《ISO 805-1976 Aluminium oxide primarily used for the production of aluminium Determination of iron content 1 10- Phenanthroline photometric method《主要用于铝生产的氧化铝 铁含.pdf》由会员分享,可在线阅读,更多相关《ISO 805-1976 Aluminium oxide primarily used for the production of aluminium Determination of iron content 1 10- Phenanthroline photometric method《主要用于铝生产的氧化铝 铁含.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL STANDARD 805 INTERNATIONAL ORGANlZATlON FOR STANDARDlLATlON .,r.X;, HAPO;IHAR OPI AHI13AUMII nO CTAH;IAPTM3AUMM .OAGANISATION INTERNATIONALE DE NORMALISATON Aluminium oxide primarily used for the production of aluminium - Determination of iron content - I,1 0-Phenanthroline photometric
2、 method Oxyde dbluminium principalement utilisti pour la production de ILluminium - Dosage du fer - MCthode photometrique ij la phPnan throline- 1,lO First edition - 1976-09-15 Y 1, ( : .: , *Q / ,f i v;:I; r3 .L, ,$, 8 -4 :,-: 1 ), .1 , ,L. y 1 1 I,;:,$ j, b ( i; ,3 :A( : ; ( 3; . . ” s 1 , *a UDC
3、661.862.22 : 546.72 : 543.42 Ref. No. IS0 805-1976 (E) Descriptors : aluminium oxide, chemical analysis, determination of content, iron, spectrophotometric analysis. Price based on 4 pages Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo
4、 reproduction or networking permitted without license from IHS-,-,-FOREWORD IS0 (the international Organization for Standardization) is a worldwide federation of national standards institutes (IS0 Member Bodies). The work of developing International Standards is carried out through IS0 Technical Com
5、mittees. Every Member Body interested in a subject for which a Technical Committee has been set up has the right to be represented on that Committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. Draft International Standards adopted
6、 by the Technical Committees are circulated to the Member Bodies for approval before their acceptance as International Standards by the IS0 Council. Prior to 1972, the results of the work of the Technical Committees were published as IS0 Recommendations; these documents are now in the process of bei
7、ng transformed into International Standards. As part of this process, Technical Committee ISO/TC 47 has reviewed IS0 Recommendation R 805 and fount it technically suitable for transformation. International Standard IS0 805 therefore replaces IS0 Recommendation R 805-1968 to which it is technically i
8、dentical. IS0 Recommendation R 805 was approved by the Member Bodies of the following countries : Austria Belgium Brazil Bulgaria Canada Chile Czechoslovakia Egypt, Arab Rep. of France Germany Hungary Korea, Rep. of India Ireland Israel Italy Japan Netherlands Norway Poland Romania South Africa, Rep
9、. of Spain Sweden Switzerland Turkey United Kingdom U.S.A. U.S.S.R. Yugoslavia No Member Body expressed disapproval of the Recommendation. No Member Body disapproved the transformation of ISO/R 805 into an International Standard. 0 International Organization for Standardization, 1976 l Printed in Sw
10、itzerland Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-INTERNATIONAL STANDARD IS0 805-1976 (E) Aluminium oxide primarily used for the production of aluminium - Determi
11、nation of iron content - 1 ,I 0-Phenanthroline photometric method 1 SCOPE AND FIELD OF APPLICATION This International Standard specifies a 1 ,lO-phenanthroline photometric method for the determination of the iron content of aluminium oxide primarily used fat- the production of aluminium. The method
12、is applicable to products having an iron content, expressed as iron( Ill) oxide, equal to or greatel than 0,005 % (m/m). 2 REFERENCES IS0 802, Aluminium oxide primarily used for the production of aluminium - Preparation and storage of test samples. IS0 804, Aluminium oxide primarily used for the pro
13、duction of aluminium - Preparation of solution for analysis - Method by alkaline fusion. IS0 2927, Aluminium oxide primarily used for the production of aluminium - Sampling. 3 PRINCIPLE Preliminary reduction of iron(lll) by means of hydroxyl- ammonium chloride. Formation of the iron( I I)-1 ,lO-phen
14、anthroline complex in a buffered medium (pH value between 3,5 and 4,2). Photometric measurement of the coloured complex at a wavelength of about 510 nm. NOTE Aluminium, elements usually present in aluminium oxide (impurities) and flux do not cause interference. 4 REAGENTS During the analysis, use on
15、ly treagents of recognized analytical grade and only distilled water or water of equivalent purity. 4.1 Hydroxylammonium chloride (NH,OH.HCI), 10 g/l solution. 4.2 l,lO-Phenanthroline hydrochloride monohydrate (C, ,H,N,.HCI.H,O), 2.5 g/l solution. This reagent may be replaced by a 2,5 g/l solution o
16、f l,lO-phenanthroline monohydrate (C12HaN2.H,0). 4.3 Buffer solution, of pH 4,90. Dissolve 272 g of sodium acetate trihydrate (CH,COONa.3H20) in approximately 500 ml of water-. Add 240 ml of glacial acetic acid, p approximately I,05 g/ml, about 17,4 N. Dilute to 1 000 ml and mix. 4.4 Sodium acetate
17、trihydrate (CH,COONa,3H,O), 500 g/l solution. 4.5 Acetic acid solution. Dilute 500 ml of glacial acetic acid, p approximately I,05 g/ml, about 17,4 N, with water to 1 000 ml. 4.6 Iron, standard solution corresponding to 0,200 g of iron( I I I) oxide pet- Iitre. Pt-epat-e this solution by either- of
18、the following two methods : 4.6.1 Weigh, to the nearest 0,001 g, 0,982 g of ammonium iron sulphate hexahydrate (NH,),Fe(S04),.6H,0. Place in a beaker of suitable capacity (for example 100 ml) and dissolve in water. Add 20 ml of a solution of sulphuric acid, p approximately I,84 g/ml, allow to cool,
19、transfer the solution quantitatively to a 1 000 ml one-mark volumetric flask, dilute to the mark and mix. 1 ml of this standard solution contains 0,200 mg of Fe203. 4.6.2 Weigh, to the nearest 0,001 g, 0,200 g of iron(lll) oxide previously ignited at 600 “C and allowed to cool in a desiccator. Place
20、 it in a beaker of suitable capacity (fat example 100 ml), add 10 ml of a hydrochloric acid solution, p appl-oximately 1.19 g/ml, and heat gently until it IS completely dissolved. Allow to cool, transfer the solution quantitatively to a 1 000 ml one-mark volumett-lc flask, dilute to the mark and mix
21、. 1 ml of this standard solution contains 0,200 mg of Fe,O,. 4.7 Iron, standard solution corresponding to 0,010 g of iron(lll) oxide pet- litre. Transfer 50.0 ml of the standard iron solution (4.6) to a 1 000 ml one-mark volumetric flask, dilute to the malk and mix. 1 ml of this standard solution co
22、ntains 0,010 mg of Fe,O,. Prepat-e this solution just before use. 1 Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IS0 805-1976 (El 4.8 pH paper, covering the pH range 3
23、,5 to 4.2 at intervals of 0.2 unit. 5 APPARATUS Ordinary laboratory apparatus and 5.1 pH meter. 5.2 Spectrophotometer, or 5.3 Photoelectric absorptiometer, fitted with filters ensuring a maximum transmission between 500 and 520 nm. 6 PROCEDURE 6.1 Aliquot portion of principal solution (test portion)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO8051976ALUMINIUMOXIDEPRIMARILYUSEDFORTHEPRODUCTIONOFALUMINIUMDETERMINATIONOFIRONCONTENT110PHENANTHROLINEPHOTOMETRICMETHOD

链接地址:http://www.mydoc123.com/p-1255714.html