IEEE C93 1-1999 en Requirements for Power-Line Carrier Coupling Capacitors and Coupling Capacitor Voltage Transformers (CCVT).pdf
《IEEE C93 1-1999 en Requirements for Power-Line Carrier Coupling Capacitors and Coupling Capacitor Voltage Transformers (CCVT).pdf》由会员分享,可在线阅读,更多相关《IEEE C93 1-1999 en Requirements for Power-Line Carrier Coupling Capacitors and Coupling Capacitor Voltage Transformers (CCVT).pdf(47页珍藏版)》请在麦多课文档分享上搜索。
1、The Institute of Electrical and Electronics Engineers, Inc.3 Park Avenue, New York, NY 10016-5997, USACopyright 2004 by the Institute of Electrical and Electronics Engineers, Inc.All rights reserved. Printed in the United States of America.IEEE is a registered trademark in the U.S. Patent their exis
2、tence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no cir
3、cumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations shall be addressed to the secr
4、etariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard n
5、o later than five years from the date of approval. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 N. 17th Street, Rosslyn, Virg
6、inia 22209 Copyright O 1999 National Electrical Manufacturers Association All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or othennrise, without prior written permission of the publisher. Printed in the United States of America II Con
7、tents Foreword . v 1 Scope 1 2 Referenced and related standards 1 2.1 Referenced American National Standards 1 2.2 Other referenced standards . 1 2.3 Related standards 2 3 Definitions . 2 4 Service conditions . 6 4.1 Usual service conditions . 6 4.2 Unusual service conditions . 6 5.1 General 6 5 Rat
8、ings 6 5.2 Relaying service CCVTs 14 5.3 Metering service CCVTs . 14 6 Testing . 16 6.1 General . 16 6.2 Design test procedures . 17 6.3 Production test procedures . 30 7 Manufacturing requirements 32 7.1 Mounting ., 32 . 7.2 Nameplate markings 32 7.3 Certificate of test . 33 7.4 Symbols 33 7.5 Pola
9、rity and terminal marking . 33 7.6 Safety devices 34 7.7 High-voltage terminal . 35 Figures . 1 Circuit diagram of burden to be used for transient response test 12 2 Limits for accuracy class 1.2R for coupling capacitor voltage transformers 3 for relaying service 15 Limits for accuracy classes 0.3,
10、0.6, and 1.2 for coupling capacitor voltage transformers for metering service . 15 4 .Transient response test circuits 29 Tables 9 10 Upper ambient temperature limit 6 Dielectric strength correction factors 6 Radio-influence voltage 9 Burdens for accuracy rating 11 Burdens for transient response rat
11、ings . 12 Accuracy class limits for relaying service . 13 Limits of ratio correction factor and phase angle with voltage variations for Voltage ratings, dielectric strengths, leakage distances, and marked ratios 8 relaying service 13 Duration of induced-potential. test . 31 Coupling capacitor voltag
12、e transformer symbols . 34 iii STDONEMA C93-L-ENGL L999 W 6470247 0523175 265 m ANSVNEMA C93.1-1999 Annexes A Coupling capacitor and CCVT circuit diagrams . . 37 B Calculation of CCVT ratio and phase angle from known zero and C rated burden data . 39 Drain coil loading in power line carrier coupling
13、 circuits . 41 Figures Al Coupling capacitor with carrier accessories . _. . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . .37 A2 Typical coupling capacitor voltage transformer with carrier coupling accessories . _. 38 Cl Typical line tuner coupling capacitor connection 42 IV S
14、TD-NEMA C73.L-ENGL 1777 9 611702117 0523176 m ANSVNEMA C93.1-1999 Foreword (This Foreword is not part of American National Standard ANSINEMA C93.1-1999) This document was developed by Accredited Standards Committee C93, Power-Line Carrier Equipment and Coupling Capacitor Voltage Transformers. During
15、 the development of the standard, the Committee considered input from a balanced group representing consumer, producer, and general-interest viewpoints, which it harmonized and integrated into the standard in its present, approved form. Accredited Standards Committee C93 was established to coordinat
16、e, revise, and update the existing documents into an effective group of American National Standards, including this standard for coupling capacitors and CCVTs. A separate standard will be developed to cover each type of equipment described in the Committee scope. This standard is related to American
17、 National Standard Requirements for Power-Line Carrier Line Traps, ANSVNEMA C93.3, and American National Standard Requirements for Power-Line Carrier Line Tuning Equipment, ANSVNEMA C93.4. It is recognized that there are no requirements for ferroresonance suppression or primary short-circuit transie
18、nt response; however, the recommended test procedures are given in 6.2.16 and 6.2.17 of the standard. If meaningful requirements are determined by the industry, they will be adopted in future revisions of this standard. For metering service coupling capacitor voltage transformers, this standard alig
19、ns with American National Standard Requirements for Instrument Transformers, ANSI C57.13, where applicable. Suggestions for improvement of this standard will be welcome. They should be sent to the Secretary, ASC C93, c/o National Electrical Manufacturers Association, 1300 North 17th Street, Suite 18
20、47, Rosslyn, VA 22209. This standard was processed and approved for submittal to ANSI by Accredited Standards Committee on Power-Line Carrier Equipment and Coupling Capacitor Voltage Transformers, C93. Committee approval of the standard does not necessarily imply that all members voted for its appro
21、val. At the time it approved this standard, the C93 committee had the following members: Walter Seamon, Chairman Khaled Masri, Secretary Organization Represented Name of Representative Edison Electric Institute James Benton Gary Miller (Alternate) Robert Morton Institute of Electrical the maximum pe
22、rmissible temperature for 80C-rise transformers and reactors shall be 350C. Table 5 - Burdens for accuracy rating * These burden designations have no significance at frequencies other than 60 Hz. 11 STD-NEMA C53.L-ENGL L999 m b4702117 0523388 533 111 ANSllNEMA C93.1-1999 Table 6 - Burdens for transi
23、ent response ratings Designation X, (ohms) R, (ohms) R, (ohms) Power factor Volt-amperes At 100% burden: ZT 51.3 29.6 66 0.85 400 ZZT 102.5 59.2 131.9 0.85 200 At 25% burden: z“/4 205 118.4 263.8 0.85 1 O0 m14 410.1 236.7 527.6 0.85 50 1 RP t -Figure 1 - Circuit diagram of burden to be used for tran
24、sient response test 5.1 .I 3 Ferroresonance suppression Meaningful suppression requirements have not been determined at this time. The test method for determining ferroresonance suppression of a CCVT is given in 6.2.16. 5.1.14 Primary short-circuit transient response Meaningful primary short-circuit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC9311999ENREQUIREMENTSFORPOWERLINECARRIERCOUPLINGCAPACITORSANDCOUPLINGCAPACITORVOLTAGETRANSFORMERSCCVTPDF

链接地址:http://www.mydoc123.com/p-1249305.html