AHRI 761 SI-2014 Performance Rating of Solenoid Valves for Use with Volatile Refrigerants.pdf
《AHRI 761 SI-2014 Performance Rating of Solenoid Valves for Use with Volatile Refrigerants.pdf》由会员分享,可在线阅读,更多相关《AHRI 761 SI-2014 Performance Rating of Solenoid Valves for Use with Volatile Refrigerants.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 2014 Standard for Performance Rating of Solenoid Valves for Use with Volatile Refrigerants Approved by ANSI on May 15, 2015 ANSI/AHRI Standard 761 (SI) Price $10.00 (M) $20.00 (NM) Copyright 2014, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States P
2、atent and Trademark Office Note: This standard supersedes AHRI Standard 760-2007. For I-P ratings, see ANSI/AHRI Standard 760 (I-P)-2014. IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, teste
3、d, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this st
4、andard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under the standards/guidelines will not be non-hazardous or free from risk. TABLE OF CONTENTS SECTION P
5、AGE Section 1. Purpose 1 Section 2. Scope .1 Section 3. Definitions .1 Section 4. Test Requirements .2 Section 5. Rating Requirements .2 Section 6. Minimum Data Requirements for Published Ratings 4 Section 7. Marking and Nameplate Data 4 Section 8. Conformance Conditions .4 TABLES Table 1. Standard
6、Rating Conditions .2 Table 2. Published Application Ratings for Discharge Gas Service .4 APPENDICES Appendix A. References - Normative .5 Appendix B. References - Informative .5 Appendix C. Method of Testing for Rating Solenoid Valves for Maximum Operating Pressure Differential (MOPD) - Normative 6
7、Appendix D. Recommended Standard Connection Sizes - Informative .13 TABLES FOR APPENDICES Table C1. Pressure-tap Hole Diameters and Lengths 8 Table D1. Recommended Standard Connection Sizes .13 FIGURES FOR APPENDICES Figure C1. Typical System Piping for Solenoid Valve MOPD Test with Gas or Liquid .7
8、 Figure C2. Typical Electrical Test Apparatus for an Alternating Current Solenoid Valve .9 Figure C3. Typical Electrical Test Apparatus for a Direct Current Solenoid Valve .10 _ANSI/AHRI STANDARD 761 (SI)-2014 1 PERFORMANCE RATING OF SOLENOID VALVES FOR USE WITH VOLATILE REFRIGERANTS Section 1. Purp
9、ose 1.1 Purpose. The purpose of this standard is to establish for Solenoid Valves for use with volatile refrigerants: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This stand
10、ard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Solenoid Valves for use w
11、ith volatile refrigerants as defined in Section 3. Section 3. Definitions All terms in this document follow the standard industry definitions in the ASHRAE Terminology website (https:/www.ashrae.org/resources-publications/free-resources/ashrae-terminology) unless otherwise defined in this section. 3
12、.1 Bubble Point. Refrigerant liquid saturation temperature at a specified pressure. 3.2 Dew Point. Refrigerant vapor saturation temperature at a specified pressure. 3.3 Main. Tubing or piping by which the Solenoid Valve is connected to the apparatus. 3.4 Maximum Operating Pressure Differential (MOPD
13、). The maximum pressure difference between the solenoid valve inlet and the solenoid valve outlet at which the Solenoid Valve will operate, kPa. 3.5 Pressure Drop. The pressure difference between the solenoid valve inlet and the solenoid valve outlet with the main port (orifice) open, kPa. 3.6 Publi
14、shed Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Publi
15、shed Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.6.1 Application Rating. A rating based on tests performed at application Rating Conditio
16、ns (other than Standard Rating Conditions). 3.6.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.7 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.7.1
17、 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. ANSI/AHRI STANDARD 761 (SI)-2014_ 2 3.8 “Shall“ or “Should.“ “Shall“ or “should“ shall be interpreted as follows: 3.8.1 Shall. Where “shall“ or “shall not“ is used for a provision specifie
18、d, that provision is mandatory if compliance with the standard is claimed. 3.8.2 Should. “Should“ is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.9 Solenoid Valve. A valve which is actuated by the magnetic action of an electrically energized coil. T
19、he opposite action is accomplished by gravity, pressure or spring action. 3.9.1 Direct-action Solenoid Valve. A valve in which the magnetic power of an electrically energized coil moves the main port (orifice) closure member. 3.9.2 Normally Closed Solenoid Valve. A valve which is closed when de-ener
20、gized. When the coil is electrically energized, the closure member is moved away from and off the port (orifice) to cause the opening action. 3.9.3 Normally Open Solenoid Valve. A valve which is open when de-energized. When the coil is electrically energized, the closure member is moved toward and o
21、nto the port (orifice) to cause the closing action. 3.9.4 Pilot-operated Solenoid Valve. A valve in which the motion of a direct-acting member allows a pressure difference to occur across the main port (orifice) closure member, causing it to move. 3.10 Solenoid Valve Capacity. The mass flow rate of
22、a fluid through the Solenoid Valve, equated to tons of refrigeration, kW, at the specified conditions. 3.11 Volatile Refrigerant. A refrigerant that changes from the liquid to the vapor state in the process of absorbing heat. Section 4. Test Requirements 4.1 Capacity Tests. All capacity tests shall
23、be in accordance with the test procedure defined in ANSI/ASHRAE Standard 158.1. 4.2 MOPD Tests. All MOPD tests shall be in accordance with the test procedure in Appendix C. 4.2.1 If the Solenoid Valve MOPD depends on the valve position, the valve shall be tested in all positions for which the rating
24、s apply. Section 5. Rating Requirements 5.1 Rating Requirements. Published capacity ratings shall consist of Standard Ratings and may include Application Ratings. The AHRI Standard Ratings of Solenoid Valve Capacity for Volatile Refrigerants shall be stated in tons of refrigeration and at the condit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI761SI2014PERFORMANCERATINGOFSOLENOIDVALVESFORUSEWITHVOLATILEREFRIGERANTSPDF

链接地址:http://www.mydoc123.com/p-422579.html