AHRI 430 I-P-2014 Performance Rating of Central Station Air-handling Unit Supply Fans.pdf
《AHRI 430 I-P-2014 Performance Rating of Central Station Air-handling Unit Supply Fans.pdf》由会员分享,可在线阅读,更多相关《AHRI 430 I-P-2014 Performance Rating of Central Station Air-handling Unit Supply Fans.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、 2014 Standard for Performance Rating of Central Station Air-handling Unit Supply Fans AHRI Standard 430 (I-P) Price $10.00 (M) $20.00 (NM) Copyright 2014, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office Note: This stan
2、dard supersedes AHRI Standard 430-2009. See AHRI Standard 431 for SI ratings. Scope of Certification Program and Certified Ratings Please refer to the most current version of the Central Station Air-handling Units Supply Fans Certification Program Operations Manual (OM) for the Scope of the Certific
3、ation Program and Certified Ratings. IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommende
4、d that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-a
5、rt and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3. Definitions. 1 Section 4. Classifications . 3 Se
6、ction 5. Test Requirements 4 Section 6. Rating Requirements . 11 Section 7. Symbols and Subscripts 12 Section 8. Minimum Data Requirements for Published Ratings . 12 Section 9. Marking and Nameplate Data . 13 Section 10. Conformance Conditions 13 FIGURES Figure 1. Unducted Fan Discharge - Horizontal
7、 Arrangement 2 Figure 2. Ducted Fan Discharge - Horizontal Arrangement 3 Figure 3. Outlet Test Unit Configuration for Multiple Parallel Housed Fans in CSAHUs with Individual Ducted Discharges . 4 Figure 4. Single Outlet Test Unit Configuration for Single or Multiple Parallel Plenum Fans in CSAHUs wi
8、th Full Face Opening Axial Discharge. 5 Figure 5. Figure 15 Reprinted from “AMCA Publication 210-07, Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating”. 5 Figure 6. Figure 12 Reprinted from “AMCA Publication 210-07, Laboratory Methods of Testing Fans for Certified Aerod
9、ynamic Performance Rating” .6 Figure 7. Dimensions for Inlet Vane Proportionality 7 Figure 8. Ducted Fan Discharge CSAHU with Airflow Direction Change . 8 Figure 9. Fan and Unit Characteristics - Fan Rated and Unit Tested .10 Figure 10. Fan and Unit Characteristics - Fan Rated and Unit Calculated .1
10、1 APPENDICES Appendix A. References - Normative 14 Appendix B. References - Informative 14 Appendix C. Criteria for Proportionality-Informative 15 FIGURES FOR APPENDICES Figure C1. Dimensions Used for Proportionality Equations - Housed Fan . 17 Figure C2. Dimensions Used for Proportionality Equation
11、s - Plenum Fan . 17 Figure C3. Dimensions Used for Proportionality Equations - Axial Fan 17 Figure C4. Dimensions Used for Proportionality Equations - Multiple Fans (End Views) 18 _ AHRI STANDARD 430 (I-P)-2014 1 PERFORMANCE RATING OF CENTRAL STATION AIR-HANDLING UNIT SUPPLY FANS Section 1. Purpose
12、1.1 Purpose. The purpose of this standard is to establish for Central Station Air-handling Unit Supply Fans: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. Th
13、is standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Central Station
14、Air-handling Units, as defined in Section 3. 2.1.1 This standard applies to supply fan ratings for Plenum Fans in a cabinet with a Full Face Opening Axial Discharge, Housed Centrifugal Fans, and Axial Fans. 2.2 Exclusions. 2.2.1 This standard does not apply to forced-circulation, free-delivery air-c
15、oolers for refrigeration, which are covered in ANSI/AHRI Standard 420. 2.2.2 This standard does not apply to unit heaters intended for free delivery of heated air or to room fan-coils as defined in ANSI/AHRI Standard 440. 2.2.3 This standard does not apply to units that have direct expansion coils i
16、ncorporated by the manufacturer in a matched split system air-conditioner, or as otherwise defined in the product scope definition of the AHRI Unitary Small Equipment and Unitary Large Equipment Sections and covered in ANSI/AHRI Standard 210/240 or in ANSI/AHRI Standard 340/360. 2.2.4 This standard
17、does not apply to unit ventilators as defined in ANSI/AHRI Standard 840. 2.2.5 This standard does not apply to variable refrigerant flow equipment as defined in ANSI/AHRI Standard 1230. 2.2.6 This standard does not apply to DX Dedicated Outdoor Air System Units as defined in ANSI/AHRI Standard 920.
18、2.2.7 This standard does not apply to Computer and Data Processing Room Air Conditioners as defined in ANSI/AHRI Standard 1360. Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Terminology website (https:/www.ashrae.org/resources-publicati
19、ons/free-resources/ashrae-terminology) unless otherwise defined in this Section. 3.1 Actual Cubic Feet Per Minute (ACFM), cfm. The unit of airflow airflow uncorrected for air density. All airflow in this standard is considered to be actual airflow rate. 3.2 Central Station Air-handling Unit (CSAHU).
20、 A factory-made encased assembly consisting of a supply fan or fans in parallel which may also include other necessary equipment to perform one or more of the functions of circulating, cleaning, AHRI STANDARD 430 (I-P)-2014_ 2 heating, cooling, humidifying, dehumidifying and mixing of air. It shall
21、not contain a source of mechanical cooling. This assembly is capable of use with duct work having a total static resistance of at least 0.5 in H2O. 3.2.1 Ducted Fan Discharge Central Station Air-handling Unit. A unit that has a ducted fan outlet. (See Figure 2. Note that Figure 2 aapplies to HousedH
22、oused Centrifugal Fan and Axial Fans and that a Housed Centrifugal Fan is sshown.) 3.2.2 Unducted Fan Discharge Central Station Air-handling Unit. A unit containing a fan that does not have a ducted fan outlet. (See Figure 1. Note that Figure 1 applies to all fan types in the standard and that a Hou
23、sed Centrifugal Fan is shown.) 3.3 Full Face Opening Axial Discharge. Where the discharge opening of the CSAHU is the same cross-sectional dimensions as the interior of the CSAHUs casing and the direction of the airflow is parallel with the shaft of the fan or fans. 3.4 Supply Fan. The fan that prov
24、ides enough pressure to overcome the supply air restriction and may provide some or all of the pressure to overcome the return air restriction to provide air into the conditioned space. 3.4.1 Horizontal Shaft. A fan shaft that is parallel to the ground. 3.4.2 Vertical Shaft. A fan shaft that is perp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI430IP2014PERFORMANCERATINGOFCENTRALSTATIONAIRHANDLINGUNITSUPPLYFANSPDF

链接地址:http://www.mydoc123.com/p-422532.html