BS PD CEN TS 16976-2016 Ambient air Determination of the particle number concentration of atmospheric aerosol《环境空气 测定大气气溶胶的颗粒数量浓度》.pdf
《BS PD CEN TS 16976-2016 Ambient air Determination of the particle number concentration of atmospheric aerosol《环境空气 测定大气气溶胶的颗粒数量浓度》.pdf》由会员分享,可在线阅读,更多相关《BS PD CEN TS 16976-2016 Ambient air Determination of the particle number concentration of atmospheric aerosol《环境空气 测定大气气溶胶的颗粒数量浓度》.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、PD CEN/TS 16976:2016 Ambient air Determination of the particle number concentration of atmospheric aerosol BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06PD CEN/TS 16976:2016 PUBLISHED DOCUMENT National foreword This Published Document is the UK implementation of C
2、EN/TS 16976:2016. The UK participation in its preparation was entrusted to Technical Committee EH/2/3, Ambient atmospheres. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of
3、a contract. Users are responsible for its correct application. The British Standards Institution 2016. Published by BSI Standards Limited 2016 ISBN 978 0 580 90926 9 ICS 13.040.20 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published
4、under the authority of the Standards Policy and Strategy Committee on 31 August 2016. Amendments/corrigenda issued since publication Date T e x t a f f e c t e dPD CEN/TS 16976:2016TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16976 August 2016 ICS 13.040.20 English
5、Version Ambient air - Determination of the particle number concentration of atmospheric aerosol Air ambiant - Dtermination de la concentration en nombre de particules de larosol atmosphrique Auenluft - Bestimmung der Partikelanzahlkonzentration des atmosphrischen Aerosols This Technical Specificatio
6、n (CEN/TS) was approved by CEN on 26 June 2016 for provisional application. The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their comments, particularly on the question whether the CEN/TS can be converted into
7、a European Standard. CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS) until
8、the final decision about the possible conversion of the CEN/TS into an EN is reached. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Icel
9、and, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Manag
10、ement Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TS 16976:2016 EPD CEN/TS 16976:2016 CEN/TS 16976:2016 (E) 2 Contents Page European Foreword 5 Introduction 6 1 Scope 7 2 Normativ
11、e references 7 3 Terms and definitions . 7 4 Atmospheric aerosol 8 5 Description of the method . 9 5.1 Sampling and conditioning 9 5.1.1 Sampling . 9 5.1.2 Drying . 10 5.1.3 Dilution 11 5.2 Determination of the number concentration with a CPC 11 5.2.1 Condensation growth 11 5.2.2 Optical detection 1
12、3 6 CPC performance criteria and test procedures . 14 6.1 General . 14 6.2 General requirements of the CPC . 14 6.3 Test conditions 15 6.4 Performance characteristics and criteria . 15 6.5 Test procedures 16 6.5.1 Inlet flow rate accuracy 16 6.5.2 Number concentration measurement range 16 6.5.3 Numb
13、er concentration detection limit . 16 6.5.4 Linearity and slope of response 16 6.5.5 Detection efficiency curve at low particle size 17 6.5.6 Upper particle size detection limit 17 6.5.7 Zero count rate 17 6.5.8 Response time . 17 6.5.9 Dependence of flow rate on supply voltage 17 6.5.10 Accuracy of
14、 temperature and pressure sensor calibration 18 6.5.11 Effect of failure of mains voltage 18 7 Performance criteria and test procedures for the sampling and conditioning system 18 7.1 General requirements 18 7.2 Performance characteristics and criteria . 18 7.3 Diffusion losses . 19 7.4 Relative hum
15、idity . 19 7.5 Dilution factor . 19 7.6 Primary sampling flow . 19 8 Measurement procedure . 20 8.1 Measurement planning 20 8.2 Environmental operating conditions 20 8.3 Initial installation 20 8.4 Initial checks on site 20 PD CEN/TS 16976:2016 CEN/TS 16976:2016 (E) 3 8.5 Data processing and reporti
16、ng 21 9 Quality control, quality assurance and measurement uncertainty 21 9.1 General 21 9.2 Frequency of calibrations, checks and maintenance . 21 9.2.1 General 21 9.2.2 Maintenance of CPC 22 9.2.3 Calibration of CPC plateau region and linearity 22 9.2.4 Determination of CPC low size cut-off . 22 9
17、.2.5 CPC zero check . 22 9.2.6 Number concentration check . 23 9.2.7 CPC flow rate calibration 23 9.2.8 Temperature and pressure sensor calibration 23 9.2.9 CPC internal diagnostics . 23 9.2.10 Sample system maintenance 23 9.2.11 Relative humidity sensor . 23 9.2.12 Dilution factor (where applicable
18、) . 23 9.2.13 Leak check . 23 9.3 Measurement uncertainty . 24 9.3.1 General 24 9.3.2 CPC plateau detection efficiency . 24 9.3.3 CPC detection efficiency drift 24 9.3.4 Flow determination . 25 9.3.5 Correction to standard temperature and pressure 25 9.3.6 Sampling losses due to diffusion to walls .
19、 25 9.3.7 Dilution factor (where applicable) . 25 9.3.8 Calculation of overall uncertainty 25 Annex A (normative) Determination of diffusion losses in sampling lines 27 Annex B (informative) Example of the calculation of diffusion losses in a sampling system 29 B.1 Description of the sampling system
20、 . 29 B.2 Air properties and diffusion coefficient . 30 B.3 Losses in the primary sampling tube . 30 B.4 Losses in the secondary sampling tube and the dryer 31 B.5 Overall sampling losses 31 Annex C (informative) Data reporting 32 C.1 Motivation . 32 C.2 Level 0 (annotated raw data) . 32 C.3 Level 1
21、 (data processed to final physical property, potential corrections applied, original temporal resolution) . 33 C.4 Level 2 (hourly averages, including measures of variability) 33 C.5 GAW WDCA Condensation Particle Counter Level 0 (raw data) file format example (system without sample dilution): 35 C.
22、6 Line-by-line explanations: . 35 Annex D (informative) Uncertainty calculation (example) 47 D.1 General 47 D.2 CPC plateau detection efficiency . 47 PD CEN/TS 16976:2016 CEN/TS 16976:2016 (E) 4 D.3 CPC detection efficiency drift . 47 D.4 Flow determination . 47 D.5 Correction to standard temperatur
23、e and pressure . 47 D.6 Sampling losses due to diffusion to walls 47 D.7 Dilution factor (where applicable) 48 D.8 Calculation of overall uncertainty 48 Annex E (informative) Atmospheric aerosols in Europe 49 E.1 General . 49 E.2 Mean concentrations 49 E.3 Examples of measurements 50 Annex F (inform
24、ative) Dilution systems . 53 F.1 Background 53 F.2 Criteria for dilution systems 53 F.3 Operation principles of dilution systems 53 F.3.1 General . 53 F.3.2 Dilution systems with partial flow filtration 54 F.3.3 Dilution systems with external clean air supply 54 Annex G (informative) Laminar flow 56
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCENTS169762016AMBIENTAIRDETERMINATIONOFTHEPARTICLENUMBERCONCENTRATIONOFATMOSPHERICAEROSOL 环境 空气 测定

链接地址:http://www.mydoc123.com/p-397533.html