AASHTO T 336-2015 Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete.pdf
《AASHTO T 336-2015 Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete.pdf》由会员分享,可在线阅读,更多相关《AASHTO T 336-2015 Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete AASHTO Designation: T 336-151American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-3c T 336-1 AASHTO Standard Method of Test for C
2、oefficient of Thermal Expansion of Hydraulic Cement Concrete AASHTO Designation: T 336-1511. SCOPE 1.1. This test method covers determination of the coefficient of thermal expansion (CTE) of hydraulic cement concrete cores and cylinders. Because it is known that the degree of saturation of concrete
3、influences its measured coefficient of thermal expansion, the specimens must be in a saturated condition for this procedure. 1.2. The values stated in SI units shall be regarded as the standard. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: R 39, Making and Curing Concrete Test Specimens in the Lab
4、oratory T 22, Compressive Strength of Cylindrical Concrete Specimens T 23, Making and Curing Concrete Test Specimens in the Field T 24M/T 24, Obtaining and Testing Drilled Cores and Sawed Beams of Concrete 2.2. ASTM Standards: C670, Standard Practice for Preparing Precision and Bias Statements for T
5、est Methods for Construction Materials E228, Standard Test Method for Linear Thermal Expansion of Solid Materials with a Push-Rod Dilatometer E289, Standard Test Method for Linear Thermal Expansion of Rigid Solids with Interferometry 3. SUMMARY OF TEST METHOD 3.1. This method determines the CTE of a
6、 cylindrical concrete specimen, maintained in a saturated condition, by measuring the length change of the specimen due to a specified temperature change. The measured length change is corrected for any change in length of the measuring apparatus (previously determined), and the CTE is then calculat
7、ed by dividing the corrected length change by the temperature change and then the specimen length, as described in the section on calculations. 4. SIGNIFICANCE AND USE 4.1. Measurement of the CTE permits assessment of the potential for length/volume change of concrete due to a uniform temperature ch
8、ange and of the potential deformation of a concrete structure due to a temperature gradient through the concrete. As an example, for pavement slabs 2016 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-3c T
9、 336-2 AASHTO on grade, uniform temperature change will affect the openings at joints and a temperature gradient through the thickness of these same slabs will produce curling of the slabs. The results of this test can be used to better estimate slab movement and stress development due to temperatur
10、e change. 5. APPARATUS 5.1. Concrete SawCapable of sawing the ends of a cylindrical specimen perpendicular to the axis and parallel to each other. 5.2. BalanceA scale or balance having a capacity of 20 kg (44 lb) and an accurateness of 0.1 percent over its range. 5.3. CaliperComparator or other suit
11、able device to measure the specimen length to the nearest 0.1 mm (0.004 in.). 5.4. Calibration SpecimenA calibration specimen with a known coefficient of thermal expansion shall be used to determine the correction factor of the equipment. The specimen shall be composed of a material that is essentia
12、lly linearly elastic, noncorroding, nonoxidizing, nonporous, and nonmagnetic, and it shall have a known thermal coefficient of expansion not to exceed 20 micro strain/C determined over the temperature range of 10 to 50C (50 to 122F) (see Note 1). Option 1: An ISO 9001 or equivalent laboratory should
13、 determine the CTE of the calibration specimen according to ASTM E228 or ASTM E289 within the temperature range of 10 to 50C (50 to 122F) and provide a certificate of the CTE value (see Note 2). Option 2: Manufacturer determines the CTE of the calibration specimen determined from a properly calibrat
14、ed CTE device meeting T 336 requirements . The CTE device used to determine the CTE of calibration specimens must be calibrated and verified using specimens that have previously been determined following Option 1.The CTE value and date tested shall be marked on the calibration specimen. The diameter
15、 of the calibration specimen should be large enough to firmly rest on the semispherical support buttons of the frame described in Section 5.7 and the length should be 177.8 2.5 mm (7.0 0.1 in.) (see Note 3). Note 1Grade 304 stainless steel, titanium and nickel are suitable materials. Note 2Testing o
16、f a full-height specimen is preferred. If coupons are used to determine the CTE of the calibration specimen, care must be taken to ensure that the longitudinal direction of the coupon is in the same direction as the calibration specimen it represents. The coupons shall be obtained adjacent to the lo
17、cation where the full-height specimen was obtained. Note 3Different-length concrete specimens can be tested provided the frame is recalibrated and verified with specimens with lengths that are 2.54 mm (0.1 in.) of the concrete specimen to be tested. 5.5. Length Change Measurement DeviceThe sample le
18、ngth change shall be measured using any suitable apparatus that has sufficient resolution and gives reproducible results. In this standard, the use of a linear variable differential transducer (LVDT) is described. The LVDT with excitation source and digital readout shall have a minimum resolution of
19、 0.000125 mm (0.000005 in.) and a range suitable for the test. The semi-spherical contact tip (at the point of contact between the measuring device and the specimen) must be firmly attached to the length change measuring device to prevent loosening during a test (see Note 4). Note 4Submersible and n
20、onsubmersible LVDTs are suitable. 2016 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-3c T 336-3 AASHTO 5.6. Support FrameA rigid support frame for the specimen to be used during length change measurement
21、 (Note 5). The frame shall be designed to have minimal influence on the length change measurements obtained during the test and should support the specimen such that the specimen is allowed to freely adjust to any change in temperature. Any specimen measuring frame should be constructed with the fol
22、lowing features: 5.6.1. The frame should be made of a noncorroding material or be protected against corrosion, as necessary (see Note 5). Note 5Frames may be designed to accommodate different-length concrete specimens. Frames shall be calibrated and verified with specimens 2.54 mm (0.1 in) of the te
23、st specimen length. Figure X1.1 shows a schematic of a suitable measuring frame. 5.7. Temperature Measuring DeviceSubmersible temperature measuring device(s) with a resolution of 0.1C (0.2F) and an accuracy of 0.2C (0.4F), verified with a NIST traceable thermometer. 5.8. Verification SpecimenA speci
24、men, other than the calibration specimen with a known CTE used to verify that the equipment is operating properly. The specimen should be composed of a material that is essentially linearly elastic, noncorroding, nonoxidizing, nonporous, and nonmagnetic, and it should have a known thermal coefficien
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT3362015STANDARDMETHODOFTESTFORCOEFFICIENTOFTHERMALEXPANSIONOFHYDRAULICCEMENTCONCRETEPDF

链接地址:http://www.mydoc123.com/p-418277.html