BS PD ISO TR 16379-2014 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging《组织工程医疗产品 用DT(扩散张量)-MR成像对关节软骨各向异性组织的评.pdf
《BS PD ISO TR 16379-2014 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging《组织工程医疗产品 用DT(扩散张量)-MR成像对关节软骨各向异性组织的评.pdf》由会员分享,可在线阅读,更多相关《BS PD ISO TR 16379-2014 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging《组织工程医疗产品 用DT(扩散张量)-MR成像对关节软骨各向异性组织的评.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication PD ISO/TR 16379:2014 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR ImagingPD ISO/TR 16379:2014 PUBLISHED DOCUMENT National foreword This Published Document is the UK implementation of ISO/TR 1637
2、9:2014. The UK participation in its preparation was entrusted to Technical Committee RGM/1, Regenerative medicine. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contrac
3、t. Users are responsible for its correct application. The British Standards Institution 2014. Published by BSI Standards Limited 2014 ISBN 978 0 580 82564 4 ICS 11.040.40 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the
4、 authority of the Standards Policy and Strategy Committee on 31 May 2014. Amendments/corrigenda issued since publication Date T e x t a f f e c t e dPD ISO/TR 16379:2014 ISO 2014 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)
5、-MR Imaging Produits mdicaux base de tissus valuation de la structure anisotrope du cartilage articulaire en utilisant limagerie en tenseur de diffusion (IRM-TD) TECHNICAL REPORT ISO/TR 16379 First edition 2014-03-01 Reference number ISO/TR 16379:2014(E)PD ISO/TR 16379:2014ISO/TR 16379:2014(E)ii ISO
6、 2014 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2014 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intrane
7、t, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Publi
8、shed in SwitzerlandPD ISO/TR 16379:2014ISO/TR 16379:2014(E) ISO 2014 All rights reserved iii Contents Page Foreword iv Introduction v 1 Scope . 1 2 T erms and definitions . 1 3 Principle 3 4 Diffusion tensor magnetic resonance imaging (DT-MRI) data observation in articular cartilage 3 4.1 DT-MRI mea
9、surement process 3 4.2 Notes on setting of DT-MRI imaging parameters for articular cartilage . 4 4.3 Measurement indices for structural evaluation of articular cartilage by DT-MRI 5 Annex A (informative) Measurement Results 10 Bibliography .23PD ISO/TR 16379:2014ISO/TR 16379:2014(E) Foreword ISO (th
10、e International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committ
11、ee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechn
12、ical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted
13、in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights
14、. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this document is information given for the convenience of users and does not constitut
15、e an endorsement. For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information The commi
16、ttee responsible for this document is ISO/TC 150, Implants for Surgery, Subcommittee SC 7, Tissue-engineered Medical Products.iv ISO 2014 All rights reservedPD ISO/TR 16379:2014ISO/TR 16379:2014(E) Introduction Structural evaluation of articular cartilage with conventional diagnostic technologies is
17、 challenging, and Nihon University has developed technologies (see Reference 1) and collected relevant data for in vivo evaluation of articular cartilage structure by means of diffusion tensor magnetic resonance imaging (DT-MRI) using 1,5 Tesla or 3 Tesla MRI equipment employed for treatment in hosp
18、ital settings. These data are released in this Technical Report prepared for reference in treatment settings. This work is part of “Development of Cartilage Observation and Evaluation Technologies for Regenerative Medicine Processes”, an activity managed by the University under “Development of Evalu
19、ation Technology for Early Introduction of Regenerative Medicine”, a project contracted by the New Energy and Industrial Technology Development Organization (NEDO) to the National Institute of Advanced Industrial Science and Technology (AIST) and its Technology Research Association of Medical Welfar
20、e Apparatus. ISO 2014 All rights reserved vPD ISO/TR 16379:2014PD ISO/TR 16379:2014Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging 1 Scope This Technical Report has been prepared for evaluation of therapeutic course
21、s for articular cartilage disease and summarizes results from structural evaluation of knee joint cartilage by diffusion tensor imaging, an MRI applied technology allowing non-invasive observation of soft tissue morphology in vivo. This Technical Report is intended for use in areas such as regenerat
22、ive medicine for knee joint cartilage disease. After in vivo transplant of cartilage cells or tissue as a regenerative treatment, longitudinal diagnosis is needed to assess regeneration as articular cartilage, but arthroscopes used primarily for this purpose are invasive and also do not allow evalua
23、tion of structure by simple observation of surfacial characteristics. Radiography and CT do not visualize articular cartilage and also entail the problem of exposure. Collagen fibres, the primary component of articular cartilage, have a surfacial layer parallel to the articular surface to serve a lu
24、bricating function for the articular surface, a middle layer with a randomized structure to distribute loads, and deep layers oriented vertically to support loads. The anisotropy of this three-layer structure is a characteristic feature of hyaline cartilage structures and a mechanism demonstrating a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDISOTR163792014TISSUEENGINEEREDMEDICALPRODUCTSEVALUATIONOFANISOTROPICSTRUCTUREOFARTICULARCARTILAGEUSINGDTDIFFUSIONTENSORMRIMAGING

链接地址:http://www.mydoc123.com/p-398766.html