AHRI 300-2008 Sound Rating and Sound Transmission Loss of Packaged Terminal Equipment.pdf
《AHRI 300-2008 Sound Rating and Sound Transmission Loss of Packaged Terminal Equipment.pdf》由会员分享,可在线阅读,更多相关《AHRI 300-2008 Sound Rating and Sound Transmission Loss of Packaged Terminal Equipment.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 2008 Standard for Sound Rating and Sound Transmission Loss of Packaged Terminal Equipment ANSI/AHRI Standard 300 (Formerly ARI Standard 300) Price $10.00 (M) $20.00 (NM) Copyright 2008, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and T
2、rademark Office IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be de
3、signed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted indus
4、try practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 300-2000. Note: This version of the standard differs from the 2000 version of the standard in the following:
5、a. The tone adjusted A-Weighted Sound Power Level (LWAT) has been eliminated. b. An optional Sound Quality Indicator (SQI) per AHRI Standard 1140 has been added. c. This standard references AHRI Standard 220 for reverberation room qualification and testing, replacing ANSI Standard S12.31 and ANSI St
6、andard S12.32, which were withdrawn. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope .1 Section 3. Definitions .1 Section 4. Test Requirements .2 Section 5. Rating Requirements .3 Section 6. Minimum Data Requirements for Published Ratings 4 Section 7. Marking and Nameplate Data
7、4 Section 8. Conformance Conditions .4 APPENDICES Appendix A. References - Normative .5 Appendix B. References Informative 6 ANSI/AHRI STANDARD 300-2008 1 SOUND RATING AND SOUND TRANSMISSION LOSS OF PACKAGED TERMINAL EQUIPMENT Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establ
8、ish, for packaged terminal equipment: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; and conformance conditions. Additionally, this standard establishes a method to determine sound transmission loss for Packaged Terminal Equipment. 1.1.1 Intent.
9、 This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to the indoor and
10、 outdoor sections of factory-made Packaged Terminal Equipment as defined in AHRI Standard 310/380. Section 3. Definitions All terms in this document shall follow the standard industry definitions established in the current edition of ASHRAE Terminology of Heating, Ventilation, Air-Conditioning and R
11、efrigeration, unless otherwise defined in this section. 3.1 Octave Band. A band of sound covering a range of frequencies such that the highest is twice the lowest. The Octave Bands used in this standard are those defined in ANSI Standard S1.11. 3.2 One-Third Octave Band. A band of sound covering a r
12、ange of frequencies such that the highest frequency is the cube root of two times the lowest. The One-Third Octave Bands used in this standard are those defined in ANSI Standard S1.11. 3.3 Outdoor-Indoor Transmission Class (OITC). The A-weighted sound reduction calculated using the equipment sound t
13、ransmission loss in the range of 80 to 4000 Hz, as measured in accordance with ASTM 1332 Test Method E90. 3.4 Packaged Terminal Air-Conditioner. A wall sleeve and a separate unencased combination of heating and cooling assemblies specified by the builder and intended for mounting through the wall. I
14、t includes a prime source of refrigeration, separable outdoor louvers, forced ventilation and heating availability by purchasers choice of at least hot water, steam or electric resistance heat. 3.5 Packaged Terminal Heat Pump. A separate unencased refrigeration system installed in a cabinet of simil
15、ar function and configuration to that of a Packaged Terminal Air-Conditioner. It utilizes reverse cycle refrigeration as its prime heat source and has other supplementary heat source availability by purchasers choice of at least hot water, steam or electric resistance heat. 3.6 Published Rating. A s
16、tatement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating incl
17、udes the ANSI/AHRI STANDARD 300-2008 2 rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.6.1 Application Rating. A rating based on tests performed at application R
18、ating Conditions (other than Standard Rating Conditions). 3.6.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.7 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance t
19、o occur. 3.7.1 Standard Rating Conditions. Rating conditions used as the basis of comparison for performance characteristics. 3.8 Reference Sound Source (RSS). A portable, aerodynamic sound source that produces a known stable broadband sound. 3.9 “Shall” or “Should”. “Shall” or “should” shall be int
20、erpreted as follows: 3.9.1 Shall. Where “shall” or “shall not” is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.9.2 Should. “Should” is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.10 Sound
21、 Power Level, Lw. Ten times the logarithm to the base ten of the ratio of the sound power radiated by the source to a reference sound power, expressed in decibels (dB). The reference sound power used in this standard is 1 picowatt (pW). 3.10.1 A-Weighted Sound Power Level, LwA. The logarithmic summa
22、tion of A-Weighted, one-third octave band Sound Power Levels. 3.11 Sound Quality Indicator (SQI). The calculated metric determined when following the procedure contained in AHRI Standard 1140 for quantifying sound quality whereby measured sound levels are weighted to adjust for psychoacoustic sensit
23、ivity to frequency distribution and any discreet tones which may be present and then converted to a single number Sound Quality Indicator. 3.12 Sound Transmission Class (STC). A single-number rating derived from sound transmission loss data in accordance with the method described in ASTM Standard E4
24、13. Section 4. Test Requirements 4.1 Test Requirements. All standard sound power level ratings shall be determined by tests conducted in a reverberation room meeting the requirements of and qualified in accordance with AHRI Standard 220 except as noted within the body of this standard. Sound Power L
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI3002008SOUNDRATINGANDSOUNDTRANSMISSIONLOSSOFPACKAGEDTERMINALEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-422518.html