《AECMA TR 4646-2008 Aerospace series Termination procedure for EN 4531 optical contact Edition 1《航空航天系列.EN 4531标准光学接触用终止程序.版本1》.pdf》由会员分享,可在线阅读,更多相关《AECMA TR 4646-2008 Aerospace series Termination procedure for EN 4531 optical contact Edition 1《航空航天系列.EN 4531标准光学接触用终止程序.版本1》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、ASD Technical Report Rapport Technique ASD ASD Fachbericht TR 4646 Edition 1 December 2008 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 763 3565 - www.asd-stan.orgICS: Descripto
2、rs: ENGLISH VERSION Aerospace series Termination procedure for EN 4531 optical contact Srie arospatiale Procdure de cblage pour contact optique EN 4531 Luft- und Raumfahrt Montageanleitung, fr Kontakte nach EN 4531 This Technical Report was drawn up by the Electrical Domain of ASD-STAN. The reason w
3、hich led to the publication of the document as a Technical Report is explained in the foreword. Edition approved for publication 31 December 2008 Electrical Domain Copyright 2008 by ASD-STAN Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permi
4、tted without license from IHS-,-,-Page 2 TR 4646:12-08 Contents Page Foreword2 1 EN 4531-101 contact terminus assembly 3 2 Normative references 3 3 Safety summary .3 4 Cable and fibre preparation3 5 Installation of the EN 4531 contact onto the fibre6 6 Fibre cleave . 11 7 Fibre end polishing. 11 7.1
5、 General definitions before starting. 11 7.2 Coarse polishing. 13 7.3 Fine polishing AUTOMATIC. 13 7.4 Quality check. 13 8 Installation of the terminus into a circular connector. 16 9 Insertion of the EN 4531-101 contact terminus into a rectangular ARINC style connector. 18 Foreword The main task of
6、 ASD-STAN Technical Committees is to prepare EN Standards, in exceptional circumstances however, the publication of Technical Report of one of the following types may be proposed: Type 1, the subject is still under technical development requiring wider exposure; Type 2, a Technical Committee has col
7、lected data of a different kind from that which is normally published as a European Standard. The Electrical Domain decided to publish this document in the form of a Technical Report of type 2 in order to facilitate the updating of this document. Copyright ASD-STAN Provided by IHS under license with
8、 AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 TR 4646:12-08 1 EN 4531-101 contact terminus assembly This termination process defines the stages to reach the minimum qualification requirements for the EN 4531 contact in accordance with EN 4531-001. O
9、ther processes could be applied if they conform to the minimum qualification requirements and with common agreement between manufacturer and user. This standard aims at cable termination within manufacturing facility. CAUTION Training and qualification of personnel terminating fibre optic contacts i
10、s mandatory. Throughout the termination process, cleanliness is critical to obtain high optical quality termination. Ensure that work areas are kept as clean as possible to minimize the ingress of dirt into the connector parts. NOTE Verify that the epoxy adhesive shelf life has not expired. Do not u
11、se epoxy adhesive with an expiration date that has passed. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (in
12、cluding any amendments) applies. EN 4531-001, Aerospace series Connectors, optical, circular, single and multipin, coupled by threaded ring Flush contacts Part 001: Technical specification. EN 4531-101, Aerospace series Connectors, optical, circular, single and multipin, coupled by threaded ring Flu
13、sh contacts Part 101: Optical contact for EN 4641-100 cable 55 C to 125 C Product standard. 3 Safety summary The following safety precautions shall be observed: a) Safety glasses shall be worn at all times when handling bare fibres or dispensing epoxy adhesive. b) To reduce the chance of skin contam
14、ination wear suitable disposable gloves i.e. surgical latex gloves. c) Do not touch the ends of the fibre as they may puncture the skin. Wash the hands after handling bare fibre. d) Avoid skin contact with epoxy adhesives. e) Never look directly into the end of a fibre. Before inspecting the end fac
15、e of a fibre, verify that the fibre is not emitting energy or use a microscope with integrated camera. 4 Cable and fibre preparation Step 1 Before termination, clean minimum of 10 cm of the outer jacket of the cable end with a suitable optical quality cleaning solution (for example Isopropyl Alcohol
16、 (IPA) impregnated wipes, or a lint free cloth dampened with the cleaning solution). Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 4 TR 4646:12-08 Cut the cable at an angle to facilitate the install
17、ation of the boot, see Figure 1. No strength member should protrude from the cable end. Figure 1 Cut cable at an angle Step 2 Install the cable marker sleeve and the supplied crimp sleeve, over the simplex cable (single fibre cable). Slide the cable marker sleeve, strain relief boot and the spring b
18、ack from the end of the simplex cable. See Figure 2. Key 1 Wire marker sleeve 2 Simplex cable 3 Spring 4 Strain relief boot Figure 2 Installing cable marker sleeve, strain relief boot and spring 2 FO 123 (Tx) DDFR 1 4 3Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo repr
19、oduction or networking permitted without license from IHS-,-,-Page 5 TR 4646:12-08 Step 3 Mark the simplex cable outer jacket to 20 mm and to 25 mm, mark the cable as shown in Figure 3 below. Dimensions in millimetres Key 1 Mark 2 Optical fibre 3 Buffer 4 Aramid yarn 5 Cable jacket Figure 3 EN 4531-
20、101 contact cable stripping dimensions Step 4 Remove the simplex cable jackets back to 20 mm using the simplex cable stripper and trim the aramid yarn using the strength member shears so that only 1 mm is left from the jacket. NOTE The optimum way to remove the simplex cable jackets is to ring cut t
21、he jacket with the simplex cable stripper and pull the jacket off by hand. Pushing off the simplex cable jacket with a tightly held simplex cable stripper can lead to fibre breakage. WARNING Wear safety glasses when removing the fibre buffer and coating to avoid possible eye injury. Step 5 Mark the
22、buffer at 17 mm. Remove the fibre buffer and coatings back to 17 mm using the buffer stripper. Remove the buffer and coating in small sections approximately 6 mm at a time. NOTE Normally, the buffer and coating are tightly adhered to one another and come off of the fibre at the same time. CAUTION Th
23、e uncoated fibre is in its most vulnerable state. Take extreme care not to damage the fibre. Breakage of any one fibre from this point until the connector is completely assembled will require repetition of this and the following steps in order to maintain approximately equal length of all the fibres
24、 in the cable. 3+ 0 1 2 45 1 17 192083+ 0 1 Copyright ASD-STAN Provided by IHS under license with AECMA Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 6 TR 4646:12-08 Step 6 Remove any residual coating material from the bare fibres with a wipe dampened with a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMATR46462008AEROSPACESERIESTERMINATIONPROCEDUREFOREN4531OPTICALCONTACTEDITION1 航空航天 系列 EN4531 标准 光学

链接地址:http://www.mydoc123.com/p-421803.html