AASHTO HB-17 DIVISION I SEC 10-2002 Division I Design - Structural Steel ((Part A Part B Part C and Part D) Errata 01 2003)《结构钢》.pdf
《AASHTO HB-17 DIVISION I SEC 10-2002 Division I Design - Structural Steel ((Part A Part B Part C and Part D) Errata 01 2003)《结构钢》.pdf》由会员分享,可在线阅读,更多相关《AASHTO HB-17 DIVISION I SEC 10-2002 Division I Design - Structural Steel ((Part A Part B Part C and Part D) Errata 01 2003)《结构钢》.pdf(86页珍藏版)》请在麦多课文档分享上搜索。
1、Section 10 STRUCTURAL STEEL Part A GENERAL REQUIREMENTS AND MATERIALS 10.1 APPLICATION Notations = area of cross section (Articles 10.37.1.1, 10.34.4, 10.48.1.1, 10.48.2.1, 10.48.4.2, 10.48.5.3, and 10.55.1) = bending moment coefficient (Article 10.50.1.1.2) = effective area of a flange or splice pl
2、ate with holes or a tension member with holes (Articles 10.12, 10.18.2.2.1, 10.18.2.2.3, 10.18.2.2.4, and 10.18.4.1) = amplification factor (Articles 10.37.1.1 and 10.55.1) = product of area and yield point for bottom flange of steel section (Article 10.50.1.1.1) = product of area and yield point of
3、 that part of reinforcing which lies in the compression zone of the slab (Article 10.50.1.1.1) = product of area and yield point for top flange of steel section (Article 10.50.1.1.1) = product of area and yield point for web of steel section (Article 10.50.1.1.1) = area of flange (Articles 10.39.4.4
4、.2, 10.48.2.1, 10.53.1.2, and 10.56.3) = the sum of the area of filler plates on the top and bottom of the connected plate (Article 10.18.1.2.1) = area of compression flange (Articles 10.48.4.1 and 10.50.1.2.1) = gross area of a flange, splice plate or tension member (Articles 10.18.2.2.2, 10.18.2.2
5、.4, and 10.18.4.1) = net section of a tension member (Article 10.18.4.1) = the smaller of either the connected plate area or the sum of the splice plate areas on the top and bottom of the connected plate (Article 10.18.1.2.1) A: As AS AS, Au a a a a B B b b b b b b b b = total area of longitudinal r
6、einforcing steel at the interior support within the effective Aange width (Article 10.38.5.1.2) = total area of longitudinal slab reinforcement steel for each beam over interior support (Ar- ticle 10.38.5.1.3) = area of steel section (Articles 10.38.5.1.2, 10.54.1.1, and 10.54.2.1) = cross-sectional
7、 area of a stud shear connector (Article 10.38.5.1.2) = area of web of beam (Article 10.53.1.2) = distance from center of bolt under con- sideration to edge of plate, in. (Articles 10.32.3.3.2 and 10.56.2) = spacing of transverse stiffeners (Article 10.39.4.4.2) = depth of stress block (Figure 10.50
8、A) = ratio of numerically smaller to the larger end moment (Article 10.54.2.2) = constant based on the number of stress cycles (Article 10.38.5.1.1) = constant for stiffeners (Articles 10.34.4.7 and 10.48.5.3) = compression flange width (Table 10.32.1A and Articles 10.34.2.1, 10.48, 10.48.1.1, 10.48
9、.2, 10.48.2.1, and 10.61.4) = distance from center of bolt under consider- ation to toe of fillet of connected part, in. (Ar- ticles 10.32.3.3.2 and 10.56.2) = effective width of slab (Article 10.50.1.1.1) = effective flange width (Articles 10.38.3 and = widest flange width (Article 10.15.2.1) = dis
10、tance from edge of plate or edge of perfo- ration to the point of support (Article 10.35.2.3) = unsupported distance between points of sup- port (Article 10.35.2.7) = flange width between webs (Articles 10.37.3.1, 10.39.4.2, 10.51.5.1, and 10.55.3) 10.38.5.1.2) 25 1 252 HIGHWAY BRIDGES 10.1.1 = widt
11、h of stiffeners (Articles 10.34.5.2, 10.34.6, 10.37.2.4, 10.39.4.5.1, and 10.55.2) = width of a projecting flange element, angle, or stiffener (Articles 10.34.2.2, 10.34.4.7, 10.37.3.2, 10.39.4.5.1, 10.48.5.3, 10.5 1 S.5, and 10.55.3) = web buckling coefficient (Articles 10.34.4, 10.38.1.7, 10.48.5.
12、3, and 10.48.8) = compressive force in the slab (Article 10.50.1.1.1) = equivalent moment factor (Article 10.54.2.1) = compressive force in top portion of steel cec- tion (Article 10.50.1.1.1) = bending coefficient (Table 10.32.1A and Ar- ticles 10.48.4.1 and 10.50.2.2) = column slenderness ratio di
13、viding elastic and inelastic buckling (Table 10.32.1A) = coefficient about X axis (Article 10.36) = coefficient about the Y axis (Article 10.36) = buckling stress coefficient (Article 10.51.5.2) = clear distance between flanges, in. (Article 1 O. 15.2) = clear unsupported distance between flange com
14、ponents (Articles 10.18.2.3.4,10.18.2.3.7, 10.18.2.3.8, 10.18.2.3.9, 10.34.3, 10.34.4, 10.34.5, 10.37.2, 10.48.1, 10.48.2, 10.48.4, 10.48.5,10.48.6, 10.48.8, 10.49.2, 10.49.3.2, 10.50.1.1.2, 10.50.2.1, 10.55.2, and 10.61.1) = distance from the top of the slab to the neu- tral axis at which a composi
15、te section in pos- itive bending theoretically reaches its plastic- moment capacity when the maximum strain in the slab is at 0.003 (Article 10.50.1.1.2) = clear distance between the neutral axis and the compression flange (Articles 10.34.3.2.1, 10.34.5.1, 10.48.4.1, 10.49.2, 10.49.3, 10.50(b), 10.5
16、7, and 10.61.1) = moments caused by dead load acting on com- posite girder (Article 10.50.1.2.2) = depth of the web in compression at the plas- tic moment (Articles 10.50(b), 10.50.1.1.2, and 10.50.2.1) = depth of the web in compression of the non- composite steel beam or girder skicles 10.34.5.1 an
17、d 10.49.3.2(a) = distance from the top of the slab to the plas- tic neutral axis, in. (Article 10.50.1.1.2) = moments caused by dead load acting on steel girder (Article 10.50.1.2.2) = bolt diameter (Table 10.32.3B) = diameter of stud, in, (Article 10.38.5.1) = depth of beam or girder, in. (Table 10
18、.32.1A and Articles 10.13, 10.48.2, 10.48.4.1, and 10.50.1.1.2) =diameter of rocker or roller, in. (Article 10.32.4.2) = beam depth (Article 10.56.3) = column depth (Article 10.56.3) = spacing of intermediate stiffener (Articles 10.34.4, 10.34.5, 10.48.5.3, 10.48.6.3, and 10.48.8) = distance from th
19、e centerline of a plate longi- tudinal stiffener or the gage line of an angle longitudinal stiffener to the inner surface or the leg of the compression flange component (Articles 10.34.3.2.1, 10.34.5.1, 10.48.4.1, 10.49.3.2(a), and 10.61.1) = modulus of elasticity of steel, psi (Table 10.32.1AandArt
20、icles 10.15.3, 10.36, 10.37, 10.39.4.4.2, 10.54.1, and 10.55.1) = modulus of elasticity of concrete, psi (Article 10.38.5.1.2) = distance from the centerline of a splice to the centroid of the connection on the side of the joint under consideration (Articles 10.18.2.3.3, 10.18.2.3.5, and 10.18.2.3.7
21、) = maximum induced stress in the bottom flange (Article 10.20.2. i) = maximum compressive stress, psi (Article 10.41.4.6) = allowable axial unit stress (Table 10.32.1A and Articles 10.36, 10.37.1.2, and 10.55.1) = allowable bending unit stress (Table 10.32.1A and Articles 10.18.2.2.3, 10.37.1.2, an
22、d 10.55.1) = compressive bending stress permitted about the X axis (Article 10.36) = compressive bending stress permitted about the Y axis (Article 10.36) = buckling stress of the compression flange plate or column (Articles 10.48.2, 10.50.2.2, 10.51.1, 10.51.5, 10.54.1.1, and 10.54.2.1) = local buc
23、kling stress of a stiffener (Articles 10.34.4.7 and 10.48.5.3) = design stress for the controlling flange at a point of splice (Articles 10.18.2.2.3 and 10.18.2.3.8) = design stress for the controlling flange at a point of splice (Articles 10.18.2.2.1 and 10.18.2.3.4) = maximum horizontal force (Art
24、icle = Euler buckling stress (Articles 10.37.1, 10.20.2.2) 10.54.2.1, and 10.55.1) 10.1.1 DIVISION I-DESIGN 253 = Euler stress divided by a factor of safety (Ar- = design stress for the noncontrolling flange at = design stress for the noncontrolling flange at = computed bearing stress due to design
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONISEC102002DIVISIONIDESIGNSTRUCTURALSTEELPARTAPARTBPARTCANDPARTDERRATA012003 结构钢 PDF

链接地址:http://www.mydoc123.com/p-417550.html