API MPMS 14.9-2013 Measurement of Natural Gas by Coriolis Meter (Second Edition Available through AGA (American Gas Association) only as AGA Report No 11 See Global Engineering D.pdf
《API MPMS 14.9-2013 Measurement of Natural Gas by Coriolis Meter (Second Edition Available through AGA (American Gas Association) only as AGA Report No 11 See Global Engineering D.pdf》由会员分享,可在线阅读,更多相关《API MPMS 14.9-2013 Measurement of Natural Gas by Coriolis Meter (Second Edition Available through AGA (American Gas Association) only as AGA Report No 11 See Global Engineering D.pdf(172页珍藏版)》请在麦多课文档分享上搜索。
1、 AGA Report No. 11 API MPMS Chapter 14.9 Measurement of Natural Gas by Coriolis Meter Prepared by Transmission Measurement Committee Second Edition, February 2013 AGA Report No. 11 API MPMS Chapter 14.9 Measurement of Natural Gas by Coriolis MeterPrepared by Transmission Measurement CommitteeSecond
2、Edition, February 2013 Copyright 2013 American Gas Association All Rights Reserved Catalog # XQ1301 iiiiiDISCLAIMERANDCOPYRIGHTThe American Gas Associations (AGA) Operations and Engineering Section provides a forum for industry experts to bring their collective knowledge together to improve the stat
3、e of the art in the areas of operating, engineering and technological aspects of producing, gathering, transporting, storing, distributing, measuring and utilizing natural gas.Through its publications, of which this is one, AGA provides for the exchange of information within the natural gas industry
4、 and scientific, trade and governmental organizations. Many AGA publications are prepared or sponsored by an AGA Operations and Engineering Section technical committee. While AGA may administer the process, neither AGA nor the technical committee independently tests, evaluates or verifies the accura
5、cy of any information or the soundness of any judgments contained therein. AGA disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of or r
6、eliance on AGA publications. AGA makes no guaranty or warranty as to the accuracy and completeness of any information published therein. The information contained therein is provided on an “as is” basis and AGA makes no representations or warranties including any expressed or implied warranty of mer
7、chantability or fitness for a particular purpose.In issuing and making this document available, AGA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is AGA undertaking to perform any duty owed by any person or entity to someone else. Anyone us
8、ing this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. AGA has no power, nor does it undertake, to police or enforce compliance with the contents o
9、f this document. Nor does AGA list, certify, test or inspect products, designs or installations for compliance with this document. Any certification or other statement of compliance is solely the responsibility of the certifier or maker of the statement. AGA does not take any position with respect t
10、o the validity of any patent rights asserted in connection with any items that are mentioned in or are the subject of AGA publications, and AGA disclaims liability for the infringement of any patent resulting from the use of or reliance on its publications. Users of these publications are expressly
11、advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, is entirely their own responsibility. Users of this publication should consult applicable federal, state and local laws and regulations. AGA does not, through its publications intend to
12、 urge action that is not in compliance with applicable laws, and its publications may not be construed as doing so. Changes to this document may become necessary from time to time. If changes are believed appropriate by any person or entity, such suggested changes should be communicated to AGA in wr
13、iting and sent to: Operations full name of the document; suggested revisions to the text of the document; the rationale for the suggested revisions; and permission to use the suggested revisions in an amended publication of the document. Copyright 2013, American Gas Association, All Rights Reserved.
14、 ivFOREWORDThis report has been written in the form of a performance-based specification. If this performance-based specification is used, Coriolis meters shall meet or exceed the function, accuracy, and testing requirements specified in this report and designers shall follow the applicable installa
15、tion recommendations. This report is split into two distinct sections the main body of the report and a series of appendices. The main body should be considered normative as it describes working practice when applying and using Coriolis meters to measure natural gas flow. The appendices are informat
16、ive and contain additional material, background and examples of how Coriolis meters are installed and operated.Methods for verifying a meters accuracy and/or applying a Flow Weighted Mean Error (FWME) correction factor to minimize the measurement uncertainty are contained in Appendix A, “Coriolis Ga
17、s Flow Meter Calibration Issues.” Depending on the design, it may be necessary to flow-calibrate each meter on a gas similar to that expected in service. In order to guide the designer in the specification of a Coriolis meter, Appendix B, “Coriolis Meter Data Sheet,” has been provided. As a referenc
18、e for background information on Coriolis natural gas metering, Appendix C, “AGA Engineering Technical Note, XQ0112, Coriolis Flow Measurement for Natural Gas Applications,” is provided. Due to the unique principle of operation and atypical performance characteristics of Coriolis mass flow meters, in
19、 comparison to volumetric flow meters, readers who are not familiar with the technology are encouraged to read the Appendix C prior to applying the general concepts and guidelines of this report. This report offers general criteria for the measurement of natural gas by Coriolis meters. It is the cum
20、ulative result of years of experience of many individuals and organizations acquainted with measuring gas flow rate and/or the practical use of Coriolis meters for gas measurement. Changes to this report may become necessary from time to time. vACKNOWLEDGEMENTSThe revision work of this report was un
21、dertaken by a task group the Transmission Measurement Committee (TMC). The task group was chaired by Angela Floyd who was with ConocoPhillips during the development and finalization of this report. Angela was supported by the vice chair, Karl Stappertwith Micro Motion. A special subcommittee of the
22、task group was formed later to assemble additional technical information, compose the drafts of the revised report for balloting and finally resolve the ballot comments and prepare the final report. The members of the special subcommittee who devoted an extensive amount of their time and deserve spe
23、cial thanks are Kerry Checkwitch, Spectra Energy Transmission Craig Chester, Williams Gas P/L John Daly, GE Sensing Robert DeBoom, Consultant Robert Fallwell, TransCanada P/L Ron Gibson, ONEOK, Inc. Terry Grimley, Southwest Research Institute (SwRI) John Hand, Spectra Energy Transmission Michael Kei
24、lty, Endress + Hauser Flowtec AG Allen Knack, Consumers Energy Brad Massey, Southern Star Central Gas P/L Paul LaNasa, CPL and Associates Stephanie Lane, Micro Motion, Inc. Dannie Mercer, Atmos Energy Corporation Gary McCargar, ONEOK, Inc. Bill Morrow, Telvent Mark Pelkey, National Fuel Gas Supply C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- APIMPMS1492013MEASUREMENTOFNATURALGASBYCORIOLISMETERSECONDEDITIONAVAILABLETHROUGHAGAAMERICANGASASSOCIATIONONLYASAGAREPORTNO11SEEGLOBALENGINEERINGDPDF

链接地址:http://www.mydoc123.com/p-399539.html