BS PD IEC TR 60601-4-2-2016 Medical electrical equipment Guidance and interpretation Electromagnetic immunity performance of medical electrical equipment and medical elec.pdf
《BS PD IEC TR 60601-4-2-2016 Medical electrical equipment Guidance and interpretation Electromagnetic immunity performance of medical electrical equipment and medical elec.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TR 60601-4-2-2016 Medical electrical equipment Guidance and interpretation Electromagnetic immunity performance of medical electrical equipment and medical elec.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、Medical electrical equipment Part 4-2: Guidance and interpretation Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems PD IEC/TR 60601-4-2:2016 BSI Standards PublicationNational foreword This Published Document is the UK implementation of IEC/TR 60601
2、-4-2:2016. The UK participation in its preparation was entrusted by Technical Committee CH/62, Electrical Equipment in Medical Practice, to Subcommittee CH/62/1, Common aspects of Electrical Equipment used in Medical Practice. A list of organizations represented on this committee can be obtained on
3、request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Published by BSI Standards Limited 2016 ISBN 978 0 580 88577 8 ICS 11.040.01; 33.100.20 Compli
4、ance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 May 2016. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TR 60601-4-
5、2:2016 IEC TR 60601-4-2 Edition 1.0 2016-05 TECHNICAL REPORT Medical electrical equipment Part 4-2: Guidance and interpretation Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 11.040.01; 33.100.20 ISBN
6、 978-2-8322-3414-3 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colour inside PD IEC/TR 60601-4-2:2016 2 IEC TR 60601-4-2:2016 IEC 2016 CONTENTS FOREWORD . 5 INTRODUCTION . 8 0.1 * General
7、8 0.2 Purpose of this document 8 0.3 How to use this document . 8 0.4 IMMUNITY TEST LEVELS 9 1 Scope and object . 10 1.1 Scope . 10 1.2 Object . 10 2 Normative references. 10 3 Terms and definitions 11 4 General recommendations . 15 4.1 Concurrent and sequential testing . 15 4.2 General test conditi
8、ons 15 4.2.1 Configurations . 15 4.2.2 Artificial hand . 15 4.2.3 Power input voltages and frequencies . 16 5 ME EQUIPMENT and ME SYSTEMS identification, marking and documents 17 5.1 Marking on the outside of ME EQUIPMENT or ME EQUIPMENT parts for which the connector testing exemption specified in 8
9、.13.2 c) is used . 17 5.2 ACCOMPANYING DOCUMENTS 17 5.2.1 General . 17 5.2.2 Instructions for use 17 5.2.3 Requirements applicable to ME EQUIPMENT and ME SYSTEMS for which the connector testing exemption specified in 8.13.2 c) is used . 17 5.2.4 * Technical description . 17 6 Documentation of the te
10、sts 18 6.1 Test plan . 18 6.2 Test report 19 7 * EMISSIONS . 19 8 IMMUNITY recommendations 19 8.1 General . 19 8.2 PATIENT physiological simulation 20 8.3 Termination of PATIENT-COUPLED parts . 21 8.4 HAND-HELD ME EQUIPMENT and parts intended to be HAND-HELD . 21 8.5 Subsystems 21 8.6 PERMANENTLY IN
11、STALLED LARGE ME EQUIPMENT and LARGE ME SYSTEMS . 21 8.7 Operating modes . 22 8.8 Non-ME EQUIPMENT 22 8.9 * Environments of INTENDED USE 22 8.10 * Performance criteria . 23 8.11 * IMMUNITY TEST LEVELS 23 8.12 * IMMUNITY to proximity fields from RF wireless communications equipment 30 8.13 * ESD test
12、ing of connectors . 31 8.13.1 Application of ESD to connectors . 31 8.13.2 Exclusions . 32 PD IEC/TR 60601-4-2:2016IEC TR 60601-4-2:2016 IEC 2016 3 9 Test report. 33 Annex A (informative) General guidance and rationale 35 Annex B (informative) Guide to labelling recommendations . 40 B.1 ACCOMPANYING
13、 DOCUMENTS, instructions for use . 40 B.2 ACCOMPANYING DOCUMENTS, technical description . 40 Annex C (informative) Determination of IMMUNITY TEST LEVELS for SPECIAL ENVIRONMENTS 41 C.1 General . 41 C.2 EM DISTURBANCE level determination . 42 C.3 Assessment of EM DISTURBANCE sources 42 C.4 Test metho
14、ds 42 C.5 Test plan . 42 C.6 Examples of mitigations and special conditions 43 Annex D (informative) Identification of specific IMMUNITY performance criteria . 44 D.1 General . 44 D.2 IMMUNITY performance criteria principles 44 D.2.1 General . 44 D.2.2 IMMUNITY performance criteria for non-ME EQUIPM
15、ENT used in an ME SYSTEM . 44 D.2.3 IMMUNITY performance criteria determination . 44 D.3 IMMUNITY performance criteria examples 44 D.3.1 General examples 44 D.3.2 Example of immunity performance criteria for a radiological table system . 46 D.3.3 Example of immunity performance criteria for ultrason
16、ic diagnostic equipment 46 Annex E (informative) Performance criteria specified by IEC 61000-6-x generic EMC standards . 48 Annex F (informative) Mapping between this document and the elements of IEC 60601-1-2:2014 49 Bibliography . 54 Index of defined terms used in this technical report . 56 Figure
17、 1 RC element of the artificial hand . 16 Figure 2 * PORTS of ME EQUIPMENT and ME SYSTEMS . 20 Figure 3 Examples of environments (locations) of INTENDED USE 25 Table 1 Recommended minimum test plan (1 of 2) 18 Table 2 * ENCLOSURE PORT . 26 Table 3 * Input AC power PORT (1 of 2) . 26 Table 4 Input DC
18、 power PORT . 28 Table 5 * PATIENT COUPLING PORT . 29 Table 6 SIGNAL INPUT/OUTPUT PARTS PORT . 30 Table 7 Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment . 31 Table 8 Parts of connectors to be tested for ESD, based on the connector shell and cover material . 3
19、2 Table 9 * Testing of connectors and pins while connected and disconnected . 32 PD IEC/TR 60601-4-2:2016 4 IEC TR 60601-4-2:2016 IEC 2016 Table 10 Test report minimum contents (1 of 2) 33 Table A.1 Assumptions used in determining IMMUNITY TEST LEVELS specified in Table 7 (1 of 2) . 38 Table B.1 ACC
20、OMPANYING DOCUMENTS, instructions for use 40 Table B.2 ACCOMPANYING DOCUMENTS, technical description 40 Table C.1 Examples of adjusted IMMUNITY TEST LEVELS due to mitigations or special conditions . 43 Table D.1 Example of IMMUNITY performance criteria for a radiological table and gantry system . 46
21、 Table D.2 Example of IMMUNITY performance criteria for ULTRASONIC DIAGNOSTIC EQUIPMENT 47 Table F.1 Mapping between the elements of IEC TR 60601-4-2 and IEC 60601-1- 2:2014 (1 of 5) 49 PD IEC/TR 60601-4-2:2016IEC TR 60601-4-2:2016 IEC 2016 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ MEDICAL ELECT
22、RICAL EQUIPMENT Part 4-2: Guidance and interpretation Electromagnetic immunity: performance of medical electrical equipment and medical electrical systems FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrote
23、chnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specificatio
24、ns, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTR60601422016MEDICALELECTRICALEQUIPMENTGUIDANCEANDINTERPRETATIONELECTROMAGNETICIMMUNITYPERFORMANCEOFMEDICALELECTRICALEQUIPMENTANDMEDICALELECPDF

链接地址:http://www.mydoc123.com/p-397653.html