AHRI 340 360 I-P-2015 Performance Rating of Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment.pdf
《AHRI 340 360 I-P-2015 Performance Rating of Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment.pdf》由会员分享,可在线阅读,更多相关《AHRI 340 360 I-P-2015 Performance Rating of Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment.pdf(68页珍藏版)》请在麦多课文档分享上搜索。
1、 Price $10.00 (M) $20.00 (NM) Copyright 2015, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office AHRI Standard 340/360 (I-P)-2015 2015 Standard for Performance Rating of Commercial and Industrial Unitary Air-conditioning a
2、nd Heat Pump Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that product
3、s be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepte
4、d industry practices. AHRI does not certify or guarantee that any test conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This 2015 standard supersedes AHRI Standard 340/360-2007 with Addendum 1 and 2 and shall be effective January 1, 2017. AHRI CERTIFICATION PRO
5、GRAM PROVISIONS Scope of the Certification Program The Certification Program applies to 50 Hz and 60 Hz equipment including: Unitary Air-conditioners and Heat Pumps from 65,000 Btu/h to less than 250,000 Btu/h; o Single Packaged and Split Systems o Air-cooled and water-cooled Air-cooled Air-conditio
6、ning Condensing Units from 135,000 Btu/h to less than 250,000 Btu/h (covered by AHRI Standard 365); Air-cooled Single Packaged Unitary Air-conditioners from 250,000 Btu/h to less than 760,000 Btu/h. Products sold in the intended market of the US and Canada must comply with the “certify all requireme
7、nts”. For 60 Hz and 50 Hz products sold outside the intended market of the US and Canada, certification is optional. If the participant does not wish to carry certification of a model sold for use outside the intended market, this product shall carry a separate and unique model number from an existi
8、ng AHRI certified model number to avoid market confusion. Certified Ratings The following certified ratings are verified by test: Unitary Air-conditioners Air-cooled, water-cooled and evaporatively-cooled from 65,000 Btu/h to below 250,000 Btu/h. 1. Cooling Capacity, Btu/h at Standard Rating Conditi
9、ons 2. Energy Efficiency Ratio, EER, Btu/Wh at Standard Rating Conditions 3. Integrated Energy Efficiency Ratio, (IEER), Btu/Wh at Standard Rating Conditions Unitary Air-Cooled Packaged Air-Conditioners from 250,000 Btu/h to less than 760,000 Btu/h. 1. Cooling Capacity, Btu/h at Standard Rating Cond
10、itions 2. Energy Efficiency Ratio, EER, Btu/Wh at Standard Rating Conditions 3. Integrated Energy Efficiency Ratio, (IEER), Btu/Wh at Standard Rating ConditionsAir-source Unitary Heat Pump Equipment Air-cooled from 65,000 Btu/h to below 250,000 Btu/h. 1. Cooling Capacity, Btu/h at Standard Rating Co
11、nditions 2. Energy Efficiency Ratio, EER, Btu/Wh at Standard Rating Conditions 3. Integrated Energy Efficiency Ratio, IEER, Btu/Wh at Standard Rating Conditions 4. High Temperature Heating Standard Rating Capacity, Btu/h at 47F 5. High Temperature Coefficient of Performance, COPH, W/W, at 47F 6. Low
12、 Temperature Heating Standard Rating Capacity, Btu/h, at 17F 7. Low Temperature Coefficient of Performance, COPH, W/W, at 17F Conformance to the requirements of the maximum operating condition test, cooling low temperature operation test, insulation efficiency test (cooling), and condensate disposal
13、 test (cooling) are also verified initially by test for manufacturers applying into the AHRI ULE Certification Program. Foreword: AHRI Standard 340/360 2015 contains many significant revisions to the 2007 standard. 1. The revised standard includes definition and test requirements for Double-duct com
14、mercial unitary equipment. 2. Definitions have been expanded and clarified including an updated definition for IEER. 3. Table 1, Classification of Commercial and Industrial Unitary Air-Conditioner Equipment has been rewritten for clarity. 4. Table 2, Classification of Commercial and Industrial Unita
15、ry Heat Pump Equipment has been rewritten for clarity. 5. The part load efficiency, IEER, test method is simplified by eliminating the iterative OD test conditions needed to achieve a desired load point. The new method requires an additional test point at known conditions to be run in order to inter
16、polate to the desired load point. This simplifies the test procedure (Table 6). This method also reduces the uncertainty with the addition of a 3% tolerance for part load percent. 6. Section 5, Test Requirements, has been expanded to cover items not documented in ASHRAE Standard 37. 7. The standard
17、adds a tolerance of 3% on required part load Percent Load point where interpolation and degradation is not required (Table 7). 8. The revised standard includes optional International Rating Conditions (Section 6.3) relevant to international requirements that may be used optionally. The Rating Condit
18、ions are intended to align with ISO 5151, 13253 and 15042 conditions. 9. The standard includes a step by step procedure to generate IEER ratings based on either test method or computer simulation. This also includes clarification on procedures for fixed, capacity, staged capacity and variable capaci
19、ty units (Section 6.4). 10. Verification test uncertainty allowances have been explained and clarified for the performance metrics in the standard. (Section 6.5 classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking a
20、nd nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, federal and state regulations, and efficiency standards developed by American Society of Heating, Refrigerating, and A
21、ir-Conditioning Engineers (ASHRAE), International Energy Conservation Code (IECC), Canadian Standards Association (CSA), Department of Energy (DOE), and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standa
22、rd applies to factory-made Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment as defined in Section 3. 2.1.1 Energy Source. This standard applies only to electrically operated, vapor compression refrigeration systems. 2.2 Exclusions. This standard does not apply to the follow
23、ing: 2.2.1 Rating and testing of individual assemblies, such as condensing units or coils, for separate use. 2.2.2 Unitary Air-conditioners and Unitary Heat Pumps as defined in ANSI/AHRI Standard 210/240, with capacities less than 65,000 Btu/h. 2.2.3 Water-Source Heat Pumps as defined in ISO/ANSI/AH
24、RI/ASHRAE 13256-1. 2.2.4 Variable Refrigerant Flow Air Conditioners and Heat Pumps as defined in ANSI/AHRI Standard 1230. 2.2.5 Rating of units equipped with desuperheater/water heating devices (as defined in ANSI/AHRI Standard 470) in operation. 2.2.6 Commercial and Industrial Condensing Units with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI340360IP2015PERFORMANCERATINGOFCOMMERCIALANDINDUSTRIALUNITARYAIRCONDITIONINGANDHEATPUMPEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-422521.html