AHRI 1280-2014 Sound Power Rating of Water-cooled Chillers.pdf
《AHRI 1280-2014 Sound Power Rating of Water-cooled Chillers.pdf》由会员分享,可在线阅读,更多相关《AHRI 1280-2014 Sound Power Rating of Water-cooled Chillers.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、 2014 Standard for Sound Power Rating of Water-cooled Chillers AHRI Standard 1280 Price $10.00 (M) $20.00 (NM) Copyright 2014, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY DISCLAIMER AHRI does not se
2、t safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in ac
3、cordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any t
4、ests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This is a new standard. At each of the four Integrated Part Load Value (IPLV) load points, the following ratings are required: Un-weighted octave band Sound Power Levels, dB (63 Hz to 8,000 Hz) Overall A-wei
5、ghted Sound Power Level, dB (A-weighted 50 Hz to 10,000 Hz) Optional Information: Un-weighted one-third octave band Sound Power Levels, dB (50 Hz to 10,000 Hz) TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope .1 Section 3. Definitions.1 Section 4. Test Requirements 3 Section 5. R
6、ating Requirements .3 Section 6. Minimum Data Requirements for Published Ratings .4 Section 7. Conformance Conditions 5 APPENDICES Appendix A. References Normative 6 Appendix B. References Informative 6 Appendix C. Example Calculation of Octave Band Sound Power Levels Informative 7 Appendix D. Examp
7、le Calculation of A-weighted Sound Power Levels Informative 8 Appendix E. Determining Sound Power Levels Using Sound Pressure Measurements Made in a Reverberation Room Normative .9 Appendix F. Determining Sound Power Levels Using Sound Pressure Measurements Made in a Free Field Over a Reflecting Pla
8、ne Normative .12 Appendix G. Possible Magnitude of Measurement Errors Informative 15 Appendix H. Determination of K2 Informative .16 TABLES FOR APPENDICES Table C1. Example Calculation of Octave Band Sound Power Levels, Lwi7 Table D1. Example Calculation of A-weighted Sound Power Levels, LwA8 Table
9、E1. Background Correction Limits by One-third Octave Band 11 Table G1. Maximum Standard Deviations of Sound Power Level Reproducibility Determined in Accordance with this Standard .15 Table H1. Required Number of RSS Positions based on Parallelepiped Length .16 FIGURES FOR APPENDICES Figure F1. Thre
10、e Dimensional View of Measurement Parallelepiped .13 Figure H1. Schematic of RSS Locations Required for Determination of K2 19 AHRI STANDARD 1280-2014_ 1 SOUND POWER RATING OF WATER-COOLED CHILLERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish methods for determining t
11、he sound power ratings of commercial and industrial Water-cooled Chillers. It establishes definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guid
12、ance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to commercial and industrial Water-cooled Chillers used
13、for refrigerating or air-conditioning of spaces, as defined in Section 3 of this standard and covered by ANSI/AHRI Standards 550/590 (I-P) and 551/591 (SI), Performance Rating of Water Chilling Packages Using the Vapor Compression Cycle. 2.2 Exclusions. This standard does not apply to air-cooled equ
14、ipment, which falls within the scope of ANSI/AHRI Standard 270, Sound Rating of Outdoor Unitary Equipment and ANSI/AHRI Standard 370, Sound Performance Rating of Large Outdoor Refrigerating and Air-conditioning Equipment. Section 3. Definitions All terms in this document will follow the standard ind
15、ustry definitions in the ASHRAE Terminology website (https:/www.ashrae.org/resources-publications/free-resources/ashrae-terminology) unless otherwise defined in this section. 3.1 Comparison Method. A method of determining Sound Power Level of the equipment under test in a reverberation room by compa
16、ring the average Sound Pressure Level of that equipment to the average Sound Pressure Level of a Reference Sound Source of known Sound Power Level output. The difference in Sound Power Level is equal to the difference in Sound Pressure Level when conditions in the room are the same for both sets of
17、measurements. 3.2 Hertz (Hz). A unit of frequency equal to one cycle per second. 3.3 Integrated Part-Load Value (IPLV). A single number part-load efficiency figure of merit calculated per the method described in ANSI/AHRI Standards 550/590 (I-P) and 551/591 (SI) at Standard Rating Conditions. 3.4 Oc
18、tave Band. A band of sound covering a range of frequencies such that the highest is twice the lowest. The Octave Bands used in this standard are those defined in ANSI Standard S1.11. 3.5 One-third Octave Band. A band of sound covering a range of frequencies such that the highest frequency is the cub
19、e root of two times the lowest. The One-third Octave Bands used in this standard are those defined in ANSI Standard S1.11. 3.6 Published Rating. A statement of the assigned values of those performance characteristics, under stated IPLV rating conditions, by which a unit may be chosen to fit its appl
20、ication. These values apply to all units of like _AHRI STANDARD 1280-2014 2 nominal size and type (identification) produced by the same manufacturer. As used herein, the term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, adv
21、ertising or other literature controlled by the manufacturer, at stated IPLV rating conditions. 3.6.1 Application Rating. A rating based on tests performed at Application Rating Conditions (other than Standard Rating Conditions). 3.6.2 Standard Rating. A rating based on tests performed at Standard IP
22、LV Rating Conditions. 3.7 Rating Conditions. Any set of operating conditions under which a single level of performance results, and which cause only that level of performance to occur. 3.7.1 Standard IPLV Rating Conditions. Rating Conditions used as the basis of comparison for performance characteri
23、stics. 3.8 Reference Sound Source (RSS). A portable, aerodynamic sound source that produces a known stable broad band sound power output. 3.9 “Shall“ or “Should.“ “Shall“ or “should“ shall be interpreted as follows: 3.9.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that pr
24、ovision is mandatory if compliance with the standard is claimed. 3.9.2 Should. “Should“ is used to indicate provisions which are not mandatory but are desirable as good practice. 3.10 Sound Intensity. The average sound power transmitted through a unit area. 3.11 Sound Intensity Level, Li. This is te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI12802014SOUNDPOWERRATINGOFWATERCOOLEDCHILLERSPDF

链接地址:http://www.mydoc123.com/p-422494.html