1、Section 9 REINFORCING STEEL 9.1 DESCRIPTION the point of shipment to the jobsite shall conform to the requirements of AASHTO M 284 (ASTM D 3963) or ASTM A 934, as specified in the contract documents. Epoxy-coated reinforcing bars shall be coated in a cer- tified epoxy coating applicator plant in acc
2、ordance with the Concrete Reinforcing Steel Institutes Voluntary Cer- This work shall consist of furnishing and placing rein- forcing steel in accordance with these Specifications and in conformity with the plans. 9.2 MATERIAL tification Program for Fusion-Bonded Epoxy Coated Ap- plicator Plants, or
3、 equivalent. Epoxy-coated steel wire and welded wire fabric for re- inforcement shall conform to the requirements of ASTM A 884, Class A. Each shipment of epoxy-coated reinforcing steel shall be accompanied with a Certificate of Compliance signed All reinforcing bars shall be deformed except that pl
4、ain Reinforcing steel shall conform to the requirements of bars may be used for spirals and ties. the following specifications. by the applicator of the coating certifying that the epoxy- coated reinforcing bars conform to the requirements of AASHTO M 284 or ASTM A 934 or that the epoxy- coated wire
5、 or welded wire fabric conforms to ASTM A 884, Class A. 9.2.1 Uncoated Reinforcing Steel Deformed and Plain Billet-Steel Bars for Concrete Re- 31 (ASTM A 615). Grade 60 inforcement-AASHTO shall be used unless otherwise shown or specified. Low-Alloy Steel Deformed and Plain Bars for Con- 9.2.3 Stainl
6、ess Steel Reinforcing Bars Crete Reinforcement-ASTM A 706. Rail-Steel Deformed and Plain Bars for Concrete Re- inforcement-AASHTO M 42 including Supplementary Requirement S1 (ASTM A 616 including Supplementary Requirement Si). Grade 60 steel shall be used unless oth- erwise shown or specified. Defor
7、med Steel Wire for Concrete Reinforcement- AASHTO M 225 (ASTM A 496). Welded Plain Steel Wire Fabric for Concrete Rein- forcement-AASHTO M 55 (ASTM A 185). Plain Steel Wire for Concrete Reinforcement- AASHTO M 32 (ASTM A 82). Welded Deformed Steel Wire Fabric for Concrete Re- inforcement-AASHTO M 22
8、1 (ASTM A 497). When required by the contract documents, deformed or plain stainless steel reinforcing bars shall conform to the requirements of ASTM A 955 M. 9.2.4 Mill Test Reports Whenever steel reinforcing bars, other than bars con- forming to ASTM A 706, are to be spliced by welding or when oth
9、erwise requested, a certified copy of the mill test report showing physical and chemical analysis for each heat or lot of reinforcing bars delivered shall be provided to the Engineer. 9.2.2 Epoxy-Coated Reinforcing Steel 9.3 BAR LISTS AND BENDING DIAGRAMS The reinforcing steel to be epoxy coated sha
10、ll conform to Article 9.2.1. When epoxy coating of reinforcing bars is required, the coating materials and process, the fabrication, handling, identification of the bars, and the repair of damaged coat- ing material that occurs during fabrication and handling to When the plans do not include detaile
11、d bar lists and bending diagrams, the Contractor shall provide such lists and diagrams to the Engineer for review and approval. Fabrication of material shall not begin until such lists have been approved. The approval of bar lists and bending dia- grams shall in no way relieve the Contractor of resp
12、onsi- 549 550 HIGHWAY BRIDGES 9.3 bility for the correctness of such lists and diagrams. Any expense incident to the revision of material furnished in accordance with such lists and diagrams to make it com- ply with the design drawings shall be borne by the Con- tractor. 9.4 FABRICATION 9.4.1 Bendin
13、g Bar reinforcement shall be cut and bent to the shapes shown on the plans. Fabrication tolerances shall be in ac- cordance with AC1 315. All bars shall be bent cold, unless otherwise permitted. Bars partially embedded in concrete shall not be field bent except as shown on the plans or specifically
14、permitted. 9.4.2 Hooks and Bend Dimensions The dimensions of hooks and the diameters of bends measured on the inside of the bar shall be as shown on the plans. When the dimensions of hooks or the diameter of bends are not shown, they shall be in accordance with Di- vision I, Article 8.23 or AC1 318,
15、 “Building Code Re- quirements for Reinforced Concrete.” 9.4.3 Identification Bar reinforcement shall be shipped in standard bundles, tagged and marked in accordance with the Manual of Stan- dard Practice of the Concrete Reinforcing Steel Institute. 9.5 HANDLING, STORING, AND SURFACE CONDITION OF RE
16、INFORCEMENT Steel reinforcement shall be stored above the surface of the ground on platforms, skids, or other supports and shall be protected from mechanical injury and surface de- terioration caused by exposure to conditions producing rust. When placed in the work, reinforcement shall be free from
17、dirt, loose rust or scale, mortar, paint, grease, oil, or other nonmetallic coatings that reduce bond. Epoxy coat- ings of reinforcing steel in accord with standards in this article shall be permitted. Reinforcement shall be free from injurious defects such as cracks and laminations. Bonded rust, su
18、rface seams, surface irregularities, or mill scale will not be cause for rejection, provided the mini- mum dimensions, cross-sectional area, and tensile prop- erties of a hand wire brushed specimen meet the physical requirements for the size and grade of steel specified. Epoxy-coated reinforcing ste
19、el shall be handled and stored by methods that will not damage the epoxy coat- ing. All systems for handling epoxy-coated reinforce- ment bars shall have adequately padded contact areas. All bundling bands shall be padded and all bundles shall be lifted with a strong back, multiple supports, or plat
20、form bridge so as to prevent bar-to-bar abrasion from sags in the bundle. Bars or bundles shall not be dropped or dragged. Epoxy-coated reinforcing steel shall be stored on wooden or padded supports. Epoxy-coated reinforcing steel shall be protected from sunlight, salt spray, and weather exposure. P
21、rovisions shall be made for air circulation around the coated rein- forcement to minimize condensation under the protective covering. 9.6 PLACING AND FASTENING 9.6.1 General Steel reinforcement shall be accurately placed as shown on the plans and firmly held in position during the placing and consol
22、idation of concrete. Bars shall be tied at ail intersections around the perimeter of each mat and at not less than 2-foot centers or at every intersection, whichever is greater, elsewhere. Bundled bars shall be tied together at not more than 6-foot centers. For fasten- ing epoxy-coated reinforcement
23、, tie wire and metal clips shall be plastic-coated or epoxy-coated. If uncoated welded wire fabric is shipped in rolls, it shall be straight- ened into flat sheets before being placed. Welding of crossing bars (tack welding) will not be permitted for as- sembly of reinforcement unless authorized in
24、writing by the Engineer. 9.6.2 Support Systems Reinforcing steel shall be supported in its proper posi- tion by use of precast concrete blocks, wire bar supports, supplementary bars or other approved devices. Such rein- forcement supports or devices shall be of such height and placed at sufficiently
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONIISEC92002DIVISIONIICONSTRUCTIONREINFORCINGSTEEL 钢筋 PDF

链接地址:http://www.mydoc123.com/p-417604.html