ISO 7240-6-2011 Fire detection and alarm systems - Part 6 Carbon monoxide fire detectors using electro-chemical cells《火灾探测和报警系统 第6部分 用电化学电池的一氧化碳火灾探测器》.pdf
《ISO 7240-6-2011 Fire detection and alarm systems - Part 6 Carbon monoxide fire detectors using electro-chemical cells《火灾探测和报警系统 第6部分 用电化学电池的一氧化碳火灾探测器》.pdf》由会员分享,可在线阅读,更多相关《ISO 7240-6-2011 Fire detection and alarm systems - Part 6 Carbon monoxide fire detectors using electro-chemical cells《火灾探测和报警系统 第6部分 用电化学电池的一氧化碳火灾探测器》.pdf(52页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ISO 7240-6:2011(E) ISO 2011INTERNATIONAL STANDARD ISO 7240-6 Second edition 2011-06-15 Fire detection and alarm systems Part 6: Carbon monoxide fire detectors using electro-chemical cells Systmes de dtection et dalarme dincendie Partie 6: Dtecteurs de monoxyde de carbone pour la dt
2、ection dincendie utilisant des cellules lectro-chimiques ISO 7240-6:2011(E) COPYRIGHT PROTECTED DOCUMENT ISO 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying a
3、nd microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland i
4、i ISO 2011 All rights reservedISO 7240-6:2011(E) ISO 2011 All rights reserved iiiContents Page Foreword .v Introduction.vii 1 Scope1 2 Normative references1 3 Terms and definitions .2 4 Requirements.2 4.1 Compliance 2 4.2 Individual alarm indication .2 4.3 Connection of ancillary devices 2 4.4 Monit
5、oring of detachable detectors 2 4.5 Manufacturers adjustments.2 4.6 On-site adjustment of response behaviour 3 4.7 Rate-sensitive response behaviour.3 4.8 Marking.3 4.9 Data.4 4.10 Requirements for software controlled detectors .4 5 Test methods .5 5.1 General .5 5.2 Repeatability 8 5.3 Directional
6、dependence9 5.4 Reproducibility 9 5.5 Exposure to chemical agents at environmental concentrations10 5.6 Long-term stability 11 5.7 Saturation.11 5.8 Exposure to chemical agents that can be present during a fire 12 5.9 Variation in supply parameters13 5.10 Air movement.13 5.11 Dry heat (operational)
7、.14 5.12 Cold (operational)15 5.13 Damp heat cyclic (operational) 16 5.14 Damp heat, steady state (endurance)17 5.15 Low humidity, steady state (endurance).17 5.16 Sulfur dioxide (SO 2 ) corrosion (endurance).18 5.17 Shock (operational) .19 5.18 Impact (operational) 20 5.19 Vibration, sinusoidal (op
8、erational) 21 5.20 Vibration, sinusoidal (endurance) .22 5.21 Electromagnetic compatibility (EMC) immunity test (operational) 23 5.22 Fire sensitivity .23 6 Test report25 Annex A (normative) Gas test chamber for response threshold value and cross-sensitivity measurements .26 Annex B (normative) Appa
9、ratus for impact test27 Annex C (normative) Fire test room29 Annex D (normative) Smouldering (pyrolysis) wood fire (TF2) .31 Annex E (normative) Glowing smouldering cotton fire (TF3) 34 ISO 7240-6:2011(E) iv ISO 2011 All rights reservedAnnex F (normative) Deep-seated smouldering cotton fire (TF9)37
10、Annex G (informative) Information concerning the construction of the gas test chamber.40 Bibliography 42 ISO 7240-6:2011(E) ISO 2011 All rights reserved vForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The
11、work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-gover
12、nmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. Th
13、e main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote
14、. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 7240-6 was prepared by Technical Committee ISO/TC 21, Equipment for fire protection and fire fi
15、ghting, Subcommittee SC 3, Fire detection and alarm systems. This second edition cancels and replaces the first edition (ISO 7240-6:2004), which has been technically revised. ISO 7240 consists of the following parts, under the general title Fire detection and alarm systems: Part 1: General and defin
16、itions Part 2: Control and indicating equipment Part 3: Audible alarm devices Part 4: Power supply equipment Part 5: Point-type heat detectors Part 6: Carbon monoxide fire detectors using electro-chemical cells Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization
17、 Part 8: Carbon monoxide fire detectors using an electro-chemical cell in combination with a heat sensor Part 9: Test fires for fire detectors Technical Specification Part 10: Point-type flame detectors Part 11: Manual call points Part 12: Line type smoke detectors using a transmitted optical beam P
18、art 13: Compatibility assessment of system components ISO 7240-6:2011(E) vi ISO 2011 All rights reserved Part 14: Guidelines for drafting codes of practice for design, installation and use of fire detection and fire alarm systems in and around buildings Technical Report Part 15: Point type fire dete
19、ctors using scattered light, transmitted light or ionization sensors in combination with a heat sensor Part 16: Sound system control and indicating equipment Part 17: Short-circuit isolators Part 18: Input/output devices Part 19: Design, installation, commissioning and service of sound systems for e
20、mergency purposes Part 20: Aspirating smoke detectors Part 21: Routing equipment Part 22: Smoke-detection equipment for ducts Part 24: Sound-system loudspeakers Part 25: Components using radio transmission paths Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionizat
21、ion smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat sensor Part 28: Fire protection control equipment A part 23 dealing with visual alarm devices and a part 29 dealing with video fire detectors are under development. ISO 7240-6:2011(E) ISO 2011 All rights reserved viiIntroduc
22、tion This part of ISO 7240 has been drawn up by ISO/TC 21/SC 3 and is based on a standard prepared by Standards Australia International Technical Committee FP-002 “Fire detection, warning, control and intercom systems”. A fire detection and fire alarm system is required to function satisfactorily no
23、t only in the event of a fire, but also during and after exposure to conditions that the system is likely to meet in practice, such as corrosion, vibration, direct impact, indirect shock and electromagnetic interference. Some tests specified are intended to assess the performance of the fire detecto
24、rs under such conditions. The performance of fire detectors is assessed from results obtained in specific tests; this part of ISO 7240 is not intended to place any other restrictions on the design and construction of such detectors. Carbon monoxide (CO) fire detectors can react promptly to slow, smo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO724062011FIREDETECTIONANDALARMSYSTEMSPART6CARBONMONOXIDEFIREDETECTORSUSINGELECTROCHEMICALCELLS 火灾

链接地址:http://www.mydoc123.com/p-1255249.html