BS PD IEC TR 61282-14-2016 Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants《光纤通信系统设计指南 纤维植物中衰减.pdf
《BS PD IEC TR 61282-14-2016 Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants《光纤通信系统设计指南 纤维植物中衰减.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TR 61282-14-2016 Fibre optic communication system design guides Determination of the uncertainties of attenuation measurements in fibre plants《光纤通信系统设计指南 纤维植物中衰减.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、Fibre optic communication system design guides Part 14: Determination of the uncertainties of attenuation measurements in fibre plants PD IEC/TR 61282-14:2016 Incorporating corrigendum April 2016 BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National foreword T h
2、i s P u b l i s h e d D o c u m e n t i s t h e U K i m p l e m e n t a t i o n o f I E C / T R 61282-14:2016, incorporating corrigendum April 2016. The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/3, Fibre optic systems and ac
3、tive devices. A list of organizations represented on this subcommittee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Publ
4、ished by BSI Standards Limited 2016 ISBN 978 0 580 94415 4 ICS 33.180.01 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 January 2016. Amendments/corrigend
5、a issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TR 61282-14:2016 31 May 2016 Implementation of IEC corrigendum April 2016: Table C.1 updated IEC TR 61282-14 Edition 1.0 2016-01 TECHNICAL REPORT Fibre optic communication system design guides Part 14: Determination of the uncer
6、tainties of attenuation measurements in fibre plants INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 33.180.01 ISBN 978-2-8322-3111-1 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colour insid
7、e PD IEC/TR 61282-14:2016 2 IEC TR 61282-14:2016 IEC 2016 CONTENTS FOREWORD . 5 INTRODUCTION . 7 1 Scope 8 2 Normative references 8 3 Terms, definitions and abbreviations . 8 3.1 Terms and definitions 8 3.2 Abbreviations 10 4 Overview of uncertainty . 10 4.1 What is uncertainty? . 10 4.2 Origin of u
8、ncertainties . 10 4.3 What may not be considered as uncertainty? 10 5 Fibre cabling attenuation measurement . 11 5.1 Measurement methods 11 5.2 Sources of uncertainty to be considered . 11 5.2.1 Analysis . 11 5.2.2 Uncertainties due to the environment . 14 5.2.3 Uncertainties due to operator skills
9、14 5.2.4 Uncertainties due to measurement methods 14 5.2.5 Uncertainties due to measuring instruments 14 5.2.6 Uncertainties due to the setup . 16 5.2.7 Uncertainties due to cabling. 16 6 Uncertainties estimation 17 6.1 Measurement model 17 6.2 Accumulation of uncertainties . 18 7 General representa
10、tion of the equation using sensitivity coefficients 19 8 Calculation 22 8.1 Combined standard uncertainty . 22 8.2 Expanded uncertainty . 22 8.3 Determination of the coverage factor k 22 8.3.1 General approach 22 8.3.2 Discussion . 22 8.3.3 Typical values of degree of freedom 23 Annex A (normative)
11、Mathematical basis . 24 A.1 General . 24 A.2 Type A evaluation of uncertainty . 24 A.3 Type B evaluation of uncertainty . 24 A.4 Determining the combined standard uncertainty 25 A.5 Reporting 26 Annex B (informative) Measurement methods 27 B.1 Measurement methods as per IEC 61280-4-1 and 61280-4-2 2
12、7 B.1.1 General . 27 B.1.2 Measurement configuration 27 B.1.3 One-cord reference configuration 27 B.1.4 Two-cord reference configuration 28 B.1.5 Three-cord reference configuration 28 PD IEC/TR 61282-14:2016IEC TR 61282-14:2016 IEC 2016 3 B.2 Measurement methods as per ISO/IEC 14763-3:2014 . 28 B.2.
13、1 General . 28 B.2.2 Channels . 29 B.2.3 Links 30 Annex C (normative) Uncertainties evaluation 31 C.1 Type A uncertainties . 31 C.1.1 General . 31 C.1.2 Evaluation of optical source instability and associated uncertainties 31 C.2 Type B uncertainties . 31 C.2.1 General . 31 C.2.2 Evaluation of the p
14、ower meter noise 31 C.2.3 Elements to be considered for power meter stability analysis . 32 C.2.4 Evaluation of the centre wavelength dependence 32 C.2.5 Spectral width dependence 34 C.2.6 Evaluation of the uncertainties due to MM launch conditions . 34 C.2.7 Evaluation of the PDL 35 C.2.8 Uncertain
15、ty of absolute power measurement . 36 Annex D (normative) Typical values of uncertainties 37 Annex E (informative) Linear to dB scale conversion of uncertainties . 38 E.1 Definition of decibel 38 E.2 Conversion of relative uncertainties 38 Bibliography 39 Figure 1 Fish bone analysis . 13 Figure 2 Me
16、asurement model . 17 Figure B.1 Measurement configuration . 27 Figure B.2 One-cord reference measurement . 27 Figure B.3 Two-cord reference measurement . 28 Figure B.4 Three-cord reference measurement 28 Figure B.5 Measurement on channel 29 Figure B.6 Channel reference measurement 29 Figure B.7 Link
17、 measurement configuration . 30 Figure B.8 Link reference measurement . 30 Figure C.1 Typical spectral response of a fibre 33 Figure C.2 Uncertainties due to the launch conditions for a given loss . 35 Table 1 Source of uncertainty (raw list) 11 Table 2 Uncertainties due to measuring instruments 15
18、Table 3 Uncertainties due to the setup . 16 Table 4 Uncertainties due to cabling 16 Table 5 Sensitivity coefficients for IEC 61280-4-1 and IEC 61280-4-2 methods 20 Table 6 Sensitivity coefficients for ISO/IEC 14763-3:2014 methods 21 Table 7 Values of k 95for different values of n 23 Table 8 Typical
19、values of n i. 23 Table C.1 Spectral attenuation coefficients 33 PD IEC/TR 61282-14:2016 4 IEC TR 61282-14:2016 IEC 2016 Table C.2 Sensitivity coefficients . 33 Table D.1 Typical values of uncertainties . 37 PD IEC/TR 61282-14:2016IEC TR 61282-14:2016 IEC 2016 5 INTERNATIONAL ELECTROTECHNICAL COMMIS
20、SION _ FIBRE OPTIC COMMUNICATION SYSTEM DESIGN GUIDES Part 14: Determination of the uncertainties of attenuation measurements in fibre plants FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical commi
21、ttees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical
22、 Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental
23、and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agree
24、ments of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTR61282142016FIBREOPTICCOMMUNICATIONSYSTEMDESIGNGUIDESDETERMINATIONOFTHEUNCERTAINTIESOFATTENUATIONMEASUREMENTSINFIBREPLANTS

链接地址:http://www.mydoc123.com/p-397663.html