. They shall be weatherproof and designed to prevent the intrusio
7、n of water and sand into critical operating components. The detector shall display leak rates in units of parts per million (ppm). 2.2.1 Electromagnetic interference (EMI). The hydrogen leak detector shall be in accordance with the following radiated emission and susceptibility requirements of MIL-S
8、TD-461: RE102 and RS103. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59874A 2 2.2.2 Electrostatic discharge. The design of the hydrogen leak detector shall preclude equipment damage due to electrostatic discharge (ESD), protect per
9、sonnel from electrical shock due to static charging, and prevent ignition of explosive atmospheres due to sparking. 2.2.3 Human engineering. The hydrogen leak detector shall be designed in accordance with MIL-STD-1472 for ease of operation, inspection, and maintenance, including the use of arctic mi
10、ttens and Mission-Oriented Protective Posture (MOPP) Level 4 Chemical Warfare Gear. 2.3 Environmental conditions. 2.3.1 Operating temperature range. The hydrogen leak detector shall be capable of operating in ambient temperatures ranging from 0C to 50C. 2.3.2 Operating conditions. The hydrogen leak
11、detector shall be authorized for operation in a Class I, Division 1 environment where ignitable concentrations of flammable gases, vapors, or liquids are present within the atmosphere under normal operational conditions in accordance with UL 913, UL 1203, NFPA 496, and UL 60079-11. 2.3.3 Certificate
12、 of conformance2.4 Performance. . The hydrogen leak detector shall be supplied with a certificate of conformance certifying compliance with UL 913 Class I, Division 1 requirements. 2.4.1 Concentration. The minimum hydrogen detectable concentration required shall be 0.5 parts per million. 2.4.2 Calib
13、ration. The hydrogen leak detector shall have an internal calibration function that can be performed by the field users. 2.5 Standard probe. The detector shall be supplied with a handheld replaceable hydrogen detecting probe with cable and associated connectors. 2.6 Input voltage source. The leak de
14、tector shall operate at 110 or 220 VAC, 50 to 60 Hz, as well as 12 volt direct current (VDC) at 770 milliamps using a rechargeable lithium ion battery or equivalent. 2.7 Batteries. At least one commercially available lithium ion battery (or equivalent) shall be supplied as the power source for detec
15、tor operation. The hydrogen leak detector shall have a run time of at least 5 hours before having to re-charge the battery. 2.7.1 Battery charger. The hydrogen leak detector shall be supplied with a battery charger to charge its battery to a fully charged state in less than 12 hours. A fully charged
16、 state is defined as 12.6 volts and 770 milliamps. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59874A 3 2.8 Foreign power requirements. When foreign power sources are utilized due to the leak detectors being operated at foreign destinations,
17、proper electrical plugs/adapters and transformers shall be provided to allow the leak detector unit and leak detector battery charger to operate properly. 2.9 Operating conditions. 2.9.1 Relative humidity. The hydrogen leak detector shall be capable of operating at a maximum relative humidity of 90%
18、. 2.10 Detector dimensions. The dimensions of the hydrogen leak detector shall not exceed 5.25in x 9.5in x 6.75in. 2.11 Detector weight. The hydrogen leak detector shall not weigh more than eleven pounds including the battery. 2.12 Storage/carrying case. The hydrogen leak detector shall be supplied
19、with a storage/carrying case capable of storing the detector and all related components including the operation manual. 2.13 Workmanship. The hydrogen leak detector, including all parts and accessories, shall be constructed and finished in a thoroughly workmanlike manner. Workmanship objectives shal
20、l include freedom from blemishes, defects, burrs and sharp corners and edges; accuracy of dimensions, surface finish, and radii of fillets; thoroughness of welding, painting, and riveting; marking of parts and assemblies; and proper alignment of parts and tightness of assembly fasteners. 2.13.1 Bolt
21、ed connections. Bolt holes shall be accurately punched or drilled and shall be deburred. Threaded fasteners shall be tight and shall not work loose during testing or service usage. 2.13.2 Riveted connections. Rivet holes shall be accurately punched or drilled and shall be deburred. Rivets shall be d
22、riven with pressure tools and shall completely fill the holes. Rivet heads shall be full, neatly made, concentric with the rivet holes, and in full contact with the surface of the component. 3.0 REGULTORY REQUIREMENTS 3.1 Recycled, recovered, or environmentally preferable materials. Recycled, recove
23、red, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. The offeror/contractor is encouraged to use recovered material
24、s to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59874A 4 3.2 Green Procurement Program. Green Procurement Program (GPP) is a man
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA59874A2012HYDROGENLEAKDETECTORPDF

链接地址:http://www.mydoc123.com/p-426836.html