1、 STD-APIIPETRO PUBL 340-ENGL 1777 W 0732270 0572051 LO7 I I Liquid Release Prevention and Detection Measures for Aboveground Storage Facilities Health and Environmental Affairs Department API PUBLICATION NUMBER 340 PREPARED UNDER CONTRACT BY: JOSEPH S. BURKE SPEC CONSULTING SERVICES 1 O WILDWOOD COV
2、ER PO BOX 912 CLIFTON PARK, NEW YORK 12065 OCTOBER 1997 American Petroleum Institute FOREWORD API PUBLICATIONS NECESSARILY ADDRESS PROBLEMS OF A GENERAL NATURE. WITH RESPECT TO PARTICULAR CIRCUMSTANCES, LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS SHOULD BE REVIEWED. API IS NOT UNDERTAKING TO MEET
3、 THE DUTIES OF EMPLOYERS, MANUFAC- TURERS, OR SUPPLIERS TO WARN AND PROPERLY TRAIN AND EQUIP THEIR EMPLOYEES, AND OTHERS EXPOSED, CONCERNING HEALTH AND SAFETY RISKS AND PRECAUTIONS, NOR UNDERTAKING THEIR OBLIGATIONS UNDER LOCAL, STATE, OR FEDERAL LAWS. NOTHING CONTAINED IN ANY API PUBLICATION IS TO
4、BE CONSTRUED AS GRANTING ANY RIGHT, BY IMPLICATION OR OTHERWISE, FOR THE MANU- FACTURE, SALE, OR USE OF ANY METHOD, APPARATUS, OR PRODUCT COV- ERED BY LETTERS PATENT. NEITHER SHOULD ANYTHING CONTAINED IN ITY FOR INFRINGEMENT OF LETTERS PATENT. THE PUBLICATION BE CONSTRUED AS INSURING ANYONE AGAINST
5、LIABIL- All rights reserved. No part of this work may be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher: Contact the publisher; API Publishing Services, I220 L S
6、treet, N. W, Washington, D.C. 20005. Copyright 8 1997 American Petroleum Institute iii ACKNOWLEDGMENTS THE FOLLOWING PEOPLE ARE RECOGNIZED FOR THEIR CONTRIBUTIONS OF TIME AND EXPERTISE DURING THIS STUDY AND IN THE PREPARATION OF THIS REPORT: API STAFF CONTACT F. Dee Gavora, Health and Environmental
7、Affairs MEMBERS OF THE STORAGE TANK TASK FORCE SUBCOMMmE Jerry Bolra, Shell Oil Company Jerry Engelhardt, Santa Fe Pacific Pipeline Company Donald Gilson, Chevron Products Company Donald Hitchcock, Texaco Refining and Marketing George Loyd, Shell Oil Company William Martin, ARCO Products Company Gen
8、e Milunec, Mobil Oil Corporation James Moore, AMOC0 Oil Company Philip Myers, Chevron Research and Technology James Scott, 76 Products Company Ned Seppi, Marathon Oil Company Randy Steele, BP Oil Company James Stevenson, Phillips Pipeline Company John Thomas, Shell Oil Company Alan Wolf, Exxon Resea
9、rch and Engineering Company John Zimmer, Mobil Oil Corporation IV STD.API/PETRO PUBL U-ENGL iqw m 0732290 0572055 852 m TABLE OF CONTENTS Section Pase EXECUTIVE SUMMARY i . ES- 1 1 . INTRODUCTION . 1-1 Background 1-1 Scope of Report . 1-2 Facilities Addressed 1-3 Who Should Read This Report . 1-3 A
10、Note of Caution 1-3 2 . SELECTION CRITERIA 2-1 General Approach 2-1 Consideration of Selection Criteria . 2-2 3 . DESIGN OF THE TABLES 3-1 Overview 3-1 References to Cost . 3-1 4 . ABOVEGROUND STORAGE TANKS 4-1 Introduction . 4-1 Overview 4-1 Release Scenarios . 4-2 Release Prevention . 4-3 5 . PIPI
11、NG SYSTEMS . 5-1 Overview 5-1 Introduction . 5-1 Release Scenarios . 5-3 Release Prevention . 5-3 STD.API/PETRO PUBL 340-ENGL 1777 0732290 057205b 717 6 . LOADING AND UNLOADING SYSTEMS . 6-1 Introduction . 6-1 Overview 6-1 Release Scenarios . 6-2 Release Prevention . 6-2 7 . ANCILLARY FACILITY EQUIP
12、MENT 7-1 Introduction . 7-1 Overview 7-2 Release Scenarios . 7-2 Release Prevention . 7-2 8 . OPERATING SYSTEMS 8-1 Introduction . 8-1 Overview 8-1 Release Scenarios . 8-2 Release Prevention 8-3 BIBLIOGRAPHY . R- 1 Appendix A LIST OF ABBREVIATIONS AND/OR GLOSSARY . A-1 Appendix B DEFDTITIONS B- 1 Fi
13、gure 1-1 2- 1 LIST OF FIGURES Sources of Potential Releases at AST Facilities . 1-5 Hierarchy for Selection of Control Measures 2-1 Table ES- 1 4- 1 4-2 5- 1 5-2 6- 1 6-2 7- 1 7-2 8- 1 8-2 STD-APIIPETRO PUBL 340-ENGL 1997 0732290 0572057 b25 E LIST OF TABLES Overview of Liquid Release and Detection
14、Measures at AST Facilities . e5-2 Aboveground Storage Tank Release Scenarios . 4-5 Aboveground Storage Tank Prevention and Detection Measures 4-10 Piping System Release Scenarios 5-6 Piping System Prevention and Detection Measures . 5-12 Loading and Unloading Systems Release Scenarios . 6-4 Loading
15、and Unloading Systems Prevention and Detection Measures 6-8 Other Facility Equipment Release Scenarios . 7-3 Other Facility Equipment Prevention and Detection Measures 7-6 Operating System Control Measures Release Scenarios 8-4 Operating System Control Measures Prevention and Detection Measures . 8-
16、5 STD.API/PETRO PUBL 340-ENGL 1997 Bl 0732290 0572058 5bL S EXECUTIVE SUMMARY Preventing releases is an important aspect of day-to-day business for owners and operators of aboveground storage tank (AST) facilities. Over the years, operating practices have been developed and equipment has been design
17、ed to reduce the potential for releases and to protect the environment if a release occurs. Data collected in a 1994 API survey of aboveground tank facilities indicated that the presence of groundwater contamination at aboveground storage tank facilities was mainly attributable to discontinued opera
18、ting practices. Respondents reported significant reductions in releases (during the five-year period preceding the survey) because equipment, operating practices, and standards have improved. The 1994 survey focused on groundwater protection, but current practices at facilities address all facets of
19、 environmental protection. This report compiles information on current industry practices to prevent or detect releases, and to protect groundwater, surface water, and soil in the event of a liquid release. Air emissions are not addressed in this report. Specifically, the report addresses facility t
20、anks, piping, loading/unloading areas, ancillary equipment, as well as facility operating systems - or the human factor. For each of these components, the report provides: e A summary of the potential causes of liquid petroleum releases; e An overview of the procedures and equipment available to ope
21、rators to prevent, detect or provide environmental protection from such releases; and 0 The advantages and disadvantages of various control measures including relative costs, as well as maintenance and operating parameters. Much of the information presented in the document is taken from API standard
22、s and research reports. Additionally, current industry practices and industry examples are included. The report is not intended to provide requirements; rather, it represents a compilation of the various methods that industry uses to prevent and detect releases. Effective operation of facilities and
23、 release prevention involve the evaluation and use of a wide range of control measures. Selection of appropriate measures must be made on a site-specific basis and then tailored to meet the needs of each location. ES- 1 STD.API/PETRC PUBL 340-ENGL 2977 0732270 0572059 4TB Aboveground Storage Tanks T
24、he approach taken by the report is illustrated in Table ES- 1, which gives an overview of types of releases that can occur at facilities and lists some of the available control measures. The table, which is not intended to be comprehensive, shows that multiple methods are available to address each t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- APIPUBL3401997LIQUIDRELEASEPREVENTIONANDDETECTIONMEASURESFORABOVEGROUNDSTORAGEFACILITIES 地面 储存 设施 液体

链接地址:http://www.mydoc123.com/p-399745.html