BS PD CEN TR 16676-2014 Energy losses by industrial door《工业门的能量损失》.pdf
《BS PD CEN TR 16676-2014 Energy losses by industrial door《工业门的能量损失》.pdf》由会员分享,可在线阅读,更多相关《BS PD CEN TR 16676-2014 Energy losses by industrial door《工业门的能量损失》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication PD CEN/TR 16676:2014 Energy losses by industrial doorPD CEN/TR 16676:2014 PUBLISHED DOCUMENT National foreword This Published Document is the UK implementation of CEN/TR 16676:2014. The UK participation in its preparation was entrusted to Technical Committee B/538/5, Indust
2、rial and commercial garage doors and gates. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Stand
3、ards Institution 2014. Published by BSI Standards Limited 2014 ISBN 978 0 580 83958 0 ICS 91.060.50 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 Novembe
4、r 2014. Amendments issued since publication Date Text affectedPD CEN/TR 16676:2014TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 16676 October 2014 ICS 91.060.50 English Version Energy losses by industrial door Perte dnergie par les portes industrielles Energieverluste durch Industrie
5、tore This Technical Report was approved by CEN on 28 July 2014. It has been drawn up by the Technical Committee CEN/TC 33. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, F
6、rance, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES
7、 KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TR 16676:2014 EPD CEN/TR 16676:2014 CEN/TR 16676:2014 (E) 2 Contents Page Foreword 3 Introdu
8、ction .4 1 Scope 5 2 Normative references 5 3 Simplified calculation basis 5 3.1 Heat transmission with closed door by temperature difference 5 3.2 Air leakage with closed door by wind .6 3.3 Air leakage with closed door by chimney .7 3.4 Infiltration with door open (by wind)8 4 Results . 10 4.1 Gen
9、eral . 10 4.2 Local/metrological data 10 4.3 Building/doors data (dimensions). 11 4.4 Building data (intended use) . 11 5 Results for heat transmission . 13 6 Results for air leakage by wind . 13 7 Results for air leakage by chimney effect 14 8 Infiltration (open door) . 15 9 Summary 17 PD CEN/TR 16
10、676:2014 CEN/TR 16676:2014 (E) 3 Foreword This document (CEN/TR 16676:2014) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. Attention is drawn to the possibility that some of the elements
11、 of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. PD CEN/TR 16676:2014 CEN/TR 16676:2014 (E) 4 Introduction The calculation method in EN 12428 gives a U-value in W/m 2 K for thermal resistance of an
12、industrial door used for access of vehicles accompanied by pedestrians. With a view to energy efficiency (energy saving) it should be remembered, however, that this performance is only achieved when the door is closed. In practice the evidence shows that doors are left open for longer periods than i
13、s perhaps necessary or acceptable. Therefore, it is difficult to see how reducing U-values can improve energy efficiency without radical changes in work place practices or operation mode of the door. In keeping with the whole building approach mandated by the EPBD 1 )building designers should be wor
14、king on a whole building principle rather than an elemental basis which results in a beneficial evaluation of those factors in the construction of the building envelope that contribute significantly to energy conservation in the buildings use. Therefore, it is important that building designers and s
15、pecification writers should seek to: set achievable values for products calculated in accordance with EN 13241-1; consider awareness of the classification possibilities and the availability and need to implement appropriate technologies; consider specifying improved power operated doors specificatio
16、n including appropriate control systems; consider changes to supporting constructions (e.g. lobbies, screens); consider the use of double doors (e.g. insulated external doors, rapid acting internal doors for operational use). There is a common misconception that energy conservation is best achieved
17、(only) through U-value improvements. Due to the nonlinear shape of the U-value/thickness graph there is a danger of achieving diminishing returns from additional thickness of doors. Up to the present time, for the U-values commonly specified for construction in the EU, there has been an approximatel
18、y linear relationship but as the move to seek lower U- values continues this is no longer the case. Concern has been expressed that much of this good work is wasted as long as the practice of leaving doors open for unnecessarily long periods prevails. Therefore, a study with a simplified calculation
19、 basis has been undertaken by CEN/TC 33/WG 5 relating to the energy losses through doors. This Technical Report does not replace the requirements of EN 13241-1 regarding EN 12428. For the purpose of this Technical Report the term “door” and/or “doorset” is used as a general term for “industrial door
20、”. 1) Energy Performance of Buildings Directive (Directive 2002/91/EC). PD CEN/TR 16676:2014 CEN/TR 16676:2014 (E) 5 1 Scope This Technical Report gives simplified calculation relating to the energy losses through doors taking into account: heat transmission with closed door by temperature differenc
21、e, air leakage through a closed door due to wind, air leakage through a closed door due to a chimney effect, and air infiltration with a door open (due to wind). 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for
22、 its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12428, Industrial, commercial and garage doors - Thermal transmittance - Requirements for the calculation EN 13241-1, I
23、ndustrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics 3 Simplified calculation basis 3.1 Heat transmission with closed door by temperature difference Heat transmission coefficient U in W/m 2 K is measured by no
24、tified bodies and calculated per door configuration (according to EN 13241-1). Outside temperature is taken out of Table 1. Heat transmission is then calculated with: ) ( o i t T T U A H = where H tis the power losses by heat transmission, in watts (W); A is the area of exposed surface, in square me
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCENTR166762014ENERGYLOSSESBYINDUSTRIALDOOR 工业门 能量 损失 PDF

链接地址:http://www.mydoc123.com/p-397369.html