《IEEE C95 1 INT 1-2009 en Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz《IEEE Std C95 1 -2005用IEEE标准解释文件.pdf》由会员分享,可在线阅读,更多相关《IEEE C95 1 INT 1-2009 en Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz《IEEE Std C95 1 -2005用IEEE标准解释文件.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Standards InterpretationsforIEEE Std C95.1 -2005IEEE Standard for Safety Levels with Respectto Human Exposure to Radio FrequencyElectromagnetic Fields, 3 kHz to 300 GHzCopyright 2009 by the Institute of Electrical and Electronics Engineers, Inc.Three Park AvenueNew York, New York 10016-5997 USA
2、All Rights Reserved.This is an interpretation of IEEE Std C95.1-2005. Interpretations are issued to explain and clarify the intent of astandard and are not intended to constitute an alteration to the original standard or to supply consultinginformation. Permission is hereby granted to download and p
3、rint one copy of this document. Individuals seekingpermission to reproduce and/or distribute this document in its entirety or portions of this document must contactthe IEEE Standards Department for the appropriate license. Use of the information contained in this document isat your own risk.IEEE Sta
4、ndards DepartmentCopyrights and Permissions445 Hoes Lane, P. O. Box 1331Piscataway, New Jersey 08855-1331, USANovember 2009Interpretation Request #1Please clarify the following portions of this standard:1. On page 28 of IEEE Std C95.1-2005, 4.6, it states “Relaxation of the power density MPE for loc
5、alisedexposures.“ We are not sure if this standard is applicable if the RF radiating devices is 0.1m from the humanbody. Can this standard be applied, using the relaxation of power density MPE?2. On page 29 of IEEE Std C95. last paragraph of 4.7, it states that “A practical guideline for eliminating
6、 theneed to assess whether the whole body average SAR exceeds the basic restriction of 0.4W/kg (or 0.08 W/kg) isto determine if the power of the sources(s) exceeds 28W (upper tier) or 5.6W (lower tier) for an average man(70kg).“ It is not clear how to interpret this statement. If each individual RF
7、source passes their full body SAR,can their individual measured SAR be totaled and ensure that they do not exceed 0.4W/kg or 28W (based on11/13/2009 IEEE Std C95.1-2005standards.ieee.org/C95.1-2005.html 1/370kg for average person)?Interpretation Response #1An interpretation of IEEE Std C95.1-2005 ha
8、s been requested regarding:1. Relaxation of the power density maximum permissible exposure (MPE) for localized exposures(4.6).2. The assessment of the basic restriction based upon the power of the sources (4.7).Subclause 4.6 (relaxation of the power density MPEs for localized exposures) states, in p
9、art, “Compliance withthe MPE of Table 8 (upper tier) is determined from spatial averages of power density or the mean squaredelectric and magnetic field strengths over an area equivalent to the vertical cross section of the human body(projected area) at a distance no closer than 0.2 meters from the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC951INT12009ENSAFETYLEVELSWITHRESPECTTOHUMANEXPOSURETORADIOFREQUENCYELECTROMAGNETICFIELDS3KHZTO300GHZIEEESTDC9512005

链接地址:http://www.mydoc123.com/p-1249309.html