AECMA PREN 3661-006-2005 Aerospace Series Circuit Breakers Single-Pole Temperature Compensated Rated Current 20 A to 50 A Part 006 With Polarized Signal Contact Bus Bar Version Pro.pdf
《AECMA PREN 3661-006-2005 Aerospace Series Circuit Breakers Single-Pole Temperature Compensated Rated Current 20 A to 50 A Part 006 With Polarized Signal Contact Bus Bar Version Pro.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 3661-006-2005 Aerospace Series Circuit Breakers Single-Pole Temperature Compensated Rated Current 20 A to 50 A Part 006 With Polarized Signal Contact Bus Bar Version Pro.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM prEN 3661-006 Edition P 1 May 2005 PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8110 - Fax. + 32 2 775 8111 - www.aecma-stan.orgICS: 49.060 Descriptors: ENGLISH VERSION Aerospac
2、e series Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A Part 006: With polarized signal contact Bus bar version Product standard Srie arospatiale Disjoncteurs unipolaires compenss en temprature, intensits nominales 20 A 50 A Partie 006 : Avec contact de signalisat
3、ion polaris Version pour barres bus Norme de produit Luft- und Raumfahrt Schutzschalter, einpolig, Temperaturkompensiert, Nennstrme von 20 A bis 50 A Teil 006: Mit polarisiertem Signalkontakt Sammelschienenversion Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibi
4、lity of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestand
5、ard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN)
6、to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with th
7、e EN. Edition approved for publication 31 May 2005 Comments should be sent within six months after the date of publication to AECMA-STAN Electrical Domain Copyright 2005 by AECMA-STAN Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANo
8、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3661-006:20052 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in A
9、ECMA-STANs General Process Manual, this standard has received approval for Publication. Contents Page 1 Scope . 3 2 Normative references 3 3 Dimensions and mass 3 4 Characteristics 5 5 Designation. 9 6 Rated current code. 10 7 Delivery codes. 10 8 Marking 10 9 Technical specification 10 Copyright As
10、sociation Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3661-006:20053 1 Scope This standard specifies the characteristics of single-pole circuit breakers, temperatur
11、e compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between 55 C and 125 C and at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action “trip-free“ tripping with a
12、polarized signal contact which is open when main contacts are closed, and inversely. They are connected on supply side by means of bus-bar.They will continue to function up to the short-circuit current. 2 Normative references The following referenced documents are indispensable for the application o
13、f this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3155-016, Aerospace series Electrical contacts used in elements of connection Part 016: Contacts, electrical, male, type
14、 A, crimp, class S Product standard.1)EN 3661-001, Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A Part 001: Technical specification.1)EN 3841-305, Aerospace series Circuit breakers Test methods Part 305: Short-circuit performance. EN 6113, Aerospa
15、ce series Circuit breaker, connecting and attachment hardware.1)TR 6083, Aerospace series Cut-outs for installation of electrical components.2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3)MIL-I-81969/14C, Installing and removal tools,
16、 connector electrical contact, type III, class 2, composition B.3)MIL-S-19500, Semiconductor device, diode, silicon, fast recovery.3)FED-STD-595B, Colours used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional characteristics The circuit breakers do not have to correspond to the picto
17、rial illustration, only the dimensions given shall be adhered to. Dimensions are in millimetres. See Figure 1. 1) Published as AECMA Prestandard at the date of publication of this standard 2) Published as AECMA Technical Report at the date of publication of this standard. 3) Published by: Department
18、 of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-prEN 3661-006:20054 1155323M12 x 0,75 10,4
19、0,43 min.2 0,3482519,5 max.34 max.42 max.10 min.10 min.10 9,2 0,3926,5 0,3180-123 148 128 max.6,6 0,64533 max.401325 max.7120-1 5 ,5+0,106129,5 0,1 248,2 0,515,1 min.r 2F2F1 and F2 : see EN 3661-001, table 3F1Bus-bar side40,2 max.550+1Key 1 Push button released 9 1 to 3 max. 2 Green colour according
20、 to FED-STD-595B No. 34090 10 3 White Gauge 20 connection pins according to EN 3155-016M2018 4 Marking area, see Clause 8. 11 Indicative value 30 5 (see note) 5 Connecting screw and washer 12 6 Push button pressed Positioning lug in accordance with the panel cut-out, as per TR6083C202 7 Lockwasher 1
21、3 Rated current marking (white on green) 8 Attachment nut NOTE Tools noted in Subclause 4.2.4 shall be applied without interfering with the terminal 2 connection. Even if the circuit breakers are grouped. Figure 1 Configuration Dimensions Tolerances F1 and F2: see EN 3661-001, Table 3. Copyright Ass
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN36610062005AEROSPACESERIESCIRCUITBREAKERSSINGLEPOLETEMPERATURECOMPENSATEDRATEDCURRENT20ATO50APART006WITHPOLARIZEDSIGNALCONTACTBUSBARVERSIONPROPDF

链接地址:http://www.mydoc123.com/p-420560.html