BS PD IEC TS 60079-39-2015 Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation《爆炸性环境 带电子控制火花持续时间限制的本安型系统》.pdf
《BS PD IEC TS 60079-39-2015 Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation《爆炸性环境 带电子控制火花持续时间限制的本安型系统》.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TS 60079-39-2015 Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation《爆炸性环境 带电子控制火花持续时间限制的本安型系统》.pdf(56页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication Explosive atmospheres Part 39: Intrinsically safe systems with electronically controlled spark duration limitation PD IEC/TS 60079-39:2015National foreword This Published Document is the UK implementation of IEC/TS 60079-39:2015. The UK participation in its preparation was
2、entrusted by Technical Committee EXL/31, Equipment for explosive atmospheres, to Sub- committee EXL/31/2, Intrinsically safe apparatus. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary pr
3、ovisions of a contract. Users are responsible for its correct application. The British Standards Institution 2015. Published by BSI Standards Limited 2015 ISBN 978 0 580 81621 5 ICS 29.260.20 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document wa
4、s published under the authority of the Standards Policy and Strategy Committee on 30 June 2015. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TS 60079-39:2015IEC TS 60079-39 Edition 1.0 2015-06 TECHNICAL SPECIFICATION Explosive atmospheres Part 39: Intri
5、nsically safe systems with electronically controlled spark duration limitation INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.260.20 ISBN 978-2-8322-2734-3 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized
6、 distributor. colour inside 2 IEC TS 60079-39:2015 IEC 2015 CONTENTS FOREWORD . 5 INTRODUCTION . 7 1 Scope 8 2 Normative references. 8 3 Definitions . 9 4 Power-i architecture . 10 5 Requirements for Power-i devices 11 5.1 General . 11 5.2 Power-i source 11 5.3 Power-i field device . 13 5.4 Power-i
7、wiring . 14 5.5 Power-i terminator . 15 5.6 Test instruments for Power-i loop check 15 5.7 Power-i application classes . 15 6 System requirements . 16 6.1 Selection of the permissible Power- i current class of the Power-i source . 16 6.2 Verification of a Power-i system . 17 7 Assessment and testing
8、 . 19 7.1 Procedure to define safety-relevant parameters . 19 7.2 Type test . 20 7.3 Routine test 20 8 Marking of Power-i devices 20 8.1 General . 20 8.2 Examples of marking . 20 9 Instructions 21 Annex A (normative) Assessment of Power-i safety parameters 22 A.1 General . 22 A.2 Power-i specific te
9、st equipment . 22 A.2.1 Power-i universal test equipment 22 A.2.2 Power-i dummy load . 23 A.3 Determination of the safety-relevant parameters for Power-i devices and Power-i wiring . 24 A.3.1 General . 24 A.3.2 Safety-relevant parameters for the Power-i source 24 A.3.3 Safety-relevant parameters for
10、 the Power-i field devices . 31 A.3.4 Safety-relevant parameters for Power-i wiring . 34 A.3.5 Safety-relevant parameters for the Power-i terminator . 36 Annex B (informative) Explanation and details of the Power-i basic concept 37 B.1 Physical basics of an ignition . 37 B.2 Output characteristics o
11、f a Power-i source . 39 B.3 Measurement and scientific results as basis for Power- i minimum ignition values . 41 B.3.1 Test setups for the determination of the ignition probability . 41 B.3.2 Result of the spark ignition tests and their implementation in Table 3 43 PD IEC/TS 60079-39:2015IEC TS 600
12、79-39:2015 IEC 2015 3 Annex C (informative) Examples of Power-i devices and systems . 46 C.1 Power-i application for a solenoid valve . 46 C.2 Example of a generally designed Power-i source . 47 C.3 Example of a Power-i field device 47 C.4 Example of a Power-i dummy load . 48 C.5 Example of a Power-
13、i terminator 48 Annex D (informative) Example of interconnection of Power-i devices including Power-i wiring to a Power-i system 50 D.1 Specific aim and given values 50 D.2 Solution example 50 Figure 1 The simplest Power-i architecture . 10 Figure 2 Example of complex Power-i concept architecture .
14、11 Figure 3 Elements of a Power-i source with voltage and current limitation . 12 Figure 4 Example of a universal Power-i field device (basic structure) . 14 Figure 5 Basic assessment procedure for a Power-i system 19 Figure A.1 Basic principle of the Power-i universal test equipment 23 Figure A.2 P
15、ulse output between terminals 3 and 1 of Figure A.1 23 Figure A.3 Basic principle of a Power-i dummy load 24 Figure A.4 Basic principle of the equipment for the determination of the response time t resp-source25 Figure A.5 Example of an oscillogram to determine the response time t resp-source26 Figu
16、re A.6 Test equipment for the determination of the assessment factorAF source(basic principle) 27 Figure A.7 Test equipment for the assessment factor test for Power-i source 28 Figure A.8 Example of an oscillogram from a test of a Power-i source with an assessment factor AF = 8,29 for a break spark
17、29 Figure A.9 Test equipment for transition pulse test of a Power-i source . 30 Figure A.10 Test equipment for the determination of the assessment factor AF field device for Power-i field devices (basic principle) 32 Figure A.11 Test equipment for the transition pulse test of Power-i field devices .
18、 33 Figure A.12 Evaluation parameter of test pulse U pulsefor transition pulse test . 34 Figure A.13 Test equipment for the determination of the response time of the Power- i trunk t resp-trunk(basic principle) 35 Figure B.1 Example of a typical trace of a break spark supplied with a linearly limite
19、d source 38 Figure B.2 Example of a typical trace of a break spark limited by a Power-i source . 38 Figure B.3 Example of output set of characteristic curves of a Power-i source during load connection 40 Figure B.4 Basic principle of a Power-i power source for the voltage threshold return mode 41 Fi
20、gure B.5 Example of output set of characteristic curves of a Power-i source in the case of a failure 41 Figure B.6 Test setup with STA for break sparks 42 Figure B.7 Test setup with STA for make sparks . 42 Figure B.8 Power-i ignition values for voltage class 24V (24 VDC) 43 Figure B.9 Power-i ignit
21、ion values for voltage class 32V (32 VDC) 44 PD IEC/TS 60079-39:2015 4 IEC TS 60079-39:2015 IEC 2015 Figure B.10 Power-i ignition values for voltage class 40V (40 VDC) 44 Figure B.11 Ignition energy in relation to the used hydrogen percentage in the gas mixtures . 45 Figure C.1 Simple solenoid valve
22、 Power-i application (example) . 46 Figure C.2 Example of a generally styled Power-i field device . 47 Figure C.3 Example of a V-limitation unit (level of protection “ib”) . 48 Figure C.4 Example of a Power-i dummy load . 48 Figure C.5 Example of a Power-i terminator 49 Table 1 Definition of Power-i
23、 voltage classes 16 Table 2 Definition of Power-i current classes 16 Table 3 Permitted combinations of Power-i application classes for Power-i sources as a function of the system response time for all Groups (n.a. = not allowed) . 17 Table 4 Power-i current classes of Power-i field devices or Power-
24、i terminators matching the current class of the Power-i source . 18 Table 5 Relevance for Power-i test procedures . 20 PD IEC/TS 60079-39:2015IEC TS 60079-39:2015 IEC 2015 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ EXPLOSIVE ATMOSPHERES Part 39: Intrinsically safe systems with electronically cont
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTS60079392015EXPLOSIVEATMOSPHERESINTRINSICALLYSAFESYSTEMSWITHELECTRONICALLYCONTROLLEDSPARKDURATIONLIMITATION

链接地址:http://www.mydoc123.com/p-397755.html