BS PD IEC TS 62257-9-2-2016 Recommendations for renewable energy and hybrid systems for rural electrification Integrated systems Microgrids《农村电气化用可再生能源和混合系统的建议 综合系统 微型电网》.pdf
《BS PD IEC TS 62257-9-2-2016 Recommendations for renewable energy and hybrid systems for rural electrification Integrated systems Microgrids《农村电气化用可再生能源和混合系统的建议 综合系统 微型电网》.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TS 62257-9-2-2016 Recommendations for renewable energy and hybrid systems for rural electrification Integrated systems Microgrids《农村电气化用可再生能源和混合系统的建议 综合系统 微型电网》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、Recommendations for renewable energy and hybrid systems for rural electrification Part 9-2: Integrated systems Microgrids PD IEC/TS 62257-9-2:2016 BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National foreword This Published Document is the UK implementation of I
2、EC/TS 62257-9- 2:2016. It supersedes DD IEC/TS 62257-9-2:2006 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee GEL/82, Photovoltaic Energy Systems. A list of organizations represented on this committee can be obtained on request to its secretary. This
3、publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Published by BSI Standards Limited 2016 ISBN 978 0 580 91980 0 ICS 27.160 Compliance with a British Standard cannot confer im
4、munity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 October 2016. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TS 62257-9-2:2016 IEC TS 62257-9-2 Edition 2.0 2016-
5、09 TECHNICAL SPECIFICATION Recommendations for renewable energy and hybrid systems for rural electrification Part 9-2: Integrated systems Microgrids INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 27.160 ISBN 978-2-8322-3586-7 Registered trademark of the International Electrotechnical Commission Warni
6、ng! Make sure that you obtained this publication from an authorized distributor. colour inside PD IEC/TS 62257-9-2:2016 2 IEC TS 62257-9-2:2016 IEC 2016 CONTENTS FOREWORD. 5 INTRODUCTION . 7 1 Scope 8 2 Normative reference 8 3 Terms and definitions 8 4 General . 10 4.1 Limits of a microgrid 10 4.2 V
7、oltage drops 10 4.3 Composition of a microgrid 10 5 Protection against electric shocks 12 6 Protection against overcurrents 12 7 Selection and erection of equipment. 12 7.1 Equipment installation . 12 7.2 Operational conditions and external influences 12 7.2.1 Ambient temperature 12 7.2.2 Sources of
8、 heat 12 7.2.3 Presence of water 12 7.2.4 Risk of penetration of solid bodies 13 7.2.5 Corrosive or polluting substance presence 13 7.2.6 Mechanical requirements . 13 7.2.7 Equipment and supporting structures 13 7.2.8 Vibration 13 7.2.9 Other mechanical constraints for underground microgrid sections
9、 . 13 7.2.10 Presence of flora, mold or fauna . 14 7.2.11 Solar radiation . 14 7.3 Characteristics of lines 14 7.3.1 General . 14 7.3.2 Installation modes 14 7.3.3 Minimum height of conductors 14 7.3.4 Proximity to other services . 14 7.4 Cables 14 7.5 Poles 15 7.5.1 General . 15 7.5.2 Characteristi
10、cs of poles 15 7.6 Cable anchorage . 17 7.7 Connections and accessories 18 7.7.1 General . 18 7.7.2 Connections between conductors, connections to other equipment 18 7.7.3 Connection points for individual service connections . 18 7.7.4 Connection equipment . 18 7.8 Where poles are used for other pur
11、poses . 19 7.8.1 Public lighting points 19 7.8.2 Telecommunication lines 19 7.9 Isolation and switching 20 7.9.1 Overcurrent protection device . 20 PD IEC/TS 62257-9-2:2016IEC TS 62257-9-2:2016 IEC 2016 3 7.9.2 Isolating devices 21 7.10 Earthing arrangement, protective conductors and protective bond
12、ing conductors 21 8 Verification and acceptance . 22 8.1 General . 22 8.2 Supervision of works . 22 8.3 Verification before commissioning (on site acceptance) 23 8.4 Operation tests . 23 Annex A (informative) Characteristics of cables 24 Annex B (informative) Maximum circuit length 26 Figure 1 Micro
13、grid limits . 10 Figure 2 Microgrid consisting of a single phase feeder 11 Figure 3 Three phase system output, single phase distribution or three phase service provided where needed . 11 Figure 4 Three phase system output, single phase distribution 11 Figure 5 Diagram showing installation of twinned
14、 wooden poles forming an angle . 16 Figure 6 Examples of different pole arrangements 17 Figure 7 Example of an overhead line . 17 Figure 8 Connection mode diagram 19 Figure 9 Microgrid earthing scheme 21 Figure B.1 Maximum lengths as a function of active power (1 phase) for 16 mm 2cable and 6 % volt
15、age drop with loads at end of cable 27 Figure B.2 Maximum lengths as a function of active power (1 phase) for 16 mm 2cable and 6 % voltage drop with loads spread across cable 28 Figure B.3 Maximum lengths as a function of active power (1 phase) for 25 mm 2cable and 6 % voltage drop with loads at end
16、 of cable 29 Figure B.4 Maximum lengths as a function of active power (1 phase) for 25 mm 2cable and 6 % voltage drop with loads spread across cable 30 Figure B.5 Maximum lengths as a function of active power (3 phase) for 35 mm 2cable and 6 % voltage drop with loads at end of cable 31 Figure B.6 Ma
17、ximum lengths as a function of active power (3 phase) for 35 mm 2cable and 6 % voltage drop with loads spread across cable 32 Figure B.7 Maximum lengths as a function of active power (3 phase) for 35 mm 2cable and 3 % voltage drop with loads at end of cable 33 Figure B.8 Maximum lengths as a functio
18、n of active power (3 phase) for 50 mm 2cable and 6 % voltage drop with loads at end of cable 34 Figure B.9 Maximum lengths as a function of active power (3 phase) for 50 mm 2cable and 6 % voltage drop with loads spread across cable 35 Figure B.10 Maximum lengths as a function of active power (3 phas
19、e) for 50 mm 2cable and 3 % voltage drop with loads at end of cable 36 Figure B.11 Maximum lengths as a function of active power (3 phase) for 70 mm 2cable and 6 % voltage drop with loads at end of cable 37 Figure B.12 Maximum lengths as a function of active power (3 phase) for 70 mm 2cable and 6 %
20、voltage drop with loads spread across cable 38 Figure B.13 Maximum lengths as a function of active power (3 phase) for 70 mm 2cable and 3 % voltage drop with loads at end of cable 39 PD IEC/TS 62257-9-2:2016 4 IEC TS 62257-9-2:2016 IEC 2016 Table 1 Maximum values of voltage drops 10 Table 2 Fuse rat
21、ings for protection from short-circuiting in 230 V (and 240 V) a.c. microgrids (overhead lines) . 20 Table 3 Fuse ratings for protection from short-circuiting in 120 V a.c. microgrids (overhead lines) 20 Table 4 Circuit breaker ratings for protection from short-circuiting in microgrids (overhead lin
22、es) 20 Table 5 Characteristics of earthing components 22 Table A.1 Example of characteristics of grid conductors for overhead lines (insulated twisted conductors without carrier neutral) . 24 PD IEC/TS 62257-9-2:2016IEC TS 62257-9-2:2016 IEC 2016 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ RECOMME
23、NDATIONS FOR RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION Part 9-2: Integrated systems Microgrids FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committ
24、ees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Availabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTS62257922016RECOMMENDATIONSFORRENEWABLEENERGYANDHYBRIDSYSTEMSFORRURALELECTRIFICATIONINTEGRATEDSYSTEMSMICROGRIDS

链接地址:http://www.mydoc123.com/p-397789.html